Laserfiche WebLink
t <br /> oc.4lttfY• c <br /> •y SAN JOAQUIN COUNTY <br /> " ► : ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue , Stockton , CA 95205 -6232 <br /> go <br /> 0 994 `P (209 ) 468-3420 Fax: (209) 468-3433 Web : www . sigov. org/ehd <br /> UNDERGROUND STORAGE TANK PROGRAM <br /> NOTICE OF SIGNIFICANT VIOLATION <br /> Imminent Threat — Red Tagged No Imminent Threat <br /> Possible Red Tag Within 7 Days <br /> Facility Grant Line Shell * Date: 6/21 /2022 <br /> Name : <br /> Facility 2375 W Grant Line Rd city : Tracy zip code : 95376 <br /> Address <br /> owner or RADC ENTERPRISES INC Telephone : 909 -394 -4728 <br /> O erator: <br /> Tank: 87A Tank: 87B Tank : 91 <br /> Tanks Red Tagged : Product Product Product <br /> Level : Level : Level : <br /> Red Tag Red Tag Red Tag <br /> ID # : ID #: ID #: <br /> Type of significant violation . <br /> ❑x A violation that is causing , or threatens to cause a liquid release of petroleum from an underground storage tank <br /> system , including , but not limited to : the failure of any required overfill prevention system , where the failure is <br /> causing or threatens to cause a release ; or the failure of a required spill containment structure , where the failure is <br /> causing or threatens to cause a release to the environment due to a spill or an overfill . <br /> 0 A violation that impairs the ability of an underground storage tank system to detect a liquid leak or contain a liquid <br /> release of petroleum in the manner required by law. <br /> px A chronic violation or a violation that is committed by a recalcitrant violator. In determining whether a violation is <br /> chronic or a violator is recalcitrant , the local agency shall consider whether there is evidence indicating that the <br /> violator has engaged in a pattern of neglect or disregard with respect to any requirement in Title 23 ( not including <br /> corrective action) . <br /> On 5/26/2021 and 5/26/2022 Carol Presto of the San Joaquin County Environmental Health Department (EHD) performed a routine undergroun <br /> storage tank inspections at the above reference site . The site was found to be out of compliance . The outstanding violations include but are not limite <br /> to the following : <br /> - On the 5/30/2019 and 5/18/2020 inspection reports , the facility was cited for not having approved overfill on all tanks . An Overfill Prevention Equipmen <br /> Inspection Report Form was submitted to EHD on 5/ 12/2020 for testing conducted on 5/2/2019 but 48-hour notification was not provided for the test <br /> work orders for the test and a copy of the results were not on site during the 5/18/2020 inspection . The overfill equipment listed on the result was OP <br /> 61 SO but flappers were not observed during the 5/18/2020 and 5/26/2021 inspections . New Franklin Fueling Defender drop tubes were installed unde <br /> permit number SR0083186 but by a technician not certified by the manufacturer. The installed drop tubes failed initial testing on 10/6/2021 and have ye <br /> to be re-tested showing passing results . <br /> - On 5/26/2022 the diesel leak detector failed to detect a leak when tested . On all Designated Operator reports observed , starting 11 /8/2021 , a W1 <br /> WPLLD communication alarm has been noted as in alarm but has not yet been addressed . The alarm history observed during the inspection shows th <br /> initial W1 WPLLD communication alarm on 10/22/2021 . <br /> - During the 5/26/2022 inspection , dispensers 1 /2 , 11 /12 , 13/14 , 15/16 , 17/18 , 19/20 , and 21 /22 were observed with piping located outside of the unde <br /> dispenser containment (UDC) that would not allow leaks to flow back into the UDCs . The piping located outside of UDCs were initially observed <br /> CONTINUED ON PAGE 2 <br /> FAILURE TO IMMEDIATELY COMPLY WITH THIS NOTICE MAY RESULT IN ADDITIONAL VIOLATIONS <br /> Inspected By : , Print Name : Carol Presto <br /> / Signature of Registered E vironmental Health Specialist / <br /> Received By : IV f(1 �-� y P Date : ZI [ <br /> Signatu of Owner/Operator <br /> REV 04/19/12 PAGE 1 OF 2 NOTICE OF SIGNIFICANT VIOLATION <br />