My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_JULY 2014 FINAL RCSI
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440011
>
Archieved Reports
>
ARCHIVED REPORTS_JULY 2014 FINAL RCSI
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/25/2024 11:36:58 AM
Creation date
12/16/2021 11:39:32 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
JULY 2014 FINAL RCSI
RECORD_ID
PR0440011
PE
4445
FACILITY_ID
FA0006918
FACILITY_NAME
FORWARD RESOURCE RECOVERY FACI
STREET_NUMBER
9999
Direction
S
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106003
CURRENT_STATUS
01
SITE_LOCATION
9999 S AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\cfield
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
353
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STANDARD PROVISIONS AND REPORTING REQUIREMENTS, JANUARY 2012 - 18 - <br />FOR WASTE DISCHARGE REQUIREMENTS <br />FOR DISCHARGES REGULATED BY SUBTITLE D AND/OR TITLE 27 <br /> <br /> <br />15. If the laboratory suspects that, due to a change in matrix or other effects, the <br />true detection limit or quantitation limit for a particular analytical run differs <br />significantly from the laboratory-derived MDL/PQL values, the results shall be <br />flagged in the laboratory report accordingly, along with estimates of the <br />detection limit and quantitation limit actually achieved. The MDL shall always <br />be calculated such that it represents the lowest achievable concentration <br />associated with a 99% reliability of a nonzero result. The PQL shall always <br />be calculated such that it represents the lowest constituent concentration at <br />which a numerical value can be assigned with reasonable certainty that it <br />represents the constituent’s actual concentration in the sample. Normally, PQLs <br />should be set equal to the concentration of the lowest standard used to calibrate <br />the analytical procedure. <br /> <br />16. All QA/QC data shall be reported, along with the sample results to which they <br />apply, including the method, equipment, analytical detection and quantitation <br />limits, the percent recovery, an explanation for any recovery that falls outside <br />the QC limits, the results of equipment and method blanks, the results of spiked <br />and surrogate samples, the frequency of quality control analysis, and the name <br />and signature of a responsible person from the laboratory. Sample results <br />shall be reported unadjusted for blank results or spike recoveries. In <br />cases where contaminants are detected in QA/QC samples (i.e., field, trip, or lab <br />blanks), the accompanying sample results shall be appropriately flagged, but the <br />analytical results shall not be adjusted. <br /> <br />17. Unknown chromatographic peaks shall be reported, flagged, and tracked for <br />potential comparison to subsequent unknown peaks that may be observed in <br />future sampling events. Identification of unknown chromatographic peaks that <br />recur in subsequent sampling events may be required. <br /> <br />18. The sampling interval of each monitoring well shall be appropriately screened <br />and fitted with an appropriate filter pack to enable collection of representative <br />groundwater samples [Title 27, § 20415(b)(4)(B)]. Groundwater samples shall <br />not be field-filtered prior to laboratory analysis [40 C.F.R. § 258.53(b)]. <br />Groundwater samples needing filtering (e.g., samples to be analyzed for <br />dissolved metals) shall be filtered by the laboratory prior to analysis. <br /> <br />19. Groundwater elevations shall be measured in each well immediately prior to <br />purging, each time groundwater is sampled. The owner or operator shall <br />determine the rate and direction of groundwater flow each time groundwater is <br />sampled. Groundwater elevations in wells which monitor the same waste <br />management area shall be measured within a period of time short enough to <br />avoid temporal variations in groundwater flow which could preclude accurate <br />determination of groundwater flow rate and direction [40 C.F.R. § 258.53(d)]. <br /> <br />20. Monitoring wells, piezometers, and other measurement, sampling, and analytical <br />devices must be operated and maintained so that they perform to design
The URL can be used to link to this page
Your browser does not support the video tag.