Laserfiche WebLink
t <br /> SAN MOWN Environmental Health Department <br /> c� L)U 11N I Y -_ <br /> Package Sewage Treatment Plant Inspection Report <br /> Facility Name: Facility Address: Date: <br /> TAHAMA VILLAGE MOBILE HOME PARK 10780 N HWY 99 , STOCKTON June 30, 2022 <br /> Observations and Corrective Actions <br /> Item# Remarks <br /> 5 OWTS 7.12 Monthly monitoring/ADF not completed. <br /> Provide monthly records for ADF and peak flow. <br /> OWTS 7.12 Regular monitoring by a certified sewage plant operator is required. Analysis required may include <br /> Biochemical Oxygen Demands, Dissolved Oxygen and settable solids of plant influents and effluents and at such <br /> other points on stream as may be necessary. Average daily flows and peak flows after plant is in operation are to be <br /> determined by a reliable method. Copies of these analyses and operational records shall be furnished to the <br /> Director of Environmental Health and the Central Valley Regional Water Quality Control Board. <br /> 6 OWTS 7.3 Insufficient or inadequate mechanical or electrical equipment. <br /> Pump for the polishing pond sprinkler aeration system is in not functioning. Note: the pump is in process of being <br /> repaired by Moormans water system. <br /> OWTS 7.3 Mechanical and electrical equipment shall be of such durable hardware,workmanship and installation <br /> as to insure against operational failure with normal maintenance. <br /> 9 OWTS 7.7 Public nuisance/safety or health hazard/system poorly maintained. <br /> Observed pipe seal at grinder tank leak sewage when pump turns on. Repair/replace seal. <br /> OWTS 7.7 The installation and operation of alternative treatment or engineered systems shall not create a public <br /> nuisance in regard to odor nor cause a potential or immediate safety or health hazard to the public. The discharge of <br /> effluent shall not cause contamination of the water bearing strata or surface watercourses. <br /> Overall Inspection Comments <br /> COMMENTS <br /> Notes: <br /> -Gate locked <br /> -Slight odors at plant permimeter, moderate odors near pond and treatment system inside the plant at this time. <br /> -Clarifier water is slightly murky, some suspended solids noted in the pond. <br /> -Casey Wichert is the Certified Waste water treatment operator for the plant. <br /> -Grinder influent pump is fully functioning a turns on intermittently via float system. <br /> -Aeration pumps for the treatment system were observed functioning at the time of inspection. However, they were recently <br /> repaired but are still not fully functioning per the operator and is scheduled for further repairs by next week. Contact the EHD <br /> when the repairs are completed. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Date: Inspector: Inspector Phone: <br /> Printed Name and Title: FRANK GIRARD[, Senior REHS (209)616-3044 <br /> FA0001136 PR0420088 SCO01 06/30/2022 <br /> EHD 42-06 Rev.04/07/2022 Page 2 of 2 Package Sewage Treatment Plant OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 952051 T 209 468-34201 F 209 464-0138 1 www.sjgov.org/EHD <br />