U)
<br /> 0 KEY NOTES 0 GENERAL NOTES
<br /> m
<br /> N 1. COORDINATE WITH SHEET AD201 AND AD202 FOR FULL EXTERIOR DEMOLITION SCOPE OF WORK.
<br /> 0
<br /> 1. G.C. TO REMOVE ALL FURNITURE INCLUDING, TABLES, CHAIRS, BOOTHS, BAR VERIFY THIS SCOPE WITH CONSTRUCTION MANAGER. 2. REMOVE ALL BOOTHS, TABLES, CHAIRS, DRINK RAILS, TRASH UNITS AND STOOLS ALONG WITH ALL ASSOCIATED COMPONENTS AS SHOWN UNLESS NOTED OTHERWISE ON THIS PLAN. VENDOR IS RESPONSIBLE FOR
<br /> o� STOOLS, AND BENCHES IN INDICATED AREAS. COORDINATE WITH VENDOR 15. EXISTING DOOR CONDITION TO BE RECLAD WITH PLAM OR ALTERNATE TO BE STORAGE/DISPOSAL OF EXISTING FURNITURE.
<br /> T FOR STORAGE/DISPOSAL OF ALL COMPONENTS. REPLACED WITH METAL DOOR. SEE ALTERNATES ON FLOOR PLAN
<br /> Cj 2. ALL EXISTING EQUIPMENT, FINISHES, AND FIXTURES THROUGHOUT KITCHEN, 16. EXISTING CONDITION OF ALL PLUMBING FIXTURES AND ACCESSORIES TO BE 3. G.C. TO ENSURE THAT THE ADDRESS BE MAINTAINED ON SITE DURING ALL PHASES OF CONSTRUCTION.
<br /> RESTROOMS, MANAGER'S OFFICE, AND COOLERS INCLUDING BUT NOT VERIFIED BWW CONSTRUCTION PM DURING SITE SURVEY TO CONFIRM IF 4. G.C. TO MAINTAIN EXISTING VOICE/ALARM COMMUNICATION SYSTEM THROUGH ALL PHASES OF CONSTRUCTION.
<br /> LIMITED TO FLOORING, CEILING &WALL LIGHTING, AND MECHANICAL REPLACEMENT IS NECESSARY.
<br /> EQUIPMENT, ARE TO REMAIN UNLESS OTHERWISE NOTED ON THIS PLAN. G.C. 17. EXISTING CONDITION OF ALL WOOD CHAIR RAILS AND LOW WALL CAPS TO BE 5. G.C. IS RESPONSIBLE FOR ENSURING DEMOLITION WORK SCOPE IS COORDINATED WITH NEW WORK SCOPE AND ALL PARTIES INVOLVED, INCLUDING BUT NOT LIMITED TO A/V VENDOR, EQUIPMENT VENDOR, MILLWORK
<br /> IS RESPONSIBLE TO VERIFY THE CONDITION IN THE FIELD AND PATCH AND VERIFIED BY BWW CONSTRUCTION PM DURING SITE SURVEY TO CONFIRM IF VENDOR, BWW, AND SUB CONTRACTORS.
<br /> REPAIR FINISHES AS NECESSARY. G.C. TO COORDINATE ANY TEMPORARY REPLACEMENT IS NECESSARY. 6. EXISTING LIGHTING, DIFFUSERS, CEILING, SOFFITS AND CEILING TILE TO REMAIN THROUGHOUT UNLESS NOTED OTHERWISE ON PLANS. FIX ALL BROKEN/DAMAGED FIXTURES AND REPLACE DAMAGED/BROKEN CEILING
<br /> STORAGE OF EQUIPMENT WHEN NECESSARY DURING CONSTRUCTION. 18. EXISTING PATIO FURNITURE TO REMAIN IF IN GOOD CONDITION - BWW TILE AS NECESSARY.
<br /> 3. G.C. TO REMOVE COUNTERTOP AND MENU DISPLAYS IN EXISTING TAKEOUT CONSTRUCTION PM TO VERIFY DURING SITE SURVEY. IF IN POOR CONDITION
<br /> AREA REPLACE WITH NEW SPEC- SEE EQ101. 7. UNLESS NOTED ON THIS PLAN, ALL FINISHES ARE TO REMAIN THROUGHOUT KITCHEN, COOLERS, OFFICE, AND STORAGE AREAS.
<br /> 4. EXISTING CEILING/SOFFIT/BULKHEAD TO REMAIN. REPAIR GRID AND LAY-IN 19. REMOVE THE FLOOR IN ENTRY VESTIBULE AND PREP FOR NEW FINISH. SEE
<br /> TILES/DRYWALL AS NECESSARY TO BRING TO A LIKE NEW CONDITION AND FLOOR PLAN 8. THE G.C. SHALL MAINTAIN THE WORK SITE IN AN ORDERLY MANNER, FREE OF ACCUMULATED DEBRIS WITH MATERIALS STORED IN ORDER TO MINIMIZE INTERFERENCE WITH WORK BEING PERFORMED. AT THE
<br /> PREPARE TO BE REPAINTED AS NECESSARY PER SHEET A104 AND A401. 20. BAR STOOLS REMOVED AND REPLACED WITH NEW SPEC CONCLUSION OF THE WORK THE PROJECT SHALL BE CLEANED TO BWW CONSTRUCTION MANAGEMENT SATISFACTION. CLEAR EGRESS PATHS MUST BE MAINTAINED AT ALL TIMES.
<br /> 5. G.C. TO REMOVE EXISTING CARPET FROM DINING AREA. PREPARE SLAB TO 21. EXISTING BAR COUNTERTOPS TO BE REMOVED. REPAIR ADJACENT 9. G.C. IS TO EXERCISE EXTREME CARE DURING DEMOLITION SO AS NOT TO DAMAGE OR DISRUPT ALL UTILITIES OR SPRINKLER LINES. G.C. WILL BEAR SOLE RESPONSIBILITY OF ANY SUCH DISRUPTION OR DAMAGE.
<br /> RECEIVE NEW FLOORING OR FINISH. SLAB TO BE VERIFIED FOR LEVELNESS CONSTRUCTION AND PREPARE FOR NEW LAYOUT. SALVAGE EQUIPMENT FOR
<br /> IN THE FIELD IN THAT AREA AND PREPARE PROPERLY FOR NEW FINISH. SEE RE-USE AS NOTED. TEMPORARILY STORE EQUIPMENT AS REQUIRED FOR 10. IN ORDER TO CAUSE THE LEAST AMOUNT OF INCONVENIENCE, G.C. IS TO COORDINATE WITH THE LANDLORD AS NEEDED. G.C. IS TO PROVIDE AND INSTALL ALL TEMPORARY PROTECTED MEANS OF EGRESS. TEMPORARY
<br /> FLOOR PLAN ± 1,500 SF REINSTALLATION AFTER NEW CONSTRUCTION. LIGHTING, AND ALL SAFETY DEVICES IN ACCORDANCE WITH ALL STATE AND LOCAL CODES AND LANDLORD REQUIREMENTS. G.C. TO VERIFY WORKING CONDITION OF ALL EMERGENCY EGRESS LIGHTING AND
<br /> 6. G.C. TO REMOVE A/V AS INDICATED. COORDINATE WITH VENDOR FOR 22. NOT USED EMERGENCY LIGHTING PRIOR TO SHUT DOWN.
<br /> STORAGE/DISPOSAL. SEE A104, EQ101 AND ELECTRICAL. REUSE POLE 23. SIGN VENDOR TO REMOVE EXISTING SIGNAGE FROM EXTERIOR FACADES. 11. G.C. TO REMOVE ALL CARPET. PREPARE SLAB TO RECEIVE NEW FINISHES. REFER TO SHEET A103 FOR FURTHER INFORMATION. PATCH AND REPAIR ADJACENT FINISHES AS NECESSARY. CAP EXISTING MECHANICAL,
<br /> MOUNTS WHERE POSSIBLE. G.C. TO PATCH AND REPAIR SUBSTRATE AS NECESSARY AND PREPARE FOR PLUMBING AND ELECTRICAL SERVICES BELOW SLAB AS REQUIRED, TYPICAL THROUGHOUT. ALL TILE THROUGHOUT BAR, KITCHEN, COOLERS, STORAGE, RESTROOMS, AND OFFICE TO REMAIN.
<br /> 7. EXISTING A/V TO REMAIN IF 55" OR LARGER-ADJUST HEIGHT AND LOCATION NEW REPLACEMENT SIGNAGE. REFER TO SHEET A201 AND 202 FOR FURTHER
<br /> AS SHOWN ON INTERIOR ELEVATIONS. SEE A104 AND EQ101. EXTERIOR SCOPE. IF EXISTING SIGNAGE IS GEN 4.1 STYLE OR NEWER, THE 12. STRUCTURE TO REMAIN, REPORT ANY DISCREPANCIES TO ARCHITECT PRIOR TO THE BEGINNING OF CONSTRUCTION.
<br /> 8. EXISTING BAR FOOT RAIL TO REMAIN. SEE ALTERNATE BID ITEMS ON FLOOR SIGN CABINET CAN REMAIN - REMOVE SIGN AND REPLACE WITH NEW.
<br /> PLAN. 24. SIGN VENDOR TO REFACE EXSTING RESROOM SIGN WITH NEW PANELS. 13. ALL EXISTING ELECTRICAL PANELS AND EQUIPMENT TO REMAIN UNLESS OTHERWISE NOTED. REFER TO ELECTRICAL SHEETS FOR ADDITIONAL INFORMATION. CERTIFICATION
<br /> 9. G.C. TO REMOVE MISCELLANEOUS MILLWORK THROUGHOUT SPACE AS 25. GC TO REMOVE EXTERIOR LIGHT FIXTURES THAT CONFLICT WITH NEW 14. ALL EXISTING RECEPTACLES TO REMAIN UNLESS NOTED OTHERWISE ON PLANS, REFER TO ELECTRICAL DRAWINGS. ALL PUBLIC RECEPTACLES ARE AS NOTED ON ELECTRICAL DRAWINGS, UPGRADE AS REQUIRED.
<br /> NEEDED. PATCH AND REPAIR ADJACENT FINISHES AS NECESSARY. CHANNEL FEATURE - SEE EXTERIOR ELEVATIONS
<br /> COORDINATE WITH OWNER FOR STORAGE/DISPOSAL OF MILLWORK. VERIFY 26. NOT USED 15. AT THE CONTRACTOR'S OPTION; DEMOLISH OR REMOVE MORE OR LESS EXISTING WORK, PROVIDED THAT SUCH VARIATION WILL EXPEDITE THE PROJECT AND NOT INCREASE THE EXPENSE TO THE OWNER. THESE
<br /> IN THE FIELD. 27. G.C. TO REMOVE EXISTING AWNING FRAMES AND FABRIC. PATCH AND REPAIR OPTIONS SHALL BE SUBJECT TO OWNER APPROVAL. �
<br /> 10. G.C. TO REMOVE SECTION OR ALL OF PARTIAL HEIGHT WALL WHERE WALL FINISH AS REQUIRED AND PREP FOR NEW EIFS FRAME -SEE A201 & 16. ALL ABANDONED ELECTRICAL AND TELEPHONE CONDUIT, PLUMBING LINES, DRAIN LINES, AND MECHANICAL DUCTWORK AS THE RESULT OF DEMOLITION SHALL BE REMOVED. ALL CAPPED LINES AND WIRE TO BE TAKEN
<br /> INDICATED. PATCH AND REPAIR ADJACENT AS NEEDED A202. BACK TO SOURCE. REFER TO MEP DRAWINGS FOR FULL SCOPE OF WORK.
<br /> 11. REMOVE EXISTING LIQUOR BOTTLE STEP DISPLAY-SEE A401 FOR NEW 28. EXISTING BACK BAR COUNTER TO BE REMOVED G 0 S
<br /> DISPLAY. 29. REMOVE EXISTING VANITY COUNTER, MILLWORK, FAUCETS, AND SINKS. PREP 17. G.C. IS RESPONSIBLE FOR PATCHING AND/OR REPAIRING EXISTING FLOOR SLAB AND WALLS AFTER COMPLETION OF ALL DEMOLITION AND PRIOR TO THE COMMENCEMENT OF NEW CONSTRUCTION. G.C. IS TO PATCH,
<br /> 12. EXISTING JUKE BOX TO BE RELOCATED FOR NEW FIXTURES. SEE SHEET A403. REPAIR AND LEVEL EXISTING FLOOR SLAB AND INFORM TENANT OF ALL SEVERE IRREGULARITIES IN EXISTING SLAB IMMEDIATELY. AREAS OF SAW CUTTING OF THE EXISTING SLAB TO BE REVIEWED BY THE G.C. PRIOR TO * N 61
<br /> 13. REMOVE EXISTING DISPLAY GRAPHICS AND RELOCATE SAUCE DISPLAYS. 30. CUT AWAY DRYWALL AT CORNER OF SOFFIT FOR INSTALLATION OF WOOD SHUT DOWN.
<br /> 14. EXISTING SERVER STATION MILLWORK AND EQUIPMENT TO REMAIN. BLOCKING FOR USE IN SUPPORTING TV SCREEN. SEE FLOOR PLAN. S� EN 09/
<br /> REMOVE EXISTING SERVER STATION COUNTER AND REPLACE WITH NEW. 18. G.C. IS TO NOTIFY BWW CONSTRUCTION MANAGEMENT IMMEDIATELY OF ANY SEVERE DISCREPANCIES OR IRREGULARITIES DISCOVERED DURING DEMOLITION WHICH MIGHT AFFECT THE CURRENT STORE DESIGN. ,9
<br /> REMOVE WOOD CABINET DOORS AND REPLACE WITH NEW-SEE A101. 19. SEE SHEET A104 FOR ANY LIGHTING OR CEILING ELEMENTS TO BE REMOVED. OF CAS,
<br /> 04/28/2021
<br /> REGISTRATION NUMBER
<br /> CO 17261
<br /> EXP DATE
<br /> 09/30/2021
<br /> PROJECT NUMBER
<br /> 200772
<br /> I
<br /> _ _ _ _ - ------------- - W
<br /> 18 I q I II I I I I I I I I I I I N01 0 U
<br /> r�
<br /> I III III Iq II III II II I I II III II II II II II II I I II II II II I I II II � � � �
<br /> L � � � w
<br /> - - - - - - - - - - - u _4 - - - - - - - - - - - � L- - - - - _ -I� _ _ o
<br /> III
<br /> ------ ------------ II II II7 -T� ----- -------- � N
<br /> II II ° o
<br /> PATIO 6 6 J >
<br /> I 6 ii 6 11 6 127 O O 23 O � 11 i � � J � W
<br /> 6 O 0 O/� O / �\ - - 6 CE) iii Q U
<br /> \o
<br /> F_ __k9 i � - - � - - / \o /i o- - � - - � �0 - - � r co
<br /> 18 18 r--16 - � //o/ iii m 0 M H
<br /> --- ---- -- -- I-� -- el
<br /> -- � - -- -- I- -- - --�7 II `w` I I �� I ---- - s�-- - �/-------- - -� Lu
<br /> I°�----- ----- --- -- � _- - I---- r-----____ ---- --�_- _- - -_ --_----------- -- -� W LuW
<br /> _