Laserfiche WebLink
Kitchen Roof <br />(existing) <br />Service/ Egress <br />Hall <br />Dumbwaiter <br />Service/ Egress <br />Stair <br />Upper Level <br />Vestibule <br />Upper Level Deck <br />. <br />. <br />(2)3068store frnt Multislide <br />existing <br />Stair existing Stair <br /> to be "Demoed" <br />PHASE 02 WORK <br />PHASE 01 WORK <br />65 <br />5 <br />21 <br />19 <br />e e e <br />NO WORK REQUIRED <br />THIS AREA... <br />CONTRACTOR TO EXPOSE AND THOROUGHLY DOCUMENT UPPER LEVEL/ <br />ROOF FRAMING THIS AREA AND PROVIDE TO DESIGN PROFESSIONALS <br />FOR FINAL FRAMING ALTERATIONS AT PROPOSED ROOF NEW ROOF AND <br />ROOF EXTENSIONS... <br /> 7 <br />20 <br />(2)3068store frnt <br />Men <br />Women <br />A2.4 <br />01 <br />6 5 4 3 2 1 <br />A <br />A1 <br />B <br />C <br />A3 <br />B3 <br />1a <br />A2 <br />B2 <br />31 <br />23 <br />Service Access Deck <br />"NON-ADA COMPLIANT" <br />Portable <br />Bar <br />Proposed Changes "Clouded" <br />Overflow <br />Toilet <br />Vestibule <br />Shower <br />Brides Toilet <br />26 <br />27 <br />Brides Room <br />Multislide <br />6 <br />24 <br />25 <br />28 <br />29 <br />jmwells design <br />713 washington street <br />kerrville, texas 78028 <br />830.890.8808 <br />jmwellsdesign@gmail.com/ <br />jackmwells@outlook.com <br />C O P Y R I G H T 2 0 1 7 <br />B I N D I N G . . .D:\Jack\My Documents\Drawings\LEER CONSTRUCTION\JANOON Banquet Remodel\Janoon Tenant Improvement.dwg-- <br />A2.1 <br />18.106 <br />Floor Plan - <br />Upper LevelTenant Improvement/ Design Build112 East Yosemite AvenueManteca, CaliforniaPhase 2Janoon Banquet and Event HallProposed Floor Plan -Upper Level <br />1/8" = 1'-0"01PLAN <br />NORTH <br />H <br />G <br />G <br />L <br />P <br />P <br />P <br />P <br />F INTERIOR WALL - "FRP" EMBOSSED PANELS OVER 5/8" MOISTURE RESISTANCE GYPSUM <br />BOARD "DENSSHIELD" AT "WET" AREAS OR EQUAL OVER FRAMING AND/ OR FURRING, <br />PROVIDING A CONTINUOUS "SMOOTH" FINISHED WALL ACROSS EXISTING PILASTERS. <br /> A EXTERIOR WALL - MINIMUM 7/8 3 - COAT MASONRY STUCCO WITH ELASTOMERIC COLOR <br />COAT ON METAL LATH OVER "TYVEK" WEATHER BARRIER ON 7/16" MINIMUM EXTERIOR <br />APA RATED SHEATHING (OR "ZIP SYSTEM SHEATHING" 7/16" STRUCTURAL 1 RATED), 2X4 <br />STUD GRADE STUDS AT 16 INCHES ON CENTER MAXIMUM WITH R-13 MINIMUM BATT <br />INSULATION (PROVIDE "DENSSHIELD" OR EQUAL AT WET LOCATIONS) <br />B INTERIOR WALL - 5/8" GYPSUM BOARD OVER 2X4 STUD GRADE STUDS AT 16 INCHES ON <br />CENTER MAXIMUM WITH R-13 MINIMUM BATT INSULATION (PROVIDE "DENSSHIELD" OR <br />EQUAL AT WET LOCATIONS) <br />C INTERIOR WALL - 5/8" GYPSUM BOARD OVER 7/8" FURRING CHANNELS FASTENED TO <br />EXISTING BRICK VENEER WALL <br />D EXTERIOR WALL - MINIMUM 7/8 3 - COAT MASONRY STUCCO WITH ELASTOMERIC COLOR <br />COAT ON METAL LATH OVER "TYVEK" WEATHER BARRIER ON 7/16" MINIMUM EXTERIOR <br />APA RATED SHEATHING (OR "ZIP SYSTEM SHEATHING" 7/16" STRUCTURAL 1 RATED), 2X4 <br />STUD GRADE STUDS AT 16 INCHES ON CENTER MAXIMUM WITH R-13 MINIMUM BATT <br />INSULATION, PROVIDE 5/8 MOISTURE RESISTANCE GYPSUM BOARD "DENSSHIELD" AT <br />"WET" AREAS OR EQUAL AT INTERIOR SIDE WITH "FRP" EMBOSSED PANELS OVER. (IN-FILL <br />FRAMING AT EXISTING DOOR.) <br />E EXTERIOR WALL - MINIMUM 7/8 3 - COAT MASONRY STUCCO WITH ELASTOMERIC COLOR <br />COAT ON METAL LATH OVER "TYVEK" WEATHER BARRIER ON 7/16" MINIMUM EXTERIOR <br />APA RATED SHEATHING (OR "ZIP SYSTEM SHEATHING" 7/16" STRUCTURAL 1 RATED), 2X4 <br />MIN. STUD GRADE STUDS AT 16 INCHES ON CENTER MAXIMUM WITH R-13 MINIMUM BATT <br />INSULATION, [PROPOSED FRAMING SHALL ALLOW INTERIOR FINISHES TO ALIGN WITH <br />EXISTING FINISHED] PROVIDE 5/8 MOISTURE RESISTANCE GYPSUM BOARD "DENSSHIELD" <br />AT "WET" AREAS OR EQUAL AT INTERIOR SIDE WITH "FRP" EMBOSSED PANELS OVER. <br />(IN-FILL FRAMING AT EXISTING DOOR.) <br /> A EXTERIOR WALL - MINIMUM 7/8 3 - COAT MASONRY STUCCO WITH ELASTOMERIC COLOR <br />COAT ON METAL LATH OVER "TYVEK" WEATHER BARRIER ON 7/16" MINIMUM EXTERIOR <br />APA RATED SHEATHING (OR "ZIP SYSTEM SHEATHING" 7/16" STRUCTURAL 1 RATED), 2X4 <br />STUD GRADE STUDS AT 16 INCHES ON CENTER MAXIMUM WITH R-13 MINIMUM BATT <br />INSULATION (PROVIDE "DENSSHIELD" OR EQUAL AT WET LOCATIONS) <br />B INTERIOR WALL - 5/8" GYPSUM BOARD OVER 2X4 STUD GRADE STUDS AT 16 INCHES ON <br />CENTER MAXIMUM WITH R-13 MINIMUM BATT INSULATION (PROVIDE "DENSSHIELD" OR <br />EQUAL AT WET LOCATIONS) <br />C INTERIOR WALL - 5/8" GYPSUM BOARD OVER 7/8" FURRING CHANNELS FASTENED TO <br />EXISTING BRICK VENEER WALL <br />D EXTERIOR WALL - MINIMUM 7/8 3 - COAT MASONRY STUCCO WITH ELASTOMERIC COLOR <br />COAT ON METAL LATH OVER "TYVEK" WEATHER BARRIER ON 7/16" MINIMUM EXTERIOR <br />APA RATED SHEATHING (OR "ZIP SYSTEM SHEATHING" 7/16" STRUCTURAL 1 RATED), 2X4 <br />STUD GRADE STUDS AT 16 INCHES ON CENTER MAXIMUM WITH R-13 MINIMUM BATT <br />INSULATION, PROVIDE 5/8 MOISTURE RESISTANCE GYPSUM BOARD "DENSSHIELD" AT <br />"WET" AREAS OR EQUAL AT INTERIOR SIDE WITH "FRP" EMBOSSED PANELS OVER. (IN-FILL <br />FRAMING AT EXISTING DOOR.) <br />E EXTERIOR WALL - MINIMUM 7/8 3 - COAT MASONRY STUCCO WITH ELASTOMERIC COLOR <br />COAT ON METAL LATH OVER "TYVEK" WEATHER BARRIER ON 7/16" MINIMUM EXTERIOR <br />APA RATED SHEATHING (OR "ZIP SYSTEM SHEATHING" 7/16" STRUCTURAL 1 RATED), 2X4 <br />MIN. STUD GRADE STUDS AT 16 INCHES ON CENTER MAXIMUM WITH R-13 MINIMUM BATT <br />INSULATION, [PROPOSED FRAMING SHALL ALLOW INTERIOR FINISHES TO ALIGN WITH <br />EXISTING FINISHED] PROVIDE 5/8 MOISTURE RESISTANCE GYPSUM BOARD "DENSSHIELD" <br />AT "WET" AREAS OR EQUAL AT INTERIOR SIDE WITH "FRP" EMBOSSED PANELS OVER. <br />(IN-FILL FRAMING AT EXISTING DOOR.) <br />G EXTERIOR WALL - MINIMUM 7/8 3 - COAT MASONRY STUCCO WITH ELASTOMERIC COLOR <br />COAT ON METAL LATH OVER "TYVEK" WEATHER BARRIER ON 7/16" MINIMUM EXTERIOR <br />APA RATED SHEATHING (OR "ZIP SYSTEM SHEATHING" 7/16" STRUCTURAL 1 RATED), AT <br />EACH SIDE OF 2X6 STUD GRADE STUDS AT 16 INCHES ON CENTER MAXIMUM. <br />H EXTERIOR WALL - MINIMUM 7/8 3 - COAT MASONRY STUCCO WITH ELASTOMERIC COLOR <br />COAT ON METAL LATH OVER "TYVEK" WEATHER BARRIER ON 7/16" MINIMUM EXTERIOR <br />APA RATED SHEATHING (OR "ZIP SYSTEM SHEATHING" 7/16" STRUCTURAL 1 RATED), 2X4 <br />STUD GRADE STUDS AT 16 INCHES ON CENTER MAXIMUM WITH R-13 MINIMUM BATT <br />INSULATION, PROVIDE 5/8 GYPSUM BOARD AT INTERIOR. <br />J EXTERIOR WALL - MINIMUM 7/8 3 - COAT MASONRY STUCCO WITH ELASTOMERIC COLOR <br />COAT ON METAL LATH OVER "TYVEK" WEATHER BARRIER ON 7/16" MINIMUM EXTERIOR <br />APA RATED SHEATHING (OR "ZIP SYSTEM SHEATHING" 7/16" STRUCTURAL 1 RATED), 2X4 <br />STUD GRADE STUDS AT 16 INCHES ON CENTER MAXIMUM WITH R-13 MINIMUM BATT <br />INSULATION, PROVIDE 5/8 GYPSUM BOARD AT INTERIOR. NOTE, FRAMING MAY <br />VARY...CONTRACTOR SHALL VERIFY FRAMING AT EXISTING "HALL", PROPOSED INTERIOR <br />AND EXTERIOR FINISHES SHALL ALIGN WITH EXISTING. <br />K INTERIOR WALL - 5/8" GYPSUM BOARD OVER 2X4/ 2X6 (SEE PLAN) STUD GRADE STUDS AT <br />16 INCHES ON CENTER MAXIMUM WITH "FRP" EMBOSSED PANELS OVER 5/8" MOISTURE <br />RESISTANT GYPSUM BOARD EACH SIDE (PROVIDE "DENSSHIELD" OR EQUAL AT WET <br />LOCATIONS) (OMIT "FRP" AT DUMB WAITER SHAFT SIDE...) <br />Wall Types <br />L EXTERIOR WALL - MINIMUM 7/8 3 - COAT MASONRY STUCCO WITH ELASTOMERIC COLOR <br />COAT ON METAL LATH OVER "TYVEK" WEATHER BARRIER ON 7/16" MINIMUM EXTERIOR <br />APA RATED SHEATHING (OR "ZIP SYSTEM SHEATHING" 7/16" STRUCTURAL 1 RATED), 2X6 <br />STUD GRADE STUDS AT 16 INCHES ON CENTER MAXIMUM WITH R-13 MINIMUM BATT <br />INSULATION, PROVIDE 5/8 GYPSUM BOARD AT INTERIOR. NOTE, FRAMING MAY <br />VARY...CONTRACTOR SHALL VERIFY FRAMING AT EXISTING "HALL", PROPOSED INTERIOR <br />AND EXTERIOR FINISHES SHALL ALIGN WITH EXISTING. <br />M <br />P <br />N <br />C <br />M INTERIOR WALL - 5/8" GYPSUM BOARD OVER 2X4/ 2X6 (SEE PLAN) STUD GRADE STUDS AT <br />16 INCHES ON CENTER MAXIMUM (PROVIDE "DENSSHIELD" OR EQUAL AT WET <br />LOCATIONS) <br />N INTERIOR WALL - 5/8" GYPSUM BOARD OVER DBL 2X4 STUD GRADE STUDS AT 16 INCHES <br />ON CENTER MAXIMUM (PROVIDE "DENSSHIELD" OR EQUAL AT WET LOCATIONS) <br />INTERIOR WALL - 2 - 5/8" TYPE X GYPSUM BOARD (ea. side) ON 2X6 STUD GRADE STUDS <br />AT 16 INCHES ON CENTER MAXIMUM (UNLESS DETAILED OTHERWISE). PROVIDE "FRP" <br />EMBOSSED PANELS OVER AT KITCHEN SIDE <br /> 2x6 WOOD STUD WALL - 100% Design Load - ASTM E 119/ NFPA 251, Test Number - <br />WP-1232 (Fire Endurance), WP-1234 (Hose Stream), U304/314 2x4 studs <br />P <br />5401 N. Hickman Rd., Denair, Ca. 95316 <br />(209) 485-8620 <br />A2.4 <br />01