My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
2575
>
2300 - Underground Storage Tank Program
>
PR0231070
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2022 8:09:01 AM
Creation date
1/7/2022 3:06:58 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0231070
PE
2351
FACILITY_ID
FA0006439
FACILITY_NAME
COUNTRY CLUB MOBIL CIRCLE K
STREET_NUMBER
2575
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
2575 COUNTRY CLUB BLVD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
该页面上没有批注。
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following is an itemized list of underground storage tank violations that have not <br /> been addressed for COUNTRY CLUB MOBIL CIRCLE K as of April 19 , 2022 . <br /> Open violations from January 28 , 2022 inspection <br /> Violation #313 - Monitoring system incapable of detecting entry into secondary containment (post-Jul <br /> 2004) . <br /> OBSERVATION : Vacuum sensors , S1 87 Product and S3 91 Product , were in alarm at the time of inspection . <br /> According to the owner, Sartaj ( Nick) Singh , Elite IV is waiting on parts to repair the sensors . <br /> REGULATION GUIDANCE : The continuous monitoring system shall be maintained to detect the entry of the liquid <br /> or vapor phase of the hazardous substance stored in the primary containment into the secondary containment, and <br /> to detect water intrusion into the secondary containment. <br /> CORRECTIVE ACTION : Correct immediately by having a properly licensed , trained , and certified contractor replace <br /> the failed component with a functional component (LG 113-x listed , if applicable ) , and obtain a permit within one <br /> business day from the EHD , if needed . If the failed component can't be replaced immediately, there is a possibility <br /> that the 87 and 91 UST systems may be red tagged to prevent fuel inputs . <br /> ❑ This violation was corrected ❑ This violation will be corrected by (date) : <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation : <br /> Violation #315 - Failure to maintain interstitial space to detect leaks before release to environment (post-Jul <br /> 2004) . <br /> OBSERVATION : Vacuum sensors , S1 87 Product and S3 91 Product, were in alarm at the time of inspection . <br /> According to the owner, Sartaj ( Nick) Singh , Elite IV is waiting on parts to repair the sensors . <br /> REGULATION GUIDANCE : The interstitial space of the UST shall be maintained , as designed , under constant <br /> vacuum or pressure such that a breach in the primary or secondary containment is detected before the hazardous <br /> substance is released into the environment. <br /> CORRECTIVE ACTION : Correct immediately by having a properly licensed , trained , and certified contractor replace <br /> the failed component with a functional component ( LG 113-x listed , if applicable ) , and obtain a permit within one <br /> business day from the EHD , if needed . If the failed component can't be replaced immediately, there is a possibility <br /> that the 87 and 91 UST systems may be red tagged to prevent fuel inputs . <br /> ❑ This violation was corrected ❑ This violation will be corrected by (date) . <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation : <br /> Page 2 of 2 <br />