My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
CORRESPONDENCE_2005-2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WAVERLY
>
6484
>
4400 - Solid Waste Program
>
PR0440004
>
CORRESPONDENCE_2005-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/17/2025 10:07:54 AM
Creation date
12/30/2021 9:47:56 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
CORRESPONDENCE
FileName_PostFix
2005-2006
RECORD_ID
PR0440004
PE
4433 - LANDFILL DISPOSAL SITE
FACILITY_ID
FA0004517
FACILITY_NAME
FOOTHILL LANDFILL
STREET_NUMBER
6484
Direction
N
STREET_NAME
WAVERLY
STREET_TYPE
RD
City
LINDEN
Zip
95236
APN
09344002
CURRENT_STATUS
Active, billable
SITE_LOCATION
6484 N WAVERLY RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\cfield
Supplemental fields
Site Address
6484 N WAVERLY RD LINDEN 95236
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
322
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4.5 Compliance with §60.759(c)(1) or (2) <br />§60.759(c) Each owner or operator seeking to comply with <br />§60.752(b)(2)(i)(A) shall convey the landfill gas to a control system in <br />compliance with §60.752(b)(2)(iii) through the collection header pipe(s). <br />The gas mover equipment shall be sized to handle the maximum gas <br />generation flow rate expected over the intended use period of the gas <br />moving equipment using the following procedures: <br />4.5.1 Landfill Gas Extraction Component Installation <br />§60.759(c)(2) For new collection systems, the maximum flow rate shall <br />be in accordance with §60.755(a)(1). <br />§60.752(b)(2)(i)(B) The collection and control system design plan shall <br />include any alternatives to the operational standards, test methods, <br />procedures, compliance measures monitoring-, record keeping or <br />reporting provisions of sw 753 throng i r S proposed l y the owner <br />or operator. <br />The initial GCCS flare station and blowers will be designed for 2000 SUM, sufficient to <br />handle all anticipated landfill gas at least through year 2017. The flare station will be <br />expanded in the future to provide sufficient vacuum on the wells and burn all collected <br />gas. <br />4.6 Compliance with §60.753(d) <br />§60.753(d) Operate the collection system so that the methane <br />concentration is less than 500 parts per million above background of the <br />surface of the landfill. ...A surface Emissions Testing Protocol shall be <br />developed that includes a topographical map with the monitoring route... <br />Areas with steep slopes or other dangerous areas may be excluded from <br />surface testing. <br />As required by §60.753(4), San Joaquin County will monitor the surface of the landfill. If <br />the GCCS at the Foothill Landfill does not maintain surface emissions below the HSPS <br />requirement, the GCCS will be adjusted or modified in accordance with HSPS <br />requirements and as described in ` (Surface Emissions Response Plan). <br />4.7 Alternatives and Compliance with §60.752(b)(2) <br />§60.752(b)(2) If the calculated NMOC emission rate is equal to or <br />greater than 50 mega grams per year, the owner or operator shall: <br />Foothill Sanitary Landfill 15 Public Works/Solid Waste <br />LFG CS Design Plan County of San Joaquin - March 10, 2005 <br />