My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6633
>
2300 - Underground Storage Tank Program
>
PR0231784
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/30/2022 7:58:18 AM
Creation date
1/6/2022 8:43:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0231784
PE
2361
FACILITY_ID
FA0003834
FACILITY_NAME
H & S ENERGY PRODUCTS LLC #3081
STREET_NUMBER
6633
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
097-410-48
CURRENT_STATUS
01
SITE_LOCATION
6633 PACIFIC AVE
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br /> Designated IST Operator Visual Inspection Report <br /> 8. UST SYSTEM INSPECTION <br /> j List below and in Section 3 all containment sumps that have had a release detection alarm <br /> since the previous Designated UST Operator Inspection Report and have not been responded <br /> to by a qualified service technician. Containment sumps listed below require a visual <br /> inspection for damage, water, debris, hazardous substance, and proper sensor location. <br /> i Is the containment sump free of damage, water, debris and hazardous substances? <br /> Containment Sump iD Yes No Containment Sump ID Yes INo i <br /> 17 E <br /> Are all sensors in visually inspected containment sumps located to detect a release at <br /> i the earliest opportunity? <br /> (-Is the spill containment free of damage, water. debris, and hazardous substances? Is the fill pipe <br /> free of obstructions? Is fill cap securely on the fill pipe? <br /> Spill Containment ID -µrvYes No Spill Containment ID_.__.____ -Yes No <br /> �J <br /> ❑ <br /> i <br /> El 1:1 El <br /> Is the UDC free of damage, water, debris. and hazardous substances and all sensors located to <br /> defect a release at the earliest opportunity? E] No UDC(s) at this facility <br /> UDC ID Yes No UDC ID Yes No� <br /> ,----- ! ---- <br /> l MT <br /> r <br /> _I^ r r] ® I r l <br /> rl Mechanical float mechanisms used in UDCs. <br /> All answers marked "No' must be described by the designated UST operator in Section 3. <br /> Page 3 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.