My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
2510
>
2300 - Underground Storage Tank Program
>
PR0547192
>
INSTALL_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:30 PM
Creation date
11/9/2021 8:52:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2021
RECORD_ID
PR0547192
PE
2351
FACILITY_ID
FA0026782
FACILITY_NAME
ARCO AM/PM - BP FUEL DISPENSING FACILITY
STREET_NUMBER
2510
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95205
APN
17130024
CURRENT_STATUS
03
SITE_LOCATION
2510 S HWY 99
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
218
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Veeder-Root Line Leak Application Guide <br /> TLS-350 Consoles - PLLD <br /> Hardware Required for PLLD Leak Detection <br /> PRESSURIZED LINE LEAK DETECTOR (PLLD) <br /> Order one per line. <br /> MODEL NO, REM <br /> 848480-003 PRESSURIZED LINE LEAK DETECTOR WITH SWIFTCHECK VALVE <br /> 848480-001 PRESSURIZED LINE LEAK DETECTOR WITHOUT SWIFTCHECK VALVE <br /> PLLD MODULES <br /> •TL6-350/TLS-350 PlusrrLS-35OR Consoles - Leak Detection for up to 6 Lines <br /> One Pressurized Line Leak Detector Interface Module is required per console. Order PLLD Controller modules as required <br /> one Controller module monitors up to 3 lines. <br /> MODEL N0, ITEM <br /> 330843-001 SIX INPUT PRESSURIZED LINE LEAK INTERFACE MODULE (MAXIMUM 1 PER CONSOLE) <br /> 330374-001 PRESSURIZED LINE LEAK CONTROLLER MODULE (MAXIMUM 2 PER CONSOLE) <br /> •TLS-350J Consoles - Leak Detection for up to 4 Lines <br /> One 'J' PLLD Interface Module is required per console. Order PLLD Controller modules as required - one Controller module <br /> monitors up to 3 lines. <br /> MODEL NO. ITEM <br /> 330843-002 'X PLLD INTERFACE MODULE (MAXIMUM 1 PER CONSOLE) <br /> 330374-001 PRESSURIZED LINE LEAK CONTROLLER MODULE (MAXIMUM 2 PER CONSOLE) <br /> PLLD PRECISION TESTING SOFTWARE MODULE <br /> Precision line leak detection capability (0.2 gph / 0. 1 gph) requires one SEM (Software Enhancement Module) for the console <br /> that must be ordered separately from the table below. Not required for 3.0 gph-only line leak detection capability. <br /> TLS-350/TLS-350J/ TLS45OR <br /> TLS-35OPLUS/TLS-350R WITHOUT BIR WITH BIR <br /> TESTING OPTION (SEM P/H) (SEM P/N) <br /> ULTIMATE TESTING 330160-010 330160-110 <br /> RISKMANAGEMENT 330160-060 330160-160 <br /> BASE COMPLIANCE 330160-050 330160-150 <br /> 3.0 GPH INCLUDED' INCLUDED' <br /> 'A SEM is not required for 3 GPH-only testing. <br /> PLLD Precision Testing Frequencies <br /> ON-DEMAND (D) <br /> Testing can be initiated manually through the TLS Console. <br /> AUTO (A) <br /> Tests will run repetitively until a passing test is achieved. Once a passing test is achieved, testing will stop and recom- <br /> mence six months from the date of the last passing test. <br /> MONTHLY (M) <br /> Tests will run repetitively until a passing test is achieved. Once a passing test is achieved, testing will stop and recom- <br /> mence the first calendar day of the next month. <br /> REPETITIVE (R) <br /> Tests will run repetitively according to pre-programmed time intervals. <br /> Refer to the matrix below to determine which precision testing option best meets your needs: <br /> 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.