My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
2510
>
2300 - Underground Storage Tank Program
>
PR0547192
>
INSTALL_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:30 PM
Creation date
11/9/2021 8:52:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2021
RECORD_ID
PR0547192
PE
2351
FACILITY_ID
FA0026782
FACILITY_NAME
ARCO AM/PM - BP FUEL DISPENSING FACILITY
STREET_NUMBER
2510
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95205
APN
17130024
CURRENT_STATUS
03
SITE_LOCATION
2510 S HWY 99
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
218
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
moi) VEEDER- ROOT <br /> Secondary - <br /> maximizeSimplify compliance and protection with a vacuum m . . - 1 secondary <br /> The Importance of SCVS IF <br /> The Secondary Containment Vacuum Sensing System _ <br /> (SCVS) for the TLS-45OPWS Automatic Tank Gauge (ATG) _ <br /> is designed to detect leaks In double-walled fuel tank, <br /> sump and piping systems. It helps contain the release of <br /> product while under vacuum. <br /> ► SYSTEM REQUIREMENTS ► FEATURES AND BENEFITS <br /> • Vacuum Sensors connect to tank, sump and piping interstices. SATISFY REGULATIONS <br /> Each Vacuum Sensor must have an associated Liquid Sensor, which <br /> is included in the pre-assembled Vacuum Sensor Monitoring Kits. ' Certified to meet California's requirement for secondary containment <br /> • Vacuum source - Submersible Turbine Pump (STP) to create suction. monitoring for tanks and lines as required by AB 2481 <br /> • Atmospheric Pressure Sensor (ATM) for measuring ambient pressure. • Satisfies the requirements for Class 1 Leak Detection as defined by the <br /> • Universal Sensor Module (USM) for sensor Inputs. European Standard EN 13160-2 <br /> • Universal Input / Output Module (UIOM) for pump control. REDUCE EXPOSURE TO RISK <br /> In certain markets, monthly inspections and three-year sump integrity • TLS-450PLUS alarms when the vacuum cannot be maintained or when <br /> tests are not required when the Veeder-Root Secondary Containment replenish rates exceed 85 liters per hour <br /> Vacuum Sensing System is used. • The system alarms when liquid is detected in the secondary space <br /> Facilitates periodic operability testing <br /> The Vacuum Sensors are connected to a TLS-450PLUS ATG, via <br /> intrinsically safe (IS) wiring. The TLS-45OPWS provides system status, <br /> replenish rates, alarms and diagnostic information. <br /> The Vacuum Sensors are manufactured in mountable kits of 1 to 4 <br /> sensors available for monitoring: -- -' <br /> Double-walled sump and piping Interstices <br /> • Double-walled steel tanks <br /> • Double-walled fiberglass tanks <br /> An inline kit mounted Liquid Sensor is used for Vacuum Sensors <br /> monitoring sumps and piping. An external Liquid Sensor (to be installed <br /> at the bottom of the tank interstice) is provided with Vacuum Sensors LEVERAGE EXISTING VEEDER-ROOT SYSTEMS <br /> for steel and fiberglass tank kits. <br /> • Uses Red Jackefr STP as the vacuum source <br /> • Installs in the STP sump <br /> • Able to share wiring conduit with other Veeder-Root intrinsically safe (IS) <br /> probes and sensors, Including sump and line leak sensors <br /> • Provides for positive shutdown of pressurized lines when required <br /> • Simple installation, no need to mess with brine <br /> www.veeder. com <br />
The URL can be used to link to this page
Your browser does not support the video tag.