Laserfiche WebLink
Environmental Health Department <br />Aboveground Petroleum Storage Act Inspection Report <br />Date: <br />December 28, 2021 <br /> Facility Address: <br /> 23987 N HWY 99 , ACAMPO <br /> Facility Name: <br /> LODI AIRPORT <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br /> 713 CFR 112.7(e), 112.8(c)(6) Failed to test or inspect each container for integrity based on industry standards. <br />OBSERVATION: Facility failed to test each aboveground container for integrity based on industry standards, as <br />discussed in the SPCC Plan. Section 4.2.6 of the SPCC Plan requires formal inspections of the 10,000 gallon Jet A <br />and 10,000 gallon AvGas tanks by May 1, 2019. Formal inspections have not been completed. <br />REGULATION GUIDANCE: REGULATION GUIDANCE: 112.8(c)(6) Test or inspect each aboveground container <br />for integrity on a regular schedule and whenever you make material repairs. You must determine, in accordance <br />with industry standards, the appropriate qualifications for personnel performing tests and inspections, the frequency <br />and type of testing and inspections, which take into account container size, configuration, and design (such as <br />containers that are: shop-built, field-erected, skid-mounted, elevated, equipped with a liner, double-walled, or <br />partially buried). Examples of these integrity tests include, but are not limited to: visual inspection, hydrostatic <br />testing, radiographic testing, ultrasonic testing, acoustic emissions testing, or other systems of non-destructive <br />testing. You must keep comparison records and you must also inspect the container's supports and foundations. In <br />addition, you must frequently inspect the outside of the container for signs of deterioration, discharges, or <br />accumulation of oil inside diked areas. Records of inspections and tests kept under usual and customary business <br />practices satisfy the recordkeeping requirements of this paragraph. <br />112.7(e) Inspections, tests, and records. Conduct inspections and tests required by this part in accordance with <br />written procedures that you or the certifying engineer develop for the facility. You must keep these written <br />procedures and a record of the inspections and tests, signed by the appropriate supervisor or inspector, with the <br />SPCC Plan for a period of three years. Records of inspections and tests kept under usual and customary business <br />practices will suffice for purposes of this paragraph. <br />CORRECTIVE ACTION: Immediately conduct the necessary integrity testing on the 10,000 gallon Jet A and 10,000 <br />gallon AvGas tanks based on industry standards. Submit a copy of the test results to the EHD. <br />This is a Class II violation. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, by 1/27/2022 <br />To minimize person to person contact EHD is choosing to write the name of person receiving the report instead <br />of having them sign. Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate <br />($152). To schedule an appointment, please call (209) 468-3420. <br />The following was observed during this inspection: <br />- 10,000 gallon Jet A tank <br />- 10,000 gallon AvGas tank <br />Reviewed: <br />- SPCC Plan <br />- Inspection records <br />FA0011210 PR0526951 SC001 12/28/2021 <br />EHD 28-01 Rev. 12/06/2021 Aboveground Petroleum Storage Act OIRPage 5 of 6 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD