My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
4770
>
3600 - Recreational Health Program
>
PR0546551
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2021 4:42:49 PM
Creation date
12/20/2021 1:49:00 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3600 - Recreational Health Program
File Section
WORK PLANS
RECORD_ID
PR0546551
PE
3611
FACILITY_ID
FA0026400
FACILITY_NAME
STONEBRIER APARTMENTS
STREET_NUMBER
4770
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95210
CURRENT_STATUS
01
SITE_LOCATION
4770 WEST LN
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SA NJ O A Q U I N Env, mental Health Department <br /> COUNTY— <br /> sloped not less than 1/4 inch (6.4mm) per foot to floor drains or other approved <br /> surface water disposal areas. Carpeting and other similar artificial floor covering <br /> shall not be permitted on shower and toilet room floors. <br /> 12.31168.4.3 A means to limit the hot water to 110°F (61°C) maximum shall be <br /> provided to prevent scalding. This temperature limit control shall not be <br /> adjustable by the bather. <br /> 13,One guarded jet drinking fountain shall be provided for the first 250 pool users <br /> and an additional fountain shall be provided for each additional 200 pool users <br /> unless water is available at adjacent living quarters, or in an adjacent building <br /> such as clubhouse or recreational facility. <br /> 14.Install a sump for backwashing the filtration system in the equipment room. The <br /> sump must be sized handle the filter size and volume of water to clean the filters. <br /> Provide calculations for the sump to this department. 3132B Cartridge filters <br /> required the following. 3132B.2 An approved wash down area equipped with <br /> potable water shall be provided in the pool equipment area with permanently <br /> installed drainage piping discharging to the public sewer or wasterwater system <br /> approved by the enforcing agency. <br /> 15.Showers and dressing facilities shall be provided for users of the pool. Showers <br /> and dressing facilities may not be required when pool users have access to such <br /> facilities in adjacent living quarters. Public toilet facilities may be omitted when <br /> pool users have access to toilet facilities either in living quarters located not more <br /> than 300 feet in travel distance from the pool or in an adjacent building such as a <br /> recreational facility, clubhouse or cabana. <br /> 16.Built-in vacuum suction lines are not allowed in the pool as shown on your plans. <br /> Re-submit all documentation addressing the conditions above to our department for review. <br /> Please contact Jeff Carruesco at 209-468-3438 or Vidal Pedraza at (209) 468-0334 to <br /> schedule the required inspections. <br /> Sincerely, <br /> ff Carruesco, R.E.H.S. <br /> Program Coordinator <br /> 3 of <br />
The URL can be used to link to this page
Your browser does not support the video tag.