<br /> SITE PLAN GENERAL NOTES INDEX OF DRAWINGS
<br /> 1. CONTRACTOR SHALL NOTIFY THE OWNER IMMEDIATELY OF DISCREPANCIES FOUND ON THE
<br /> 00 DRAWINGS, OR ANY EXISTING CONDITIONS FOUND ON SITE, WHICH CONFLICT WITH THE ocp•"!! ., San Joaquin County N
<br /> N CONTRACT DOCUMENTS. THE CONTRACTOR IS TO CLARIFY ANY SUCH DISCREPANCIES WITH - �y Environmental Health Department CID
<br /> z:
<br /> / THE OWNER PRIOR TO COMMENCING WORK. . < 1868 E. Hazelton Ave.
<br /> L 2. DRAWINGS ARE NOT TO BE SCALED. DIMENSIONS INDICATED ON DRAWINGS TAKE PRECEDENCE. Stockton, CA 95205 CD
<br /> T
<br /> LARGER SCALE DRAWINGS TAKE PRECEDENCE OVER SMALLER SCALE DRAWINGS.
<br /> U (209) 468-3420
<br /> ��r \
<br /> 3. ALL CONSTRUCTION SHALL COMPLY WITH APPLICABLE BUILDING CODES AND LOCAL F p��
<br /> RESTRICTIONS. CONTRACTORS MUST COMPLY WITH CONTRACTOR REGISTRATION APPROVED WITH CONDITIONS
<br /> REQUIREMENTS OF ALL PLAN AUTHORITIES.
<br /> 4. APPROVED PLANS SHALL BE KEPT IN A PLAN BOX AND SHALL NOT BE USED BY WORKMEN. ALL ~
<br /> CONSTRUCTION SETS SHALL REFLECT THE SAME INFORMATION. CONTRACTOR SHALL MAINTAIN For conditions, please see approval letter dated: 5-17-21 w
<br /> ONE COMPLETE SET OF PLANS ON THE PREMISES IN GOOD CONDITION AT ALL TIMES. THIS w
<br /> SHALL INCLUDE ALL ADDENDA. BUFFALO Approved by: fCaGfe(n!?e Llt�Glai'�f Date: May 17, 2021 0
<br /> SONIC DRIVE-IN
<br /> 5. THE CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR TO STARTING '1
<br /> APPLEBEE'S LU
<br /> ANY WORK AND SHALL BE RESPONSIBLE FOR ALL WORK AND MATERIALS INCLUDING THOSE
<br /> FURNISHED BY SUBCONTRACTORS AND OWNER. cU)
<br /> 6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES WFG001 COVER SHEET INDEX OF DWGS, CODE ANALYSIS, ETC. •
<br /> WHETHER SHOWN HEREIN OR NOT AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR G002 SCOPE OF WORK, GENERAL ARCH INFO •
<br /> SHALL BEAR THE EXPENSE OF REPAIR OR REPLACEMENT OF UTILITIES OR OTHER PROPERTY w4polit z 0003 LIFE SAFETY PLAN & CALCULATIONS •
<br /> O - DAMAGED BY OPERATIONS IN CONJUNCTION WITH THE EXECUTION OF THE WORK AFTER SO w 0004 COLORED ELEVATIONS FOR REFERENCE ONLY •
<br /> CD
<br /> ��� MALL ACCESS ROAD LOCATED. AD101 DEMOLITION FLOOR PLAN _ •
<br /> GV - 7. FOR CONSTRUCTION DETAILS NOT SHOWN, USE THE MANUFACTURER'S APPROVED SHOP AD201 DEMOLITION EXTERIOR ELEVATIONS _ •
<br /> w ° "KHITIM � \ DRAWINGS/ DATA SHEETS IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS. 796 N AG L E E ROAD AD202 DEMOLITION EXTERIOR ELEVATIONS •
<br /> _ 8. PROVIDE SOLID WOOD BLOCKING IN STUD WALLS AS REQUIRED TO SUPPORT WALL MOUNTED A101 DEPICTIVE DIMENSIONED&WALL FINISH FLOOR PLAN •
<br /> EXIST o �
<br /> A104 REFLECTED CEILING PLAN •
<br /> FIXTURES, FURNISHINGS AND EQUIPMENT. J
<br /> °� Q A201 EXTERIOR ELEVATIONS • CERTIFICATION
<br /> i 1i EXISTING EXISTACCESSIBLEPATM 9. ALL CONCEALED INSULATION SHALL HAVE A FLAME SPREAD RATING OF 25 OR LESS AND A SMOKE TRACY CA 95304 A202 EXTERIOR ELEVATIONS •
<br /> BUFFALoWILD WINGS I`„ �" "•�' DEVELOPED RATING OF 450 OR LESS IN ACCORDANCE WITH ASTM E84. A203 INTERIOR ELEVATIONS •
<br /> w 6,270 SIFL 11. EXIT HARDWARE SHALL ALLOW FOR EGRESS AT ALL TIMES WITHOUT THE USE OF SPECIAL w A401 ENLARGED BAR PLAN AND ELEVATIONS •
<br /> X / -
<br /> j KNOWLEDGE OR EFFORT. (' � A403 ENLARGED RESTROOM PLAN AND ELEVATIONS •EXISTp
<br /> TENANT
<br /> VACANT I: 12. THE ARCHITECT SHALL NOT BE RESPONSIBLE FOR THE MEANS, METHODS, TECHNIQUES, `-CORPORATE STORE U A501 EXTERIOR DETAILS • �GJ�
<br /> TENANT-3,042 SF la� A502 INTERIOR AND FINISH DETAILS _ •
<br /> RED ROBIN __ \ SEQUENCES OR PROCEDURES OF CONSTRUCTION SELECTED BY CONTRACTOR. Q A503 MILLWORK DETAILS • v /� W
<br /> -% 13. THE CONTRACTOR WILL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE A601 FINISH SCHEDULE WITH ROOM FINISH SCHEDULE • G 0
<br /> r S
<br /> MHEWM / JOB SITE INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE GEN 4 TO CENTER STAGE
<br /> BUILDING FINISHES ONLY-NO SCOPE WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL * N 61
<br /> PROPOSED ON EXISTING SITE / WORKING HOURS. REMODEL GUIDE SET V21 . 1 .0
<br /> 14. FIRESTOPPING OF TWO INCH NOMINAL LUMBER SHALL BE PROVIDED TO FORM AN EFFECTIVE FULL REFRESH SCOPE OF WORK EN 09/ / a�
<br /> FIRE BARRIER BETWEEN ALL CONCEALED DRAFT OPENINGS, BOTH VERTICAL AND HORIZONTAL. a EQ101 EQUIPMENT, FURNITURE,AND FIXTURE PLAN •
<br /> 15. STRUCTURAL LUMBER EXPOSED TO THE EXTERIOR OR IN CONTACT WITH THE CONCRETE OR OF CAS'
<br /> MASONRY SHALL BE PRESSURE TREATED. w
<br /> I 16. ALL WORK SHALL COMPLY WITH FEDERAL ADAAG , STATE, AND LOCAL REQUIREMENTS. U •P101 PLUMBING FLOOR PLANS
<br /> z 04/28/2021
<br /> 21. GC SHALL VERIFY MILLWORK SHOP DRAWINGS AGAINST PLANS AND/OR FIELD CONDITIONS m P401 PLUMBING SCHEDULES •
<br /> BEFORE RELEASING FOR FABRICATION. - REGISTRATION NUMBER
<br /> 22. IN CASE OF CONFLICT IN THE CONSTRUCTION DOCS, GC TO CONTACT OWNER CM &ARCHITECT - C017261
<br /> FOR CLARIFICATION. _j ED101 ELECTRICAL DEMO PLAN •
<br /> PROJECT CONTACT INFO
<br /> BEST BUY 23. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VERIFY EXISTING SITE CONDITIONS U E101 LIGHTING PLAN • EXP DATE
<br /> AND DIMENSIONS PRIOR TO BIDDING. THE CONTRACTOR SHALL NOTIFY THE CONSTRUCTION � E201 POWER PLAN • 09/30/2021
<br /> MANAGER IMMEDIATELY OF ANY DISCREPANCIES. SUBMISSION OF A BID SHALL CONSTITUTE AN U E202 SCHEDULE&DETAILS •
<br /> LU E401 COMMUNICATIONS AND DATA PLAN • PROJECT NUMBER
<br /> ACKNOWLEDGMENT AND ACCEPTANCE OF ALL EXISTING CONDITIONS. w
<br /> COST PLUS 24. THE CONTRACTOR IS RESPONSIBLE FOR ALL COORDINATION BETWEEN SUBCONTRACTORS LANDLORD/DEVELOPER 200772
<br /> / BASED ON THE ENTIRE SET OF THESE DOCUMENTS. NO EXTRA COMPENSATION WILL BE GIVEN TO INDEX OF (•=ISSUED )
<br /> A BIDDER OR SUPPLIER WHO HAS BID FROM AN INCOMPLETE SET OF CONSTRUCTION WEST VALLEY REALTY LLC DRAWINGS KEY:
<br /> DOCUMENTS. IN CASE OF INCONSISTENCIES OR DISCREPANCIES BETWEEN DRAWINGS, GENERAL 150 GREAT NECK RD STE 304
<br /> GREAT NECK NY 11021 W
<br /> CONTRACTOR IS TO CONTACT ARCHITECT FOR CLARIFICATION. 516-773-0010 O
<br /> / LEGAL@NAMDARLLC.COM U)
<br /> HAMPTON INN FAIRFIELD INN U
<br /> TENANT
<br /> BUFFALO WILD WINGS, INC. LL.
<br /> A 3 GLENLAKE PARKWAY NE, 13TH FLO
<br /> \N2p5FR�N ATLANTA, GA 30328 SCOPE OF WORK - FULL REFRESH
<br /> CONTACT: DAN WILLENBRING 6
<br /> PHONE: (678)514-4100 REFRESH OF EXISTING BUFFALO WILD WINGS RESTAURANT. 3: J N
<br /> SCOPE OF WORK INCLUDES: Q W
<br /> • EXTERIOR UPDATES TO INCLUDE NEW SIGNAGE, PAINT EXISTING EIFS, REMOVE J < 'i (D
<br /> ARCHITECT EXISTING AWNINGS AND REPLACE WITH NEW HORIZONTAL ILLUMINATED METAL BAND, Q C O M
<br /> N RYAN PATRICK MOORE NEW FINISHES AT ENTRY TOWER- NO CHANGES TO• UP ATES TO AV PACKAGE AAND ADD D CORATIVE SSCREENEXISTIITO REAR SIDE OF SOME G BRICK. c
<br /> 01
<br /> SITE PLAN GHAARCHITECTURE/DEVELOPMENT
<br /> _ 14901 QUORUM DRIVE TV'S j >- w W
<br /> „-
<br /> Scale: 1 80,-0„ SUITE 300 UPDATES TO BAR COUNTER AND FINISHES BEHIND BAR AND NEW BAR STOOLS uj W Q Z
<br /> • NEW COUNTER TOP AT TAKEOUT AREA J 239 8884 JLU
<br /> OFFICE: (972)239 8 ' ♦ U
<br /> DALLAS, TEXAS • NEW PAINT AT INTERIOR WALLS V
<br /> EMAIL: RMOORE@GHA-ARCHITECTS.COM • RE-LAMP EXISTING LIGHT FIXTURES IN DINING AREA WITH NEW LED LAMPS Q Q
<br /> • REMOVE AND REPLACE EXISTING RESTROOM VANITY AND FAUCET WITH NEW Q V
<br /> • REMOVE AND REPLACE ALL FURNITURE TO NEW SPEC z z
<br /> • MODIFY OR REMOVE EXISTING (NON-STRUCTURAL) LOW WALL FRAMING TO 0
<br /> EXISTING ELECTRICAL/PLUMBING ENGINEER COORDINATE WITH NEW DINING FURNITURE LAYOUT U) Lu
<br /> BUFFALO WILD WINGS GHC ENGINEERS • NEW CARPET TO MATCH EXISTING - PATCH AND REPAIR EXISTING TILE- REPLACE LIKE J W
<br /> (214)915 8737 1 FAX: (972)239 5054 FOR LIKE MATERIALS (V I--
<br /> in
<br /> �,. MOBILE: (850) 624 3372 • ADD NEW INTERIOR FINISHES IN DINING AREAS (FAUX BRICK PANEL AND WOOD PANEL) LU
<br /> illk � , I� WWW.GHCENGINEERS.COM AT ACCENT WALLSill
<br /> ,r V • ADD RAISED DINING BOOTHS SEPARATING DINING FROM BAR DINING AREAS. LU
<br /> till� • UPDATE DECOR/MEMORABILIA TO NEW SPECS U.,� Odlllls Tina
<br /> U.
<br /> Sonic' NO CHANGES PROPOSED TO BACK OF HOUSE AREAS (KITCHEN, OFFICE, STORAGE, J
<br /> Extended Stay Arnviuoi WALK-IN COOLERS/FREEZERS) W
<br /> Stockton-Tracy 0
<br /> f alo Wild Wings .� O
<br /> KA
<br /> 01
<br /> .F , W W
<br /> I Plus World
<br /> AT&T Slore )t
<br /> AO Garnei
<br /> id.0 aui 10-The Squeeze Inn I
<br /> *A” UTILITY & PERMITTING CONTACT INFORMATION
<br /> ZONING DEPARTMENT:
<br /> TRACY DEV. AND ENG. SVC.
<br /> Wets Fargo AtM r
<br /> 333 CIVIC CENTER PLAZA
<br /> o TRACY, CA 95376
<br /> CONTACT: PEGGY BEEUWSAERT,
<br /> PLANNING TECHNICIAN
<br /> PHONE: (209) 831-6433/(925) 667-0885 SEE G002 FOR MORE DESCRIPTION OF SCOPE OF WORK
<br /> EMAIL: PEGGY.BEEUWSAERT@CITYOFTRACY.ORG �vV�Vv�MM ?D
<br /> N BUILDING / FIRE DEPARTMENT:
<br /> 3E NTS INITY MAP DEVELOPMENT SERVICES DEPARTMENT/ BUILDING SAFETY& FIRE PREVENTION
<br /> LORNA MASON, ADMINISTRATIVE ASSISTANT II 3 GLENLAKE PARKWAY NE
<br /> LAWANA BLUFORD, BUILDING PERMIT TECHNICIAN II NOTICE TO BIDDERS BWW DESIGN TEAM
<br /> 333 CIVIC CENTER PLAZA ATLANTA, GA 30328
<br /> TRACY, CA 95376 THE "GENERAL CONTRACTOR," ITS "SUBCONTRACTORS,"AND "VENDORS" SHALL REVIEW PHONE 678.514.4100
<br /> PHONE: (209) 831-6400 OR (209)831-6479/(209)831-6406 THE PROPOSED SITE FOR BIDDING PURPOSES AND TO FAMILIARIZE THEMSELVES WITH
<br /> EMAIL: LORNA.MASON @CITYOFTRACY.ORG /LAWANA.BLUFORD@CITYOFTRACY.ORG THE EXISTING CONDITIONS OF THE SITE AND PROPOSED SPACE. ANY DISCREPANCIES
<br /> ABBREVIATIONS HEALTH DEPARTMENT: BETWEEN THE CONSTRUCTION DOCUMENTS (DRAWINGS AND PROJECT MANUAL)AND
<br /> EXISTING CONDITIONS SHALL BE SUBMITTED IN WRITING TO THE "ARCHITECT"AND
<br /> SAN JOAQUIN COUNTY OWNER BY THE "GENERAL CONTRACTOR" FOR CLARIFICATION. BY FAILURE TO CLARIFY w N
<br /> AFF ABOVE FINISH FLOOR EA EACH LAV LAVATORY RES RESILIENT ENVIRONMENTAL HEALTH DEPARTMENT DISCREPANCIES, GC SHALL BEAR RISK AND COST, AT NO CHARGE TO OWNER TO RECTIFY. Q w
<br /> AP ACCESS PANEL EIFS EXTERIOR INSULATION LL LANDLORD, LEASE LINE REV REVISION VIDAL PEDRAZA GC AND VENDOR TO CHECK WEBSITE (MOLIOR DATA)AND CALL/EMAIL ARCHITECT IN t
<br /> ACC ACCESSIBLE AND FINISH SYSTEM LIN LINEAR R RISER SENIOR REGISTERED ENVIRONMENTAL HEALTH SPECIALIST REGARDS TO MOST RECENT DRAWINGS BEFORE ORDERING, MANUFACTURING, AND o
<br /> ACT ACOUSTICAL TILE ELEC ELECTRIC(AL) LTG LIGHTING RD ROOF DRAIN 1868 EAST HAZELTON AVENUE, GOING TO SITE.
<br /> ADH ADHESIVE EQ EQUAL RM ROOM STOCKTON, CA 95205-6232
<br /> ADJ ADJUSTABLE, ADJACENT EQUIP EQUIPMENT MAS MASONRY RO ROUGH OPENING (209)468-3420/(209)468-0334 W
<br /> AHJ AUTHORITY HAVING JURISDICTION EWC ELECTRIC WATER COOLER MATL MATERIAL RB RUBBER BASE VPEDRAZA@SJGOV.ORG
<br /> AL ALUMINUM EP ELECTRICAL PANELBOARD MAX MAXIMUM
<br /> APPD APPROVED, APPROVAL EXG EXISTING MECH MECHANICAL SCHED SCHEDULE
<br /> APPROX APPROXIMATE EXP EXPANSION MDF MEDIUM DENSITY FIBERBOARD SECT SECTION U)
<br /> ARCH ARCHITECTURAL EJ EXPANSION JOINT MTL METAL SHT SHEET VENDOR CONTACT INFORMATION CODE ANALYSIS ��+—��
<br /> ACM ASBESTOS CONTAINING MATERIAL EXT EXTERIOR MEZZ MEZZANINE SIM SIMILAR
<br /> MFR MANUFACTURER SIM OPP SIMILAR, OPPOSITE HAND10
<br /> Z
<br /> BM BEAM FIN FINISH MIN MINIMUM SWB SLOTTED WALL BOARD APPLICABLE CODES O
<br /> BTWN BETWEEN FF FINISHED FLOOR MISC MISCELLANEOUS SC SOLID CORE z CL
<br /> BLKG BLOCKING FE FIRE EXTINGUISHER MO MASONRY OPENING SPEC(S) SPECIFICATION(S) REQUIRED VENDOR: CONTACT NAME PHONE# FURNISH INSTALL BUILDING: 2019 CALIFORNIA EXISTING BUILDING CODE U
<br /> BD BOARD FEC FIRE EXTINGUISHER CABINET MTD MOUNTED SF SQUARE FEET FINISHES: PLUMBING: 2019 CALIFORNIA PLUMBING CODE w
<br /> B.O.\BO BOTTOM OF FP FIREPROOF, FIRE PROTECTION SS SOLID SURFACE
<br /> MECHANICAL: 2019 CALIFORNIA MECHANICAL CODE
<br /> BLDG BUILDING FLR FLOOR NOM NOMINAL SST/SSTL STAINLESS STEEL
<br /> FD FLOOR DRAIN NIC NOT IN CONTRACT SSV STAIN, SEAL &VARNISH ELECTRIC: 2019 CALIFORNIA ELECTRICAL CODE
<br /> CPT CARPET FLUOR FLUORESCENT NO. NUMBER STD STANDARD • DALTILE TERRIE MILLER 216.409.3153 OWNER GC ACCESSIBILITY: CHAPTER 11 B 2019 CBC -2010 ADA STANDARDS
<br /> d
<br /> CLG CEILING FRG FIBER REINFORCED GYPSUM NTS NOT TO SCALE STL STEEL • NICHIHA USA INC. MATT STEPHENSON 770.789.8228 OWNER GC FIRE : 2019 CALIFORNIA FIRE CODE Q
<br /> CL CENTER LINE FRP FIBER REINFORCED PLASTIC STRUCT STRUCTURAL O
<br /> DRAS CASES JOSH FLATTUM 507.402.4812 OWNER GC GAS: 2019 CALIFORNIA FUEL GAS CODE w
<br /> CT CERAMIC TILE FRT FIRE RETARDANT TREATED OC ON CENTER SUSP SUSPENDED • w
<br /> CLR CLEAR(ANCE) FDN FOUNDATION OCC OCCUPANT ENERGY: 2019 CALIFORNIA ENERGY CODE Z)
<br /> LIGHTING: C0
<br /> COL COLUMN FURN FURNISH OPG OPENING TD TRAFFIC DOOR CALIFORNIA GREEN BUILDING STANDARDS U)
<br /> CONC CONCRETE OPP OPPOSITE TEMP TEMPERED, TEMPERATURE, • VILLA LIGHTING RYAN ZINSELMEIER 314.633.0423 OWNER GC
<br /> CMU CONCRETE MASONRY UNITS GA GAUGE OD OUTSIDE DIAMETER TEMPORARY PLUMBING: O N CO 't U') (.0
<br /> CONST CONSTRUCTION GC GENERAL CONTRACTOR OFCI OWNER FURNISHED/CONTRACTOR THK THICK(NESS) OCCUPANCY TYPE - AREA CALCULATIONS: Z
<br /> CONT CONTINUOUS GL GLASS, GLAZING INSTALLED T&G TONGUE & GROOVE • TOTO BRAND PLUMBING FIXTURES SYSTRA HERNANDEZ 800.459.7099 GC GC (SECTION 303.3 CBC)
<br /> CJ CONTROL JOINT GB GRAB BAR OFOI OWNER FURNISHED/OWNER INSTALLED T.O./TO TOP OF GROSS BUILDING AREA 9,807 SQ FT DrawingTitle
<br /> CG CORNER GUARD GYP BD GYPSUM BOARD O.O. OPPOSITE HAND T TREAD LL ROOF CONTRACTOR: ASSEMBLY GROUP A-2 BWW LEASE AREA 6,617 SQ FT
<br /> CFLG COUNTERFLASHING OHCG OVERHEAD COILING GRILLE TYP TYPICAL REQUIRED FOR CORPORATE/APPROVED FOR FRANCHISE: EXISTING 1 HOUR DEMISING WALL PATIO (SLAB) 938 SQ FT COVER SHEET
<br /> CTSK COUNTER SINK HDW HARDWARE
<br /> HDWD HARDWOOD PT PAINT UNO UNLESS NOTED OTHERWISE HM DOORS & FRAMES, WOOD DOORS, TRAFFIC DOORS, DOOR HARDWARE, TOILET ACCESSORIES, BETWEEN ADJACENT TENANT BWW REMODEL AREA 5,109 SQ FT SITE PLAN
<br /> DEG DEGREE HT HEIGHT PNL PANEL RESTROOM WALL SIGNAGE, MIRRORS, DIAPER CHANGING STATION: EXISTING BUILDING HEIGHT- 1 STORY
<br /> DEMO DEMOLITION HDF HIGH DENSITY FIBERBOARD PBD PARTICLE BOARD VB VINYL BASE EXISTING HIGHEST PARAPET= 25'-0"
<br /> DTL/DET DETAIL HC HOLLOW CORE PTN PARTITION VCT VINYL COMPOSITION TILE • TWIN CITY HARDWARE BRENT CHUHEL 651.731.7126 OWNER GC
<br /> DIA DIAMETER H.C. HANDICAPPED PLAM PLASTIC LAMINATE VWC VINYL WALL COVERING CONSTRUCTION TYPE SEATING CALCULATIONS:
<br /> DIM DIMENSION HM HOLLOW METAL PL PLATE VERT VERTICAL NETWORK VENDOR: MAIN DINING 116 SEATS
<br /> DISP DISPENSER HB HOSE BIB PLBG PLUMBING VIF VERIFY IN FIELD TYPE V-B BAR DINING 81 SEATS
<br /> f NETWORK DESIGN BRIAN FINNVIK 763.475.7440 OWNER OWNER UNPROTECTED/FULLY SPRINKLERED BAR SEATS 13 SEATS
<br /> DWG DRAWING HORIZ HORIZONTAL PLYWD PLYWOOD VTR VENT THROUGH ROOF
<br /> DF DRINKING FOUNTAIN HR HOUR KEG STORAGE ENCLOSURE VENDOR: TOTAL INTERIOR SEATS 210 SEATS
<br /> DS DOWNSPOUT QTY QUANTITY WC WATER CLOSET PATIO SEATS 60 SEATS
<br /> INCAN INCANDESCENT QT QUARRY TILE WH WATER HEATER f CISCO-EAGLE KEEGAN MOORE 888.877.3861 GC GC TOTAL SEATS 270 SEATS
<br /> ID INSIDE DIAMETER WP WATERPROOF
<br /> INSUL INSULATION RAD RADIUS W/ WITH
<br /> INT INTERIOR REF REFER TO W/O WITHOUT G001
<br /> REQ REQUIRED WD WOOD 00 GC G
<br /> MUST INCLUDE C FURNISHED ITEMS IN THEIR BID TO OWNER