Laserfiche WebLink
SAN$,J O A Q U I N Environmental Health Department <br /> COUNTY- <br /> 6. <br /> OUNTY6. Fencing shall be a minimum of 5 feet high. Openings, holes or gaps in the <br /> enclosure, doors and/or gates shall not allow the passage of a 4-inch diameter <br /> sphere. The enclosure shall be constructed over a hard and permanent material <br /> equivalent to concrete: and shall be designed and constructed so that it cannot be <br /> readily climbed by small children. Horizontal and diagonal member designs which <br /> might serve as a ladder for small children are prohibited. Horizontal members' shall <br /> be spaced at least 48 inches apart. No planter or other structures that can be <br /> climbed shall be permitted within 5 feet of the outside of the pool enclosure or <br /> within a 5 foot arc. <br /> 7. A flowmeter must be installed on a horizontal straight run of pipe with a minimum <br /> of 10 pipe diameters before and 4 pipe diameters after the flowmeter. It should be <br /> positioned after the filter and before the heater. I may be installed after the heater, <br /> if a great enough distance can be maintained so that heated water will not damage <br /> the flowmeter. <br /> 8. 3111 B.3 Stairs. Each step of a stair shall have a tread in accordance with Figure <br /> 31 B-7. Risers shall conform to Figure 31 B-7. At least one hand rail shall be <br /> provided extending from the deck to not less than a point above the top of the <br /> lowest step installed in accordance with Figure 31 B-7. The tread on the top step <br /> must be 14 inches to 18 inches. The top of the hand rail must be 28 inches to 36 <br /> inches from each step and the deck. <br /> 9. 3111 B.4 Ladder and Recessed Step Dimensions. Ladder treads and recessed <br /> steps shall have a minimum tread of 5 inches (127 mm) and a width of 14 inches <br /> (356 mm) and shall be designed to be readily cleaned. Step risers shall be <br /> uniform and shall not exceed 12 inches (305 mm) in height. The first riser shall be <br /> measured from the deck. <br /> 10.311213.3 The overhang for either bull-nosed coping or cantilevered decking shall <br /> not exceed 2 inches (51 mm) or be less than 1 inch (25 mm) and shall not <br /> exceed 2 '/z inches (64 mm) in thickness. <br /> 11.3116B.3.1 Floors. Floors shall have a hard, nonabsorbent surface, such as <br /> Portland cement concrete, ceramic tile or other approved material, which extends <br /> upwards onto the wall at least 5 inches (127 mm) with a coved base. Floors <br /> which may be walked on by a wet bather shall be slip resistant. Floors shall be <br /> sloped not less than 1/4 inch (6.4mm) per foot to floor drains or other approved <br /> surface water disposal areas. Carpeting and other similar artificial floor covering <br /> shall not be permitted on shower and toilet room floors. <br /> 12.3116B.4.3 A means to limit the hot water to 110°F (61'C) maximum shall be <br /> provided to prevent scalding. This temperature limit control shall not be <br /> adjustable by the bather. <br /> 13.One guarded jet drinking fountain shall be provided for the first 250 pool users <br /> and an additional fountain shall be provided for each additional 200 pool users <br /> 2 of3 <br />