15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 <br /> PLUMENG NOTE " <br /> NOTE: REFER TO FSEC LAYOUT/SCHEDULE FOR SPECIFIC EQUIPMENT TO BE SUPPLIED ON THIS P E U M H H G P 0 U G H H PLAN <br /> A PROJECT.THESE NOTES APPLY GENERICALLY TO ALL PROJECTS AND INCLUDE INFORMATION, A <br /> SUCH AS EXHAUST SYSTEMS AND WALK-IN COOLER,WHICH MAY NOT BE SUPPLIED ON THIS SCALE: 1 /4" = 099 <br /> PROJECT. <br /> I ALL ROUGH-IN CONNECTIONS SHOWN ON THE PLUMBING SHEET PERTAIN ONLY <br /> TO THE EQUIPMENT BEING SUPPLIED BY THE FSEC. MISC. FAUCETS, SHUT OFF <br /> VALVES, MIXING VALVES, PRESSURE REGULATORS, GREASE TRAPS, WATER <br /> HEATER, PRESSURE REDUCING VALVES, TAIL PIECES AND INDIRECT/DIRECT <br /> WASTE AND VENT LINES ARE INCLUDED IN THE SCOPE OF WORK UNLESS <br /> OTHERWISE NOTED ON PLAN OR PURCHASING CONTRACT. <br /> 2. OWNER/VENDOR SUPPLIED EQUIPMENT MUST BE CONFIRMED WITH OWNER PRIOR architects <br /> TO STARTING WORK. <br /> 3. PLUMBING CONTRACTOR (PC) SHALL BE RESPONSIBLE FOR ALL ROUGH-IN, TO TO <br /> INTERCONNECTIONS AND FINAL CONNECTIONS TO THE FOOD SERVICE EQUIPMENT +16" ROOF ROOF TIMOTHY P. HUFF & <br /> B AND OTHER SYSTEMS AS NOTED ON THE ARCH./ENG. PLANS. 5„ 5„ 17.2 17.5 5„ B ASSOCIATES <br /> 4, SHUT OFF VALVES SHALL BE ACCESSIBLE. , INC. <br /> 5. BACK-FLOW PREVENTION DEVICE SHALL BE SUPPLIED AT ALL FAUCETS WHERE 11'-5" 8" 3'-0" 12" 18" 6'-8" 6'-5" 5'-7" 2'-7" 0'-1" Timothy P. Huff,AIA Architect <br /> A THREADED SPOUT IS PROVIDED. 519 McHenry Ave., Modesto, CA 95354 <br /> 6. MANUFACTURER'S SHEETS SHALL BE REVIEWED AND VERIFIED TO THE PLAN. -,o Ph: (209)571-2232 Fax: (209)571-1936 <br /> ANY DISCREPANCIES SHALL BE BROUGHT TO DESIGNERS ATTENTION PRIOR TO <br /> BEGINNING WORK. 1 1 i 11 <br /> 7. SODA SYSTEM CONDUIT CHASE, IF NEEDED, SHALL INCORPORATE LONG L------- <br /> 1------- <br /> J D ARCh'� <br /> DIAMETER SWEEPS AT 90° JOINTS AND CONSIST OF MATERIALS MEETING CODE C LED IL <br /> I Qi Y PAiQ <br /> COMPLIANCE FOR METHOD AND LOCATION OF INSTALLATION. 3 Ji Ji gO�N < tiG �� <br /> 8. HOT WATER PIPING SHALL BE INSULATED. 171- A <br /> 9. DRAIN LINES FROM ICE BINS, ICE SINKS, REMOTE REFRIGERATORS, FREEZERS, UV. 4 IIoNo. C <br /> AND WALK-IN REFRIG/FREEZERS SHALL BE INSULATED AND RUN TO NEAREST174 I <br /> C FLOOR SINK. DRAIN LINES AT RISK OF FREEZING ARE TO BE WRAPPED WITH L� = _� H C N 15527 Q <br /> HEAT TAPE BY E.C. ro C LED �� \ IL- ��� REN. 5/21 <br /> 10. SOFTENED WATER SHALL BE SUPPLIED TO DISH MACHINES, GLASS WASHERS, I 0 F <br /> STEAMERS AND ICE MACHINES. SOFTEN TO A MIN. OF 17-51 PPM (0-3 CP&\ <br /> GRAINS PER GALLON) VERIFY WITH ARCHITECT/OWNER. \ I 7 7.1 <br /> 11. GREASE TRAP/INTERCEPTOR WILL BE SIZED BY MECH. ENGINEER, LOCATED BY - - - - - ( i <br /> 11 <br /> E) <br /> Copyright 2021 -Timothy P. Huff&Associates <br /> ARCHITECT, AND SUPPLIED BY PC. 0 <br /> 12. WATER HEATER WILL BE SIZED BY MECH. ENGINEER, LOCATED BY ARCHITECT FS 6 <br /> AND PROVIDED BY PC. THE CAPACITY, BTU RATING AND RISE OF WATER 4'-2" 4'-7" 3'-4" 13'-10" + 2 I <br /> TEMPERATURE WILL BE PROVIDED TO THE HEALTH PLAN CHECKER. L -+48" IF--- z <br /> " <br /> 13. FLOOR SINK INSTALLATION MUST BE VERIFIED WITH LOCAL PLAN CHECK FOR 2'-211" 3'-11" 3'-0" 3'-7" ,J Qa <br /> HEIGHT (FLUSH WITH FINISH FLOOR OR 1" ABOVE FF). LOCATED AS TO BE 15" (E) <br /> EASILY ACCESSIBLE FOR CLEANING. 7.1 (E) u I 0 o <br /> D <br /> 4. EXHAUST SYSTEM MAKEUP AIR UNIT WILL BE PROVIDED WITH WATER AND DRAIN 7 9 1 FS 6 D O o <br /> LINE (IF ON ROOF DRAIN LINE GOES TO RAIN GUTTER), UNLESS NOTED =i 5" 9.4 D.4 9.3 0a LU <br /> OTHERWISE. QQ 2'-8" 3'-10" 14" 12" 2'-2" - Z 06 <br /> 15. PENETRATIONS AND PIPES SHALL BE FITTED WITH ESCUTCHEON COVERS, RINGS, _ _ �� Q _Ln ° Lon In Cdrn <br /> ETC. ALL GAPS, HOLES AND SEAMS WILL BE SEALED AND CAULKED PROPERLY " m m 9TYP. m <br /> PER HEALTH CODE REQUIREMENTS. J 12 121 +16 ®� +� + + 51 + p U <br /> 16. MOBILE COOKING EQUIPMENT WILL BE PROVIDED WITH QUICK DISCONNECT HOSES 49.1 38 « 1 52 C:, Z Q a <br /> (AGA APPROVED) BY FSEC AND INSTALLED BY PC. 12.1 12 49 2 +16" +'16" 2 5'-1" 16" O O w w <br /> 17. GAS SHUT OFF VALVE WILL BE PROVIDED BY FIRE SUPPRESSION SYSTEM +16" (E) o , 38.1 _ w J g <br /> INSTALLER, LOCATION TO BE VERIFIED FOR EASE OF RESETTING, INSTALLED BY L_ cn LL a <br /> v �/� + W =Q <br /> 18. GAS LINES MUST BE BLED OR AIR AND PILOT LIGHTS LIGHTED PRIOR TO FIRE 2 L +44" FS �/ W 0 N <br /> SUPPRESSION TEST AND AFTER. 1 0 N N N N ® o N g O N <br /> E 19. SYSTEM DRAWINGS OF DIAGRAMS, IF REQUIRED, WILL BE PROVIDED BY PC. IF 1 +44" o + + + + + � E I cA <br /> NONE EXIST AT TIME OF BID, CONFIRM IN WRITING WITH G.C. 18" <br /> 20, WHEN A LOW TEMPERATURE DISH MACHINE WITHOUT A BOOSTER HEATER IS O "' 2�6 34 2'=�" -1 --3--g- 4'-1" Q <br /> SPECIFIED, A DEDICATED HOT WATER LINE CARRYING 167` WATER TO THE DISH N ❑ I 1 <br /> MACHINE IS REQUIRED. ADDITIONALLY, ALL HAND SINKS MUST HAVE A MIXING <br /> VALVE. MIXING VALVE TO BE SUPPLIED BY THE P.C. N 3 3 4 5 6 <br /> 21. HAND SINKS TO HAVE TEMPERED WATER AT 110LO <br /> 22. IF A FLOOR SINK IS ELEVATED (NOT FLUSH W/FLOOR) IT MUST HAVE AN <br /> APPROVED INTEGRAL, CONTINUOUS COVED BASE WITH AT LEAST 8" RADIUS 1 <br /> COVING AT THE FLOOR/FLOOR SINK JUNCTURE AND THE FLOOR SURFACE <br /> SHALL EXTEND UP THE SIDES OF THE FLOOR SINK UP TO 4" (DEPENDING ON <br /> HOW HIGH THE FLOOR SINK IS ELEVATED). <br /> E81 <br /> F 23. CONDENSATE DRAIN LINES FROM COOLER/FREEZER BOXES TO HAVE P-TRAP IN 43 O o❑ ❑ ❑ F <br /> DRAIN LINE BEFORE AIR GAP. <br /> 24, WHEN POT SINKS, PRE-RINSE SINKS OR DISH WASHERS ARE REQUIRED TO - - <br /> HAVE A DIRECT WASTE CONNECTION BY LOCAL BUILDING DEPARTMENT, P.C. TO Consultants <br /> ENSURE THAT A FLOOR SINK, THROUGH OR DRAIN IS LOCATED DOWN STREAM. <br /> 11'-5" 3'-2" 6'-2" 3'-3" 3'-0" <br /> 7„ FS 5» g» <br /> 6 <br /> G G N <br /> W W <br /> PLUMBING LEGEND ~ W <br /> Z Q <br /> ROOF9 Q 99 2) GAS CONNECTION W Z <br /> 11 3 10 <br /> GAS CONNECTION WITH QUICK DISCONNECT � W <br /> 0. <br /> HOT & COLD WATER W/DIRECT DRAIN <br /> J <br /> NOTE: MAINTAIN MINIMUM Q �p HOT & COLD WATER SUPPLY 00 <br /> H [M­AE-UP10'-0" SEPARATION of EXHAUST1 H O Q <br /> LAIR O <br /> �_] <br /> EXHAUST BLOWER AND FAN HOT - COLD WATER SUPPLY n <br /> MAKE UP AIR UNIT Q ■ L� <br /> -- FILTERED WATER FROM OTHER LOCATIONW ` O <br /> ROOF ROOF ~ <br /> WASTE (DIRECT CONNECTED) W co <br /> 17.2 17.5 27 0 W ZLo <br /> DRAIN (INDIRECT CONN. TO FS BY OTHERS) � <br /> Q <br /> ® � � U Q <br /> 5/8" GYP. WALL W/ S/S T FLOOR DRAIN (FD) W <br /> UWALL LINER, TYP. QREMOTEQ QREMOTEQ T� � FLOOR SINK WITH HALF GRATE > <br /> GAS REGULATOR - IF COND. COND. \ \ W O Lu <br /> REQUIRED. �COOLERQ FRZR Q ( GREASE E OVERY 1 ® ® FLOOR DRAIN TROUGH WITH GRATING I Q Q <br /> OQ [ HOSE BIBB (HB) z <br /> GAS LOCK OR SHIN OFF Q Q GT GREASE TRAP (FLUSH WITH FLOOR) U Q LLI <br /> F19EXHAUST DUCT CONNECTION LU Q <br /> GAS PIPE SIZED PER I- � Z <br /> MANUF'R SPECIFICATIONS AIR SUPPLY DUCT CONNECTION Q <br /> FLEXIBLE GAS LINE TO Q REFRIGERATION ROUGH-IN CONNECTION 2 <br /> EQUIP., SIZED PER MFG. REMOTE E Q U P M E H T <br /> SPECIFICATION. ALLOW PLUMBING PROJECT NOTES � LU <br /> CONDENSER WATER SUPPLY & RETURN U Q <br /> ENOUGH SLACK LINE TO TRADES TO CONFIRM UTILITY REQUIREMENTS FOR ALL <br /> NOTE: IF A FLOOR SINK IS ELEVATED (NOT Q OWNER/VENDOR/EXISTING EQUIPMENT PRIOR TO ROUGH-IN. SCALL: 1 /4" - V-0" 0 SLEEVE FOR REFRIGERATION/SODA LINES <br /> J PULL EQUIP• 24" MIN, FLUSH W/FLOOR) IT MUST HAVE AN APPROVED J U N O <br /> i FROM WALL, TYP, INTEGRAL, CONTINUOUS COVED BASE WITH AT CODE REQUIRES THAT WHEN THE FIRE SUPPRESSION SYSTEM IS <br /> LEAST $" RADIUS COVING AT THE FLOOR/FLOOR DRAIN PIPE, SIZE VARIES Q ACTIVATED, ALL EQUIPMENT BELOW HOOD SHUT-OFF, INCLUDING <br /> 70/1RESTRAINING CABLE SINK JUNCTURE AND THE FLOOR SURFACE ALL GAS AND ELECTRIC APPLIANCES AND THE MAKE-UP AIR No. Description Date <br /> SHALL EXTEND UP THE SIDES OF THE FLOORSYSTEM. THE EXHAUST FAN MUST CONTINUE RUNNING. GAS <br /> p SINK UP TO 4" (DEPENDING ON HOW HIGH THE 1" AIR GAP, TYPICAL VALVE 2" OR SMALLER PROVIDED WITH THE FIRE SUPPRESSION <br /> FLOOR SINK IS ELEVATED). SYSTEM. E.C. TO WIRE OUTLETS TO MICRO SWITCHES AT <br /> LI FLOOR SINK FLUSH SUPPRESSION SYSTEM TANK CONTROLS OR PROVIDE SHUNT <br /> QQ SWITCHES. <br /> W/FLOORTYPICAL GAS C O N N E C TI O N Com, 1 899 NSURE SOME JURISDICTIONS Q S ALED.G.C. TOE ROOF ENETRATIONSALLTIONS TO BEO APPROVED BO <br /> ARE <br /> U REQUIRE TOP OF SINK 1" BUILDING OWNER FOR WARRANTY ISSUES. <br /> L EQUIPMENT RESTRAINT D E TA - AFF. VERIFY WITH LOCAL <br /> GRATE AUTHORITIES <br /> O E.C. TO WIRE FREEZER EVAPORATOR FAN DRAIN LINE, DOOR <br /> � Q HEATER & RUN CONTROL WIRES FOR ELECTRIC DEFROST TIMER. <br /> N K N.T.S. P.C. TO WRAP FREEZER COMPARTMENT EVAPORATOR FAN DRAIN K <br /> WITH HEAT TAPE. <br /> UDIMENSIONS FOR ABOVE GROUND ROUGH-IN'S FOR ELECTRICAL <br /> GAS CONNECTION FOR CASTORED EQUIPMENT, TYP. T & PLUMBING ARE TAKEN FROM CENTER OF KNOWN FEATURES <br /> TILE FLOOR SUCH AS EXISTING COLUMNS OR FROM INSIDE OF FINISHED <br /> WATER PROOF CENTERLINE OFUEXTERIORUWALLSM F CONSTRUCTION ON WALLS S <br /> WALLS, U.N.O. NDERGROND DIENSIONS MAY BE TAKEN FROM <br /> ITEM # QTY. DESCRIPTION MEMBRANE CEMENT BED NOT EXPECTED TO BE COMPLETED AT THE TIME OF FLOOR SINK <br /> Oa O O ROUGH-IN. TRADES ARE RESPONSIBLE FOR NOTIFYING FSEC OF Project Number 2008 <br /> 3 EXISTING CONVECTION OVEN, GAS DOME DISCREPANCIES IN DIMENSIONS AS SOON AS THEY ARE <br /> STRAINER DISCOVERED. Date 03.01.2021 <br /> U 4 1 EXISTING 6-BURNER RANGE W OVEN <br /> FS CD INDICATES LOCATIONS FOR FLOOR SINKS. FS (E) Drawn by M. Gray / M. Brown <br /> CD 5 EXISTING 36 GRIDDLE W OVEN Q INDICATES EXISTING FLOOR SINKS TO REMAIN AND BE RE-USED . <br /> ANY NEW FLOOR SINKS ARE PROVIDED & INSTALLED BY THE P.C. Checked by M. Gray / M. Brown <br /> O <br /> D STRUCTURAL SLAB PER LOCAL CODE REQUIREMENTS. P.C. TO VERIFY WHETHER L <br /> N 6 EXISTING 2499 COUNTERTOP GRIDDLE, W STAND FLOOR SINKS ARE TO BE INSTALLED FLUSH, RAISED 1" OR <br /> RAISED. <br /> FS 0 T <br /> U <br /> J DOREQUIRES SYPHON <br /> OREAKER. P.C. TOTYP . FLOOR O DETAIL QR <br /> (j Plot Date &Time 03/01/2021 8:00:00 PM <br /> Z:\1 Design Projects\Independents\' Manteca Senior-Center\1 -Redesign\MantecaSC=FS.dwg, 3/1 /2021 12:27:31 PM, QAutoC D PDF (General Documentation).pc3 r <br />