inorganic constituent exceeds its concentration limit in one or both verification samples, <br /> an evaluation monitoring plan will be proposed. <br /> 4.3 Monitoring Points <br /> 4.3.1 Groundwater <br /> The groundwater well network for both units consists of up gradient well MW-4 and <br /> down gradient wells MW-2R, MW-3, MW-5 and MW-6. Well MW-IA, which had <br /> previously been considered up gradient, was found to be cross gradient from the landfill, <br /> and not down gradient of any portion of the landfill. <br /> LF-1's corrective action monitoring points consist of the following: <br /> • Up gradient well MW-4 <br /> • Down gradient wells MW-3, MW-5, and MW-6 <br /> • Cross gradient well MW-lA <br /> LF-2's detection monitoring points consist of the following: <br /> • Up gradient well MW-4 <br /> • Down gradient wells MW-2R, MW-5 and MW-6 <br /> 4.3.2 Surface Water <br /> Surface water sampling points are SW-1 and SW-2 for both LF-1 and LF-2. SW-1 is the <br /> upstream sampling point. <br /> 4.3.3 Vadose Zone <br /> The vadose zone monitoring network consists of lysimeters LZ-1, LZ-2, LZ-3, LZ-4, LZ- <br /> 5, and pan lysimeters under LF-2. LZ-1 is the background vadose zone lysimeter. A <br /> vadose zone gas monitoring network also consists of 25 tri-level perimeter soil gas <br /> probes SG-12 and SG-102 through SG-125. <br /> In addition, LF-1 is monitored with soil gas probes SG-1, SG-2A, SG-3A, SG-4, SG-5, <br /> SG-6A, SG-7, SG-9, SG-10A, and SG-11A situated around the perimeter of LF-1. The <br /> locations designated with an "A" are tri-level monitoring probes. <br /> Foothill WQPS Rev Ldoc <br /> 4-6 <br />