Laserfiche WebLink
WASTE DISCHARGE REQUIREMENTS ORDER NO. R5-2014-0006 -12- <br />FORWARD INC. AND REPUBLIC SERVICES INC. <br />FORWARD CLASS II LANDFILL <br />SAN JOAQUIN COUNTY <br /> <br /> <br />45. In 2007, the Discharger submitted a detailed re-evaluation of historic groundwater levels for <br />the area east of WMU FU-06. The report demonstrated that proposed LCRS base grades in <br />the area east of WMU FU-06 are at least five feet above the historic high groundwater level. <br />46. Monitoring data indicate background groundwater quality for first encountered groundwater <br />has electrical conductivity (EC) ranging between 900 and 1100 micromhos/cm, with total <br />dissolved solids (TDS) ranging between 600 and 800 milligrams per liter (mg/L). <br />47. The direction of groundwater flow is generally toward the north-northeast. The estimated <br />average groundwater gradient is approximately 0.002 feet per foot. The estimated average <br />groundwater velocity is 195 feet per year. <br />48. The designated beneficial uses of the groundwater, as specified in the Basin Plan, are <br />domestic and municipal water supply, agricultural supply, industrial service supply, and <br />industrial process supply. <br />GROUNDWATER AND UNSATURATED ZONE MONITORING <br />49. The existing groundwater monitoring network consists of two units, the Forward Unit with a <br />detection program and the Austin Road Unit with a detection program, a corrective action <br />program and an ongoing evaluation program. The groundwater monitoring network is <br />summarized in the following: <br />Unit Status Wells <br />Forward Background MW -22, MW -23R, MW -24 <br /> Detection MW -1A, -2A, -3A, -10, -13A, -14A, -15, -16, - <br />17, -18, -19, &-21 <br /> Domestic DW -9690 <br /> <br />Austin Road <br />Shallow Zone <br /> <br />Background <br /> <br />AMW -2 <br /> Detection AMW -5R & -12 <br /> Corrective <br />Action <br />AMW -1, -4, -10, -11, -13, -14, -18, -19, -21S, <br />-22S, -24SR, -29S, -30-S, -31S & -32S <br /> <br />Austin Road <br />Deep Zone <br /> <br /> Detection AMW -6 & -7 <br /> Corrective/ <br />Evaluation <br />AMW -13B, -18B, -19BR, -21, -22, -24R, -25, <br />-26R, -28, -29, -30, -31, & -32 <br /> Domestic 7898-A, 8106-A <br /> <br />50. Any additional groundwater wells installed as part of an investigation or for any other reason <br />shall be sampled quarterly for the parameters and constituents listed in Table I of the MRP <br />until they are either abandoned with concurrence of Water Board staff or they are