Laserfiche WebLink
be transported to the first saturated zone of the aquifer. Based on the predicted depth <br />to water of 113 feet, significant nitrate reduction is anticipated. <br />Clay soils, like those found on this Site, tend to inhibit downward movement of nitrate <br />due to adsorption of the nitrate ions to the soil. <br />Sources of Nitrate <br />Dairies, orchards that require fertilization in sandy soils, and septic systems have been <br />found to be the most significant sources of nitrate in ground water. Many orchards are <br />located in the area surrounding the Site. <br />Percolating Recharge Waters <br />One of the most determinant factors in the Hantzsche and Finnemore equation is the <br />rate of recharge from percolating waters, which mix with the downward-percolating <br />effluent generated by on-site septic systems. In the original Hantzsche and Finnemore <br />paper, "average recharge rate of rainfall" was utilized. <br />Based on San Joaquin County Environmental Health Department policy (personal <br />communication, March 18, 2019), the recharge input for the Hantzsche and Finnemore <br />equation should be derived from average monthly precipitation of rainfall and <br />evapotranspiration rates for the area; the data should be obtained from the California <br />Irrigation Management Information System (CIMIS), preferably from stations located <br />within San Joaquin County. Recharge is calculated by first determining whether the <br />average monthly precipitation exceeds average monthly potential evapotranspiration. If <br />so, then the difference is the percolating recharge water into the aquifer. Runoff and <br />stream infiltration drainage are not factored into the calculation. This approach likely <br />under-estimates recharge to the aquifer and, consequently, over-estimates nitrate <br />loading. <br />The San Joaquin County CIMIS station closest to the Site is Manteca (station 70). Data <br />for the Manteca station were available from 2014 through 2020; based on the <br />calculation shown, the estimated rate of recharge from percolating waters for the <br />Manteca station is determined to be 3.23 inches (Plate 13). A statistical error of 58 <br />percent is associated with this value. <br />Quality of Rainwater <br />Hantzsche and Finnemore listed 1 mg/L-N as the nitrate concentration of rainwater for <br />their original calculation; in the past, Live Oak has also utilized this value for the nitrate <br />loading calculation. <br />To determine a more accurate local value, Live Oak has collected rainwater during <br />several recent storm events in Lodi. Each sample was collected in a clean, dry, <br />LOGE 2148 Page 9