Laserfiche WebLink
z b � <br /> g big 5 ❑ �' � `c0 <br /> riESporting M <br /> � � N <br /> Extg service alley Extg service alley PROJECT = Q LO <br /> EXIT DOOR LANDING SITE U <br /> EXIT DOOR LANDING is level with the finished m U N <br /> is level with the finished W N <br /> floor of the tenant unit. m U <br /> floor of the tenant unit. <br /> - Jack N ❑ElCcc <br /> N the Box ^� w <br /> w t <br /> EL <br /> Mission Ridge Dr y o <br /> Extg 3'Exit door w/ Extg 3'Exit door made LO <br /> 0)panic hardware into 5'wide door w/ Evaporator Unit fl <br /> 0 pAQfN•.•�+ San Joa win Count panic hardware E Q Q Q Q ro <br /> o q Y z o Vicinity Map a <br /> (E)Pony wall to be removed M Qr' Environmental Health Department ) R Q N <br /> a� o <br /> W < 1868 E. Hazelton Ave. o.3 y <br /> =:ba.1 <br /> - - '•-1 Stockton, CA 95205 Min (N)Hall o Walk-in Cooler co a <br /> • 0 �;�° (209) 468-3420 X 69 sq.ft. c w/insulated floor <br /> W - Q ih 108 sq.ft. Storage. Tenant Business Owner: <br /> Suspended Ceiling Ht:10'-11" Kuldee Singh <br /> Suspended Ceiling Ht:10'-11" APPROVED W I H CONDITIONS 0 8'-7" 13'-6" p g <br /> Avenue <br /> Storage 4'-6" Ripon, CA 95366 n N a o <br /> For conditions, please see approval letter dated: 10/25/18 282 sq.ft. Tel: 206-359-0604 a) o o <br /> Ext 200A Main scot Sa1�9aGan9 Oct 25 2018 Em: kuldeep1592@gmail.com 5 5 Mn <br /> w `s°]-LDi <br /> g Approved by: Date , ? N N N <br /> Distribution Panel a �, y = N <br /> Extg 200A Main (5)Glass display doors Consultant: ° ° 15 o 2 <br /> /,—Distribution Panel T 6'' 3 U?1= ° ° <br /> / to remain Suspended Ceiling Ht.10'-11" / ~ Benjamin Cantu L Z) 0 = 8 _ <br /> Suspended Ceiling Ht:10'-11" N = 3 5— o <br /> BC Planningo N 6 6 ° <br /> _ o � o <br /> •o E <br /> 3'Insulated <br /> o N <br /> C, <br /> do r 829 Mellon Avenue 2 0 '3 0 0 0 <br /> 17'-10" Manteca, CA 95337 0 2 3 cL o <br /> _ a N <br /> `=—.6i <br /> Tel: 209-679-5204 y o N L E <br /> Em: bcantu@sg50.com o o = a o° E T <br /> 0 <br /> 24„24„ 55 55 11 o E <br /> _ o <br /> N N'O .�.. O = N <br /> Morink Water ° ° °.3 =U E <br /> Heater Site Info: °`_ 2 ° E <br /> Extg 125A Sub-panel 01 m o g <br /> to be removed <br /> 0 -0 Address: 1031 S Main Street <br /> ------------- w <br /> 24'-0" Q Q APN: 219-350-43 <br /> o ! Tm Size: 2.53 acres (shopping center) <br /> (Neighborhood Commercial) <br /> Water '�, Water l Wash Basin _ <br /> Suspended CeilinHt:10'-11" Sus en led Ceiling Ht:10'-11" Zone: C N (Neighborhood Commercial) <br /> e' ig <br /> Heater Heater <br /> v Extg metal structural Extg. Use: General Commercial Center <br /> Janitor/Utility 12'-8, pole(to remain) / Proposed: No change <br /> —►� Display Freezer <br /> w insulates floor Unit Area: 2,923 s ft. Gross <br /> Relocate(E) Room Q Extg mop sink and =_______= 7M 171 sq.ft. q' (Gross) <br /> Office water heater relocated <br /> water heater Extg metal structural 0 114 sq.ft. into Store Room;cap 5'-3" 3'-0" 5'-9" T-0" <br /> Storage and mop sink Extg partition to be pole(to remain) <br /> o) drain at floor level <br /> removed s'-10" 2" Main Building Code Data: Q <br /> �_ <br /> _____ <br /> 177 <br /> Land Use: Commercial Center W <br /> �: g ;, � � i° Grou Occupancy: M <br /> T-4" 3'-6" o p <br /> Ex? T N Type Const.: Type V-B W <br /> (E)3'Door to r main N ;; 2a~zea' <br /> Mop sina Allowable Stories: Two <br /> --------- <br /> a Building Stories: One O <br /> Remove extg Y door (N)3030 Fixed Extg Y door (N)3030 Fixed Allowable Floor Area: 9,000 sq.ft. <br /> opening O w/closer O c� BuildingArea Tenant 2,923 s ft. (gross) <br /> Suspended Ceiling Ht:10'-11" 1 1 (Tenant): q' <br /> Remaining suspended ceiling rid Suspended Ceiling Ht 10'-11~ <br /> g p g g � = Allowable Building Height: 40' <br /> Hall system to be repaired if necessary (E)Hall Q �A M W <br /> Doors with closers shall co Q o Building Height: 16' <br /> after removal of partitions 46 sq.ft. 2 <br /> be adjusted so that from g'-g" v Retail o Ln Fire Sprinklers: Yes <br /> 9 9 an open position of 90 1,949 sq.ft. Q Total Occupant Load: 35 <br /> (E)Y D r to remain ! degrees,the time (N)3'door ❑2 0 <br /> w <br /> required to move the <br /> Sh door to a position of 12 -- <br /> SuspendedCeilin Ht:1x-11" Occupant Load Breakdown: 2016 CBC Table 1004.1.2 <br /> (E)Lavatory f Remove(E)Lavatory; g 5 seconds minimum. is G"e5,--�("- - (Ej-Lavatory p ( ) <br /> to remain o ��cap drain in wall 6,"-� <br /> 39'0" O <br /> Extg Accessible <br /> Extg Accessible _______ _ Office: 114 sq. ft. (100) 1 <br /> Proposed Occupancy <br /> Women s Restroom 30 48"Cie- -- <br /> D , <br /> Remove ra n wallr � � ' � Me�s)RestrOlyom Unisex restroom shall Q Ressex troom <br /> '; Retail (Mercantile): 1,805 sq.ft. (60) 30 ~ <br /> The existing door to the <br /> O y room 1 Storage/Walk-ins: 708 sq.ft. (300) 2 O I� <br /> -., Remove E Lavato _ <br /> ------------------- <br /> r , i 5'x5'Clearence ' <br /> p f„� be changed to open sq;ft. Restroom: 97 sq.ft. <br /> EW Remove all extg_ -_-'_ _ _____ ca drain in wall Extg Halls: 115 sq.ft. <br /> ............ <br /> ' p into the restroom. � O <br /> cubical partitionslr� ___,- <br /> Net Occupancy 33 <br /> Extg 8'Ceiling w <br /> 5'-3" ' ^ <br /> Extgmetal structural 3'0" 3'-0° 5'6° Re wired Exits: Two 2 2016 CBC Table 1006.2.1 <br /> Extg 8'Ceiling - Q o m Extg metal structural q ( ) ( ) <br /> (E)Toilet Remove(E)Urinal; a pole(to remain) !16•-17^ (E)Toilet <br /> '! 3 pole(to remain) <br /> o �telocated <br /> to remain cap drain in wall CO .Q Urinal Exits provided: Two (2) <br /> 3 o Illustrated store gondola are f co <br /> .°N' = space allocation purpos s only o � 5 <br /> Replace extg demolished ceiling °' __ a separate permit and approval = o,� <br /> framingover the restrooms w/ s ° is required for gondolas. o w <br /> o o o Q Provide R-15 IY a <br /> suspended ceiling grid system E is in insulation in new wall v c <br /> Ns �, a N a, Project Description & Building <br /> a n O <br /> o CJ <br /> � o Compliance Notes: <br /> Remove(E)Toilet;cap 'A -' Remove(E)Toilet;cap y m <br /> drain below floor level r T-0" 4'-0" 1. This project involves the conventional <br /> drain below floor level o <br /> --- Q Gondola store tenant improvements construction of a retail U <br /> C m a ( Yp) % HB store within the existing main building <br /> c fixtures T g g <br /> y envelope. No change (structural or otherwise) <br /> Extg partition tobeto the main structure is proposed. The project QI <br /> ° removed 3'-0" will involve the removal of non-bearing � U <br /> Sink (Typ) co partitions and reduction of plumbing fixtures, w <br /> and the installation of refrigerated display <br /> cases, a walk-in cooler, display gondolas, t--� <br /> "' and minor plumbing changes. One existing I� Z <br /> Extg sink/cabinets to be removed. ADA accessible restroom will be removed and 1--1 <br /> Cap drain below floor level one will be remodeled into a single unisex <br /> accessible restroom. <br /> 2. New construction will not involve altering ~ <br /> P existing bearing walls, center columns, or <br /> ? roofing. All work occurs in the interior of the <br /> w O <br /> 6, 2 5'-0" building. <br /> 3. Work involved in the remodel shall comply v w <br /> Cap all extg shampoo sinks Suspended Ceiling Ht 10'-11" with 2016 California Building Code, 2016 w <br /> Secure Storage <br /> plumbing below floor level; o LL California Electrical Code, 2016 California <br /> Accessible 47 S ft. <br /> replace the to match extg floor a'Cashier POS s'Shelved Cashier POS o M q' Q Plumbing Code, 2016 California Mechanical H� <br /> 38"High Max. Display Case 34"High Max. ZV <br /> a Code, 2016 California Green Building <br /> z Standards Code, 2016 California Fire Code, <br /> and Building Energy Efficiency Standards. Z <br /> Suspended Ceiling Ht.,1W-11" 9 4. No change is proposed to the existing <br /> io $ `' HVAC roof mounted units and interior W <br /> Suspended Ceiling Ht:10'41" o <br /> r o <br /> N= n q @= distribution system.b Suspended Ceiling Ht.10-11^ pih 5. Property is not subject to flooding. <br /> w <br /> a" z 6. Existing topography is relatively flat. <br /> 2 7. The building has a fire sprinkler system. <br /> Plans preparation and submittal for <br /> n k modification of the existing fire sprinkler M <br /> O <br /> Extg storefront windows w/3'double doors Extg storefront windows w/3'double doors system will be conducted by others. <br /> EXIT DOOR LANDING ~ <br /> is level with the finished <br /> EXIT DOOR LANDING ENTRANCE/EXIT ENTRANCE/EXIT floor of the tenant unit. <br /> is level with the finished <br /> Existing Wall Key: floor of the tenant nit. 49r-4rr <br /> Existing partitions to remain as is. No change is proposed to <br /> Demolition Floor Plan Scale: 1/4" — 1 ,-�„ the existing HVAC equipment <br /> Existing nonbearing partition to be removed. N and distribution system. Remodeled Floor PIan Scale: 1 /4" = V-011 N Restroom Plumbing Fixtures: (2016 CPC Chap 4, Table 422.1) <br /> Roof access to the roof mounted <br /> HVAC equipment is located at the Group M(Retail): (Table A) <br /> end of the building.(See site plan.) Retail floor area 1,805 sq. ft. (200) 9.0 occupants <br /> New Windows Schedule Store office 114 sq. ft. (200) .5 occupants <br /> Storage, walk-ins 708 sq. ft. (5,000) .1 occupants <br /> No. Qty Width* Height* Type Wind Ht Material SafefyGlaz Above Fl. Panes Screen LI-value SHGC Remarks Remodeled Wall Key: (Less restroom, halls) 9.6 <br /> O2 3'-0" 3'-0" Fixed 6-8" Vinyl Yes 44" Double No 0.27 0.24 <br /> Existing partitions to remain as is. Occupant factor: 10 occupants <br /> Remodeled Room Surface Covering & Finish <br /> In accord with CBC Section 803 and ASTM E 84 or LIL7223,lobby finish materials shall comply with Class B flame spread index 26-75 and smoke developed index O 1 2'-0" T-0" Fixed U-8" Vinyl Yes 44" Double No 0.27 0.24 <br /> 0-a50;and finishmaterials inother others shall comply with Class Cflame spread index 75-200 and smoke developed index 0-450. New nonbearing partition w/ 1/2" sheetrock Existing Fixtures: Men: 1-toilet, 1-urinal & 1-lavatory. <br /> Room/Area wall(s) Floor Ceiling Base trim Class Index Height Color Remarks1 2 restroom. <br /> 0 each side (moisture-proof sheetrock in Women: 1-toilet& 1-lavatory. <br /> O O <br /> Retail/Halls Semi-gloss paint Extg 16"x16"ceramic tExtg T-bar w/2'x4' Floor to he Min.5"vinyl base Class C TBD O <br /> panels ceiling Provided Fixtures: Unisex restroom w/ 1-toilet, 1-urinal & Q °° <br /> Extg T-bar w/2'x4' Floor toStora a Rm Semi-gloss paint Ext 16"x16"ceramic the panels Min.5vinyl base Class C ceiling TBD W O <br /> 1-lay. per CPC 422.2(2). No drinking fountain per CPC 415.2. H N <br /> Extg T-bar w/2'x4' Floor to *Nominal Q 0 <br /> Q Office Semi-gloss paint Extg 16"x16"ceramic tile panels Min.5"vinyl base Class C ceiling TBD Z O �- <br /> 4'High FRP panels;semi- Sheetrock w/Semi- Floor to N a <br /> Q Unisex Restroom gloss paint panels&walls Extg 16"x16"ceramic the gloss paint Min.5"vinyl base Class C ceiling white FRP wall panels floor to 4'high. New Doors Schedule 'Substitute shall be equivalent or better Q <br /> © Extg T-bar 2'x4' Floor to <br /> Secure Storage Semi-gloss paint Extg 16"x16"ceramic tile Min.5"vinyl base Class C TBD No. Qt r �j <br /> panels ceiling y Type ManuPr. Model# Door type *Material Width Hgt. Thick Frame Core Handing Finish Insulate Label' Closer Anchor Lock Type Safety G/az Operation Window/Lite Remarks <br /> w w <br /> 16 ga Latch w/ Provide ADA handle outside&panic bar Accessibility: PLANS INDEX <br /> Q <br /> Q 1❑ " 80" 1.75" Steel Poly LH Prime No 3hr/PP/S Yes SS No No <br /> Steel Panic bar inside Sheet No. Plan Title <br /> 0 Project was determined in � <br /> 1 Interior Masonite 07139 Flush Hardwood 36" 80" 1.75" Solid LH Prime No No SS Deadbolt No No Provide ADA handle outside 1 Demo/ Remodel Floor Plans <br /> 0 compliance with accessible 2 Electrical Plan <br /> path of travel features per 3 Plumbing /Accessibility Plans <br /> 0 <br /> Inside view 2016 CBC Section 11 B-202.4. 4 Construction Detail <br /> ❑1 ❑2 4❑ — 5 Roof Equip /Site Plans <br /> All exterior doors to be weather-stripped and have thresholds. 6 Title 24 <br /> Abbreviations:Poly=Polystyrene;Hony=Honeycomb;RH=Right hand;LH=Left hand;CR=Standard arm closer;PR=Parallel arm closer;WS=Wood stud anchor;SS=Steel stud anchor;MA=Masonry wall anchor;Anod Alum=Anodized Aluminum;3hr-Fire rated,PP=Positive pressure,S=Smoke. <br />