Laserfiche WebLink
2`P°, " '" 2 SAN J OAQ U I N Environmental Health Department <br /> oLL�� ca <br /> f � COUNTY Jasjit Kang , REHS , Director <br /> orMuniappa Naidu , REHS , Assistant Director <br /> girFoa�' Greatness grows here . <br /> PROGRAM COORDINATORS <br /> Robert McClellon , REHS <br /> Jeff Carruesco , REHS , RDI <br /> Willy Ng , REHS <br /> Steven Shih , REHS <br /> Michelle Henry, REHS <br /> September 9 , 2022 Elena Manzo , REHS <br /> Janelle Dockham <br /> Nwestco , LLC <br /> 2209 Zeus Court <br /> Bakersfield , CA 93308 <br /> Re : YRC Inc SR0085660 <br /> 1535 E Pescadero Ave , Tracy , CA95304 <br /> The San Joaquin County Environmental Health Department ( EHD) has completed the review of the <br /> application for a permit to do the following on the underground storage tank ( UST) system at the above <br /> noted address : <br /> • Remove penetrations in waste oil tank (tank 6) sump <br /> • Install new penetrations in waste oil tank (tank 6) sump <br /> The permit has been approved with the following conditions : <br /> 1 . Contact the local fire department , the San Joaquin Valley Air Pollution Control District , and the <br /> San Joaquin County Community Development Department for any applicable permits and <br /> requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work . All new addenda supersede the previous ones . <br /> 3 . Provide written notification to ustCc sigov . org to arrange the following appointments ( a 48- hour <br /> notice is required for inspection appointments) . <br /> a . 24- hour hydrostatic test (or equivalent) on waste oil tank (tank 6) piping sump . <br /> b . Primary piping soap test and one hour pneumatic pressure test at 110 % of operating <br /> pressure , or 40 psi , whichever is greater on the waste oil tank (tank 6) primary pipe that <br /> was disconnected to newly installed penetration . <br /> c . If concrete will be broken near the waste oil tank (tank 6) , a secondary containment test <br /> must be performed on the waste oil tank (tank 6) once concrete is poured in accordance <br /> with the manufacturer' s guidelines . <br /> 4 . Any individual performing the work of a service technician must meet the following <br /> qualifications : <br /> a . Possess or be employed by a person who possesses one of several permissible valid , <br /> current contractor' s licenses issued by the Contractors State License Board ( may be <br /> issued to the installation company) , or a Tank Tester' s license issued to the individual by <br /> the State Water Board <br /> b . Possess or work under the direct and personal supervision of an individual physically <br /> present at the work site who possesses a valid , current California UST Service Technician <br /> certificate issued by the International Code Council ( ICC ) <br /> c . Possesses a valid , current certificate of training from the manufacturer(s ) of the <br /> component (s) being tested , repaired , or serviced <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468-3420 F 209 464 -0138 1 www . sjgov . org /ehd <br />