Laserfiche WebLink
...... . .... .. . <br /> OUTPUT RELAY SETUP L 5:FUEL ALARM <br /> - - - - - - - - - - - - L 6:FUEL ALARM EVR.-ISP SETUP <br /> L10:FUEL ALARM <br /> R 1 :REG 2 �� L11 :FUEL ALARM <br /> TYPE: L12:FUEL ALARM <br /> PUMP CONTROL OUTPUT L13:FUEL ALARM EVR TYPE: BALANCE <br /> TANK #: 3 L14:FUEL ALARM , <br /> L15:FUEL ALARM BALANCE NOZZLE TYPE <br /> - NO ALARM ASSIGNMENTS '- L 2:SENSOR OUT ALARM VST <br /> L 3:SENSOR OUT ALARM <br /> L 5:SENSOR OUT ALARM VAPOR PROCESSOR TYPE <br /> R 4:REMOTE ALARM L 6:SENSOR OUT ALARM NONE <br /> TYPE: L 7:SENSOR OUT ALARM <br /> MOMENTARY L 8:SENSOR OUT ALARM <br /> NORMALLY OPEN L 9:SENSOR OUT ALARM ANALYSIS TIMES <br /> L10:SENSOR OUT ALARM TIME: 9:59 AM <br /> Nit ALARM ASS I GNNtEfVTS - L 1 1 :SENSOR OUT ALARM DELAY MINUTES: 1 <br /> — L12:SENSOR OUT ALARM <br /> PLLp LINE DISABLE SETUPL13:SENSOR OUT ALARM <br /> - - - - - - - _ L14:SENSOR OUT ALARM ACCEPT HIGH ORVR: <br /> Q 1 :SUF'kEME L15:SENSOR OUT ALARM ENABLED <br /> L 2:SHORT ALARM <br /> L 3:SHORT ALARM ISD HOSE TABLE <br /> IN-TANK ALARMS L 5:SHORT ALARM ID FP FL HL AA RR <br /> T 1 :HIGH WATER ALARM L 6:SHORT ALARM ----------------- <br /> T 1 :LOW PRODUCT ALARM L10:SHORT ALARM U1 01 O1 02 01 00 <br /> L11 :SHORT ALARM 02 02 02 02 01 00 <br /> LIQUID SENSOR ALMS L12:SHORT ALARM 03 03 03 02 02 00 <br /> L 1 :FUEL ALARM L13:SHORT ALARM 04 04 04 02 -02 00 <br /> L 4:FUEL ALARM L14:SHORT ALARM 05 05 05 02 .03 00 <br /> L10:FUEL ALARM 06 06 06 02 03 00 <br /> L11 :FUEL ALARM L15:SHORT ALARM 07 07 07 02 04 00 <br /> L12:FUEL ALARM L 2:HIGH LIQUID ALARM 08 08 08 02 04 00 <br /> L13:FUEL ALARM L 3:HIGH LIQUID ALARM 09 09 09 02 05 00 <br /> L14:FUEL ALARM L 2:LIQUID WARNING 10 16 10 02 05 00 <br /> L15:FUEL ALARM L 3:LIQUID WARNING 11 17 11 02 06 00 <br /> L 1 :SENSOR OUT ALARM 12 18 12 02 06 00 <br /> L 4:SENSOR OUT ALARM ISD SITE ALARMS <br /> L 7:SENSOR OUT ALARM ISD GROSS PRES FAIL <br /> L 'B:SENSOR OUT ALARM ISD DEGRD PRES FAIL ISD AIRFLOW METER MAP <br /> L 9:SENSOR OUT ALARM ISD VAPOR LEAK FAIL ID SERIAL NUM LABEL <br /> L10:SENSOR OUT ALARM ------------------------ <br /> L11 :SENSOR OUT ALARM ISD HOSE ALARMS 1 72040 DISP 1 <br /> L12:SENSOR OUT ALARM ALL:FLOW COLLECT FAIL 2 72019 DISP 3-4 <br /> L13:SENSOR OUT ALARMr1Hx1���vti0x �tlu� 3 72070 DISP 5-6 <br /> L14:SENSOR OUT ALARM - - - _ - - - - - - - - 4 72048 DISP 7-8 <br /> L15:SENSOR OUT ALARM 5 72021 DISP 9-10 <br /> L 1 :SHORT ALARM s I :DIISP 1-2 6 72303 DISP 11-12 <br /> L 4:SHORT ALARM CATEGORY AIR FLOW METER <br /> LIO:SHORT ALARM <br /> L11 :SHORT ALARM s ':DISP 3-4 ISD FUEL GRADE HOSE MAP <br /> L12:SHORT ALARM CATEGORY AIR FL061 METER 1 2 3 4 <br /> L13:SHORT ALARM FP MHH MHH MHH MHH AA <br /> L14:SHORT ALARM s 3:DISP 5-6 ------- - <br /> L15:SHORT ALARM CATEGORY AIR FLOW METER 01 201 901 101 U U 1 <br /> L 1 :HIGH LIQUID ALARM 02 202 902 102 U U 1 <br /> L 1 :LIQUID WARNING s 4:DISP 7-8 03 203 903 103 U U 2 <br /> CATEGORY AIR- FLOW METER 04 204 904 104 U U 2 <br /> ISD SITE ALARMS 05 205 905 105 U U 3 <br /> ISD GROSS PRES FAIL s 5:DISP 9-10 06 206 906 106 U U 3 <br /> ISD DEGRD PRES FAIL CATEGORY AIR FLOW METER 07 207 907 107 U U 4 <br /> 08 208 908 108 U U 4 <br /> ISD VAPOR LEAK FAIL s 6:DISP 11-12 09 209 909 109 U U 5 <br /> CATEGORY AIR FLOW METER 16 210 910 110 U U 5 <br /> ISD HOSE ALARMS 17 211 911 111 U U 6 <br /> ALL:FLOW COLLECT FAIL s 7:PRES SENSR DISP 7-8 18 212 912 112 U U 6 <br /> CATEGORY VAPOR PRESSURE <br /> Q 2:REGULAR LABEL TABLE <br /> IN-TANK, ALARMS ------------'--'-------- <br /> T 2:HIGH WATER ALARM 1 : UNASSIGNED <br /> T 3:HIGH WATER ALARM 2: BLENDS <br /> 3: REGULAR <br /> LIQUID SENSOR ALMS 4: MID GRADE <br /> L 2:FUEL ALARM 5: PREMIUM <br /> L 3:FUEL ALARM 6: GOLD <br /> 7: BRONZE <br /> 8: SILVER <br /> 9: BLEND2 <br /> 10: BLEND4 <br />