My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_JULY 2014 FINAL RCSI
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440011
>
Archieved Reports
>
ARCHIVED REPORTS_JULY 2014 FINAL RCSI
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/25/2024 11:36:58 AM
Creation date
12/16/2021 11:39:32 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
JULY 2014 FINAL RCSI
RECORD_ID
PR0440011
PE
4445
FACILITY_ID
FA0006918
FACILITY_NAME
FORWARD RESOURCE RECOVERY FACI
STREET_NUMBER
9999
Direction
S
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106003
CURRENT_STATUS
01
SITE_LOCATION
9999 S AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\cfield
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
353
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STANDARD PROVISIONS AND REPORTING REQUIREMENTS, JANUARY 2012 - 8 - <br />FOR WASTE DISCHARGE REQUIREMENTS <br />FOR DISCHARGES REGULATED BY SUBTITLE D AND/OR TITLE 27 <br /> <br /> <br />F. STANDARD CONSTRUCTION SPECIFICATIONS <br /> <br />1. The Discharger shall submit for review and approval at least 90 days prior to <br />proposed construction, design plans and specifications for new landfill modules <br />that include the following: <br />a. Detailed construction drawings showing all required liner system <br />components, the LCRS, leachate sump, unsaturated zone monitoring <br />system, any proposed landfill gas monitoring and extraction points, and <br />access to the LCRS for required annual testing. <br />b. A Construction Quality Assurance (CQA) Plan prepared by a <br />California-registered civil engineer or certified engineering geologist, and <br />that meets the requirements of Title 27, section 20324. <br />c. A geotechnical evaluation of the area soils, evaluating their use as the base <br />layer or reference to the location of this information in the ROWD/JTD [Title <br />27, § 21750(f)(4)]. <br />d. Information about the seismic design of the proposed new module (or <br />reference to the location of this information in the ROWD/JTD) in <br />accordance with Title 27, section 20370. <br />e. A revised water quality monitoring plan for groundwater detection <br />monitoring (or information showing the existing plan is adequate) in <br />accordance with Title 27, section 20415. <br />f. An Operation Plan (or reference to the location of this information in the <br />ROWD/JTD) meeting the requirements of Title 27, section 21760(b). <br />2. All containment structures shall be designed by, and construction shall be <br />supervised by, a California registered civil engineer or a certified engineering <br />geologist, and shall be certified by that individual as meeting the prescriptive <br />standards, or approved engineered alternative design, in accordance with this <br />Order prior to waste discharge. <br />3. The Discharger shall not proceed with construction until the construction plans, <br />specifications, and all applicable construction quality assurance plans have <br />been approved. Waste management units shall receive a final inspection and <br />approval of the construction by Central Valley Water Board staff before use of <br />the unit commences [Title 27, § 20310(e)]. <br />4. Any report, or any amendment or revision of a report, that proposes a design or <br />design change that might affect a waste management unit’s containment <br />features or monitoring systems shall be approved by a California registered civil <br />engineer or a certified engineering geologist [Title 27, § 21710(d)].
The URL can be used to link to this page
Your browser does not support the video tag.