A1.5 EGRESS & ACCESSIBILITY PLAN12" MIN CLR ON <br />PUSH SIDE <br />60" X 54" <br />72" X 60" <br />48" X 48" <br />18" MIN CLR ON <br />PULL SIDE <br />DOOR WIDTH <br />X 48" <br />48" X 30" <br />USE: RETAIL SALES <br />AREA: 2,287 SF <br />LOAD FACTOR: 60 SF/OCC <br />OCCUPANTS:39 <br />EXITS:1 REQUIRED <br />39 OCC + 3 OCC = 42 OCC <br />1 EXIT REQUIRED <br />2 EXITS PROVIDED <br />MERCHANDISE <br />101 <br />SALES <br />102 <br />COOLER/VAULT <br />109 <br />FREEZER <br />108 <br />106 <br />ALL GENDER <br />RESTROOM #2 <br />105 <br />BACKROOM <br />104 <br />OFFICE <br />103 <br />ELECTRICAL <br />107 <br />USE: BUSINESS <br />AREA: 51 SF <br />LOAD FACTOR: 100 SF/OCC <br />OCCUPANTS: 1 <br />EXITS: 1 REQUIRED <br />TURNING RADIUS60" Ø <br />TOILET STALL60" X 59" <br />24" MIN CLR ON <br />PULL SIDE <br />DUAL DIRECTION <br />SWINGING DOOR <br />USE: UTILITY/STORAGE <br />AREA: 310 SF <br />LOAD FACTOR: 300 SF/OCC <br />OCCUPANTS: 2 <br />EXITS: 1 REQUIRED <br />2 OCC + 1 OCC = 3 OCC BCE #:Scale:Date:Drawn By:Checked By:Rev. #DateDescriptionSHEET:7-ELEVEN #411871829 N. WILSON WAY, STOCKTON, CA20744.SKAS NOTED03-25-20GUGGENHEIM PARTNERS, LLC3000 INTERNET BLVD., SUITE 570, FRISCO, TEXAS 75034PROTO 10-23-2019 <br />7043 SIP - RIGHT <br />24" MIN CLEAR ON <br />PULL SIDE60" X 60" <br />ALL GENDER <br />RESTROOM #1 <br />SINGLE DOOR EXIT <br />WIDTH 34" CLEAR <br />1 EGRESS PLAN <br />1/4" = 1'-0"FEM - CHIPS5'-8"CIG'SCIG'SITPOTPNâ‚‚ <br />Nâ‚‚2' CANDY RACK4' CANDY RACK4' CANDY RACK4'-11" <br />3'-0" <br />FLOOR <br />SPINNER: <br />SUNGLASSES <br />GLOVES <br />UMBRELLAS <br />4'-2"42'-0"BUN DRAWERWASTE <br />7'-2" <br />7'-6" <br />7'-6"4'-1"3'-10"3'-10"4'-4"5'-3"4'-8"4'-1"5'-1"SS A <br />5'-2" <br />5'-0" <br />6'-0" <br />5'-5" <br />3'-4"3'-10"3'-0"3'-0 <br />"5'-1"3'-11" <br />4' <br />- <br />1 <br />0 <br />"5'-4"70'-0"43'-4"SEXIT <br />21 <br />61'-4" MAX. TRAVEL DISTANCEEXIT <br />DOUBLE DOOR EXIT <br />WIDTH 68" CLEAR <br />2154" HIGH <br />54" HIGH <br />54" HIGH <br />36" HIGH <br />ND <br />I <br />A <br />G <br />O <br />N <br />A <br />L <br /> <br />D <br />I <br />S <br />T <br />A <br />N <br />C <br />E <br />68'-9" MAX.TRAVEL DISTANCE60'-2" MAX. TRAVEL DISTANCE <br />76'-3" MAX. TRAVEL DISTANCE13 <br />BUILDING CODE INFORMATION <br />BUILDING CODE:2019 CALIFORNIA BUILDING STANDARDS CODE <br />OCCUPANCY CLASSIFICATION:MERCANTILE GROUP - M <br />CONSTRUCTION TYPE:TYPE VB <br />SPRINKLER:NOT SPRINKLERED <br />OCCUPANCY LEGEND <br />BUILDING CODE:TOTAL SQFT <br />N/A <br />328 <br />42 <br />NON OCCUPIED SPACE PER SEC. 202 <br />DEFINITION OF OCCUPIABLE SPACE <br />MERCANTILE <br />(STORAGE, STOCK, SHIPPING AREAS) <br />BUSINESS <br />OCCUPANCY SIGNAGE NOTES: <br />SIGNS STATING THE MAXIMUM OCCUPANT CONTENT SHALL BE CONSPICUOUSLY <br />POSTED IN EACH AREA OF ASSEMBLY, ASSEMBLY ROOM, OR ROOM USED FOR <br />SIMILAR PURPOSE. <br />OCCUPANT LOAD ANALYSIS: <br />FUNCTION OCCUPANT AREA OCCUPANT <br />OF SPACE LOAD FACTOR LOAD <br />MERCANTILE/60 2,287 SF 39 <br />CASHIER <br />UTILITY/300 328 SF 2 <br />STORAGE <br />OFFICE 100 51 SF 1 <br />TOTAL 42 <br />1,906MERCANTILE/CASHIER <br />N/A <br />UTILITY - NON OCCUPIED SPACE PER <br />SEC. 202 DEFINITION OF OCCUPIABLE <br />SPACE <br />EMERGENCY EXIT LIGHTING, SEE ALSO ELECTRICAL <br />DRAWINGS <br />EXIT SIGN <br />CODE PLAN KEYED NOTES <br />CUMULATIVE NUMBER OF OCCUPANTS EXITING AN <br />AREA OR BUILDING <br />NUMBER OF OCCUPANTS EXITING AND DIRECTION <br />MANEUVERING CLEARANCE AT DOORS OR CLEAR <br />FLOOR SPACE. SEE KEY BELOW <br />XX <br />CODE PLAN LEGEND <br />XX <br />CBC SECTION 504.1, BUILDING HEIGHT AND NUMBER OF STORIES <br />ALLOWABLE BUILDING HEIGHT AND NUMBER OF STORIES SHALL BE DETERMINED <br />BASED ON THE TYPE OF CONSTRUCTION, OCCUPANCY CLASSIFICATION AND <br />AUTOMATIC SPRINKLERS. <br />*ASSUME OCCUPANCY GROUP "M" WITH TYPE VB CONSTRUCTION AND <br />NON-SPRINKLERED <br />CBC TABLE 504.3, ALLOWABLE BUILDING HEIGHT <br />MAXIMUM ALLOWABLE HEIGHT: 40 FEET <br />CBC TABLE 504.4, ALLOWABLE STORIES <br />MAXIMUM NUMBER OF STORIES: 1 STORY <br />CBC SECTION 506.1, BUILDING AREA <br />ALLOWABLE BUILDING AREA SHALL BE DETERMINED BASED ON THE TYPE OF <br />CONSTRUCTION, OCCUPANCY CLASSIFICATION, AUTOMATIC SPRINKLERS AND THE <br />AMOUNT OF BUILDING FRONTAGE ON A PUBLIC WAY. <br />CBC TABLE 506.2, ALLOWABLE BUILDING AREA <br />MAXIMUM ALLOWABLE AREA: 9,000 SQUARE FEET <br />* PROPOSED BUILDING AREA: 3,033 SQUARE FEET <br />ALLOWABLE AREA IS OK <br />CBC SECTION 602.5, TYPE V <br />TYPE V CONSTRUCTION IS THAT TYPE OF CONSTRUCTION IN WHICH THE <br />STRUCTURAL ELEMENTS, EXTERIOR WALLS AND INTERIOR WALLS ARE OF ANY <br />MATERIALS PERMITTED BY THIS CODE. <br />TABLE 601, FIRE RESISTANCE RATING FOR BUILDING ELEMENTS <br />FOR TYPE V-B CONSTRUCTION IN HOURS <br />PRIMARY STRUCTURAL FRAME: 0 <br />EXTERIOR BEARING WALLS: 0 <br />INTERIOR BEARING WALLS: 0 <br />EXTERIOR NON-BEARING WALLS: SEE TABLE 602 <br />INTERIOR NON-BEARING WALLS: 0 <br />FLOOR CONSTRUCTION: 0 <br />ROOF CONSTRUCTION: 0 <br />TABLE 602, FIRE RESISTANCE FOR EXTERIOR WALLS BASED ON FIRE SEPARATION <br />DISTANCE <br />DISTANCE CONST. TYPE OCC. GROUP RATING <br />10</=X<30 VB M 0 <br />X>/=30 VB M 0 <br />*ALL EXTERIOR WALLS HAVE A SEPARATION DISTANCE GREATER THAN 10 FEET. <br />THEREFORE, NO RATING IS REQUIRED. <br />CBC TABLE 1004.1.2, FLOOR AREAS PER OCCUPANT <br />SEE PLAN BELOW FOR OCCUPANT LOAD CALCULATIONS. <br />CBC SECTION 1006.2.1, EGRESS BASED ON OCCUPANT LOAD <br />TWO EXITS OR EXIT ACCESS DOORWAYS SHALL BE PROVIDED WHERE THE DESIGN <br />OCCUPANT LOAD OR COMMON PATH OF EGRESS TRAVEL EXCEEDS THE VALUES IN <br />TABLE 1006.2.1. <br />CBC TABLE 1006.2.1, SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY <br />A SPACE IN AN "M" OCCUPANCY WITH AN OCCUPANT LOAD OF 49 OR LESS AND A <br />MAXIMUM PATH OF EGRESS TRAVEL OF 75 FEET IS ALLOWED TO HAVE ONLY ONE <br />EXIT. <br />CBC SECTION 1008.2.1, ILLUMINATION LEVEL UNDER NORMAL POWER <br />THE MEANS OF ILLUMINATION LEVEL SHALL NOT BE LESS THAN 1 FOOTCANDLE AT <br />THE WALKING SURFACE. <br />CBC SECTION 1008.3.1, EMERGENCY POWER FOR ILLUMINATION <br />IN THE EVENT OF POWER FAILURE, AN EMERGENCY ELECTRICAL SYSTEM SHALL <br />ILLUMINATE THE FOLLOWING AREAS: <br />AISLES, CORRIDORS, EXIT ACCESS STAIRWAYS AND RAMPS. <br />CBC SECTION 1009.1, ACCESSIBLE MEANS OF EGRESS <br />ACCESSIBLE SPACES SHALL BE PROVIDED WITH NOT LESS THAN ONE ACCESSIBLE <br />MEANS OF EGRESS. WHERE MORE THAN ONE MEANS OF EGRESS ARE REQUIRED, <br />EACH ACCESSIBLE PORTION OF THE SPACE SHALL BE SERVED BY AT LEAST THE <br />SAME NUMBER AS REQUIRED BY SECTIONS 1006.2 OR 1006.3. IN ADDITION, MEANS <br />OF EGRESS SHALL ALSO COMPLY WITH THE REQUIREMENTS OF CHAPTER 11B. <br />CBC SECTION 1010.1.1, SIZE OF DOORS <br />THE MINIMUM WIDTH OF EACH DOOR OPENING SHALL BE SUFFICIENT FOR THE <br />OCCUPANT LOAD AND SHALL PROVIDE A MINIMUM CLEAR WIDTH OF 32 INCHES. <br />CBC SECTION 1010.1.2.1, DIRECTION OF SWING <br />DOORS SHALL SWING IN THE DIRECTION OF TRAVEL WHERE SERVING A ROOM OR <br />AREA CONTAINING AN OCCUPANT LOAD OF 50 OR MORE PERSONS. <br />CBC SECTION 1010.1.9, DOOR OPERATIONS <br />EGRESS DOORS SHALL BE READILY OPENABLE FROM THE EGRESS SIDE WITHOUT <br />THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. <br />CBC SECTION 1013.1, EXIT SIGNS, WHERE REQUIRED <br />EXITS AND EXIT ACCESS DOORS SHALL BE MARKED BY AN APPROVED EXIT SIGN <br />READILY VISIBLE FROM ANY DIRECTION OF TRAVEL. <br />EXCEPTION 1: EXIT SIGNS ARE NOT REQUIRED IN ROOMS OR AREAS THAT <br />REQUIRE ONLY ONE EXIT OR EXIT ACCESS. <br />CBC TABLE 1017.2, EXIT ACCESS TRAVEL DISTANCE <br />OCCUPANCY WITHOUT SPRINKLER <br /> M 200 FEET <br />CBC SECTION 11B-206.2.1 SITE ARRIVAL ROUTE <br />AT LEAST ONE ACCESSIBLE ROUTE SHALL BE PROVIDED WITHIN THE SITE FROM <br />ACCESSIBLE PARKING SPACES AND ACCESSIBLE PASSENGER DROP OFF AND <br />LOADING ZONES; PUBLIC STREETS AND SIDEWALKS; AND PUBLIC TRANSPORTATION <br />STOPS TO THE ACCESSIBLE BUILDING OR FACILITY ENTRANCE THEY SERVE. <br />EXCEPTION: AN ACCESSIBLE ROUTE SHALL NOT BE REQUIRED BETWEEN SITE <br />ARRIVAL POINTS AND THE BUILDINGS OR FACILITY ENTRANCE IF THE ONLY <br />MEANS OF ACCESS BETWEEN THEM IS A VEHICULAR WAY NOT PROVIDING <br />PEDESTRIAN ACCESS. <br />CBC SECTION 11B-206.2.2, WITHIN A SITE <br />AT LEAST ONE ACCESSIBLE ROUTE SHALL CONNECT ACCESSIBLE BUILDINGS, <br />FACILITIES, ACCESSIBLE ELEMENTS AND ACCESSIBLE SPACES THAT ARE ON THE <br />SAME SITE. <br />EXCEPTION: AN ACCESSIBLE ROUTE SHALL NOT REQUIRED BETWEEN <br />ACCESSIBLE BUILDINGS, ACCESSIBLE FACILITIES, ACCESSIBLE <br />ELEMENTS AND ACCESSIBLE SPACES IF THE ONLY MEANS OF ACCESS BETWEEN <br />THEM IS A VEHICULAR WAY NOT PROVIDING PEDESTRIAN ACCESS. <br />CPC TABLE 422.1, MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES <br />OCCUPANT LOAD FACTOR PER CPC TABLE A, OCCUPANT LOAD FACTOR: <br />C-STORE = 3,033 SQ FT <br /> TOTAL = 3,033 SQ FT <br />TOTAL OCCUPANT LOAD = 42 OCCUPANTS <br />OCCUPANCY WATER CLOSETS LAVATORIES DRINKING SERVICE <br /> FOUNTAINS SINK <br /> MALE FEMALE MALE FEMALE <br /> M 1:1-100 1:1-100 1:1-200 1:1-200 1:1-250 1 <br />OCCUPANTS: <br />42 OCCUPANTS = 21 MALE AND 21 FEMALE <br />TOTAL REQUIRED PLUMBING FIXTURES: <br />MALE = 1 WATER CLOSET AND 1 LAV <br />FEMALE = 1 WATER CLOSET AND 1 LAV <br />DRINKING FOUNTAIN = 1 <br />SERVICE SINK = 1 <br />PLUMBING FIXTURES PROVIDED: <br />MALE = 1 WATER CLOSET, 1 URINAL, AND 1 LAV <br />FEMALE = 2 WATER CLOSET AND 1 LAV <br />DRINKING FOUNTAIN = 1 (AT SODA MACHINE) <br />SERVICE SINK = 1 <br />CFC 505.1, ADDRESS IDENTIFICATION <br />NEW BUILDINGS SHALL BE PROVIDED WITH APPROVED ADDRESS IDENTIFICATION. <br />THE ADDRESS IDENTIFICATION SHALL BE PLACED IN A POSITION VISIBLE FROM THE <br />STREET FRONTING THE PROPERTY AND SHALL CONTRAST WITH THEIR <br />BACKGROUND. EACH CHARACTER SHALL BE NOT LESS THAN 4" HIGH AND NOT <br />LESS THAN 1/2" WIDE. SEE CFC 505 FOR ADDITIONAL. <br />CFC 907.2 FIRE ALARM DETECTION SYSTEMS, WHERE REQUIRED <br />AN APPROVED FIRE ALARM SYSTEM INSTALLED IN ACCORDANCE WITH THE <br />PROVISIONS OF THIS CODE AND NFPA 72 SHALL BE PROVIDED IN NEW BUILDINGS <br />AND STRUCTURES. <br />CFC 907.5, OCCUPANT NOTIFICATION SYSTEM <br />A FIRE ALARM SYSTEM SHALL ANNUNCIATE AT THE FIRE ALARM CONTROL UNIT AND <br />SHALL INITIATE OCCUPANT NOTIFICATION UPON ACTIVATION. <br />OCCUPIABLE SPACE - A ROOM OR ENCLOSED SPACE DESIGNED FOR HUMAN <br />OCCUPANCY IN WHICH INDIVIDUALS CONGREGATE FOR AMUSEMENT, <br />EDUCATIONAL OR SIMILAR PURPOSES OR IN WHICH OCCUPANTS ARE ENGAGED IN <br />LABOR, AND WHICH IS EQUIPPED WITH MEANS OF EGRESS AND LIGHT AND <br />VENTILATION FACILITIES MEETING THE REQUIREMENTS OF THIS CODE. <br />BID SET 5/26/20