Laserfiche WebLink
Cn <br /> w <br /> ELECTRICAL SYMBOL LEGEND SHEET INDEX <br /> O <br /> z PANEL.- 'B' ENCLOSURE: NEMA 1 OPTIONS: HINGED COVER LIGHTING FIXTURE SCHEDULE 60.01 ELECTRICAL SYMBOLS, NOTES & DETAILS <br /> p VOLTAGE: 208Y1120V 3PH 4W MOUNTING: SURFACE MAIN: 100 AMP MLO TAG MANUFACTURER DESCRIPTION , LAMPS I WATTS :COLOR MOUNTING 1. EVERY SYMBOL SHOWN ON LEGEND MAY NOT APPEAR ON DRAWINGS. <br /> Z A LITHONIA ILED 1X4 TROFFER, INDIRECT, LED 27 WH RECESSED IN T-BAR OR FRAMED 2. DASHED ELECTRICAL EQUIPMENT GENERALLY INDICATES EXISTING EQUIPMENT. E1.01 ELECTRICAL SITE PLAN <br /> w LOAD VA BKR CIR CIR BKR VA LOAD #AVL425L-GZ10-LP835 PERFORATED METAL BASKET BYMFR GYPSUM BOARD CEILING 3. LONG-SHORT-SHORT-LONG DASHING GENERALLY INDICATES MATCH LINE OR DEFINES <br /> 0 AREA FOR SPECIAL NOTE. 62.00 ELECTRICAL DEMO PLAN <br /> ILLIJ SPARE 2011 1 2 2011 10$2 LIGHTS B LITHONIA LED 2x2 TROFFER, INDIRECT, j LED 31 WH RECESSED IN T-BAR CEILING 62.01 POWER FLOOR PLAN ARCHITECT PBK-WLC,Inc. <br /> X SPARE 20/1 3 4 2011 987 LIGHTS #2AVL2-30LHE-MDR-GZI0-LP835 PERFORATED METAL BASKET BYMFR E2.02 LIGHTING PLAN PBK-WLC.com <br /> W I I CIRCUIT RELATED: SACRAMENTO <br /> p x 63.01 ELECTRICAL ROOF PLAN <br /> Z SPARE 2011 5 6 ZOf1 $79 LIGHTS C FLUXWERKS LED RECESSED ❑OWNLIGHT LED 12 I WH RECESSED INT-BAR GELING 2520 Venture Oaks Way,Suite 440 <br /> #TCI-R-05-G-K1-MW-M1-835- .ANNULAR LIGHT RING,WHITE FINISH BYMFR = Sacramento,CA 95833 <br /> SPARE 2011 7 8 2011 -- SPARE B F2 MLIGHTING OR POWER CIRCUIT(S). ARROW INDICATES HOME RUN,LONGER TICK(S) 916-682-9494 P <br /> wD FLl1XWERKS LED PENDANT CYLINDER WITH LED 12 WH 36"CORD PENDANT BELOW INDICATE NEUTRAL WIRE(S),SHORTER STRAIGHT TICK(S)INDICATE PHASE WIRE(S), <br /> w SPARE - 20/1 9 10 2011 SPARE SLANTED SHORTER TICK(S)INDICATE SWITCH LEG(S),DOT(S) INDICATE GROUNDING <br /> 2 #TCI-P-05-G-03-W-W-M- ANNULAR LIGHT RING,WHITE FNISIH 8Y MFR T-BAR CEILING CONDUCTOR(S),DASHED WIRING(LONG-SHORT-LONG DASHES)INDICATES Electrical Engineering <br /> SPARE — 20/1 11 12 2011 -- SPARE 2 8 35 B-F2 WIRING BELOW SLAB OR GRADE,DASHED WIRING(SERIES OF SHORT DASHES) <br /> J E FLUXWERKS J .LED ADJUSTABLE ACCENT LIGHT, LED 12 WH SURFACE BELOW T-BAR CEILING INDICATES EXISTING WIRING,SLASH THROUGH ARROW INDICATES PARTIAL CIRCUIT, <br /> Q KVA FOR PHASE A 1.1 9 AMPERES #TCI-T-05-S-J1-W-M1- ANNULAR LIGHT RING,WHITE FNISH BY MFR "D"ON HOMERUN ARROW INDICATES DEDICATED CIRCUIT: PROVIDE A SEPARATE 6LEAF <br /> U <br /> KVA FOR PHASE B 1.0 8 AMPERES 8-35-B-F2UV1 NEUTRAL FOR EACH PHASE CONDUCTOR FOR ENTIRE LENGTH OF CIRCUIT FROM ENGINEERS <br /> F TBA IDECORATWE PENDANT INLED 20 PENDANT MOUNT? PANEL TO OUTLET; COUNT EACH NEUTRAL AS CURRENT-CARRYING AND GROUP A AP�(COMPANY <br /> U KVA FOR PHASE C 0-9 7 AMPERES` CONFERENCE ROOM TO BE BYMFR MAXIMUM OF SIX THHN/THWN CONDUCTORS IN A SINGLE RACEWAY; GROUNDING 2520 Venture Oaks Way,Suite 440.Sacramento,CA 95833 <br /> ILL! <br /> J SELECTED BYARCHETECT CONDUCTOR IS NOT COUNTED. <br /> p 916-682-9494 www. engineers.com <br /> job#:p2102201AR <br /> W ITOTAL KVA 2-9 G LITHONIA LED 1X4 TROFFER, INDIRECT, LED 27 WH RECESSED IN GYPSUM BOARD <br /> o #AVL425L-GZI O-LP835 WITH PERFORATED METAL BASKET FOR 6Y MFR OR ACOUSTIC TILE~ T� TELEPHONE CONDUIT SYSTEM. DASHED WIRING(LONG-SHORT-LONG DASHES) <br /> #DGA14 DRYWALL CEILING ADAPTER FLANGED RECESSED MOUNTING _ CEILING -------- INDICATES WIRING IN OR BELOW SLAB OR GRADE,DASHED WIRING(SERIES OF COMPONENT ANCH0RAGE NOTE <br /> w X LITHON[A u COMBINATION EXIT SIGN WITH u LED yy 1 u WH u SURFACE CLG OR WALL SHORT DASHES)INDICATES EXISTING WIRING. <br /> #EXRG EL M6 EMERGENCY LANTERN BY MFR Q JUNCTION BOX. "J"MAY BE OMITTED IF BOX IS WITHIN OR ATTACHED TO FLUORESCENT <br /> `GREEN ON WHITE LIGHT FIXTURE SYMBOL ON PLANS. ALL MECHANICAL,PLUMBING AND ELECTRICAL COMPONENTS SHALL BE ANCHORED AND <br /> INSTALLED PER THE DETAILS ON THE DSA APPROVED CONSTRUCTION DOCUMENTS. THE <br /> POINT OF BRANCH CIRCUIT TAP FOR SEPARATELY SWITCHED FIXTURE GROUP. FOLLOWING COMPONENTS SHALL BE ANCHORED OR BRACED TO MEET THE FORCE AND <br /> REFERENCE CATEGORY"B"LIGHTING SYMBOLS FOR FURTHER INFORMATION. DISPLACEMENT REQUIREMENTS PRESCRIBED IN THE 2019 CBC,SECTIONS 1617A.1.18 THROUGH <br /> 1617A.1.26 AND ASCE 7-16 CHAPTER 13,26 AND 30: <br /> GROUNDING ELECTRODE. 1. ALL PERMANENT EQUIPMENT AND COMPONENTS. <br /> 2. TEMPORARY,MOVABLE OR MOBILE EQUIPMENT THAT IS PERMANENTLY ATTACHED <br /> PANEL: 'C' ENCLOSURE: NEMA 3R OPTIONS: PANEL: 'A' ENCLOSURE: NEMA 1 OPTIONS: HINGED COVERLIGHTING: (e.g.HARD WIRED)TO THE BUILDING UTILITY SERVICES SUCH AS ELECTRIC,GAS OR <br /> WATER. "PERMANENTLY ATTACHED"SHALL INCLUDE ALL ELECTRICAL CONNECTIONS <br /> VOLTAGE: 208Y/1 20V 3PH 4W MOUNTING: UNISTRUT FRAME MAIN: 225 AMP MLO VOLTAGE: 208Y1120V 3PH 4VV MOUNTING: SURFACE MAIN: 400 AMP MLO EXCEPT PLUGS FOR 110/220 VOLT RECEPTACLES HAVING A FLEXIBLE CABLE. <br /> LOAD VA BKR CIR CIR BKR VA LOAD LOAD VA BKR CIR CIR BKR VA LOAD D LED LIGHTING FIXTURE. LETTER INDICATES TYPE,SMALL LETTER INDICATES SWITCH 3. TEMPORARY,MOVABLE OR MOBILE EQUIPMENT WHICH IS HEAVIER THAN 400 POUNDS <br /> CONTROL,NUMBER INDICATES CIRCUIT,CROSS HATCHING INDICATES FIXTURE ON OR HAS A CENTER OF MASS LOCATED 4 FEET OR MORE ABOVE THE ADJACENT FLOOR <br /> (E)AIR COND 'AC-1' (ROOF) 2665 30/3 1 2 30/3 2665 (E) AIR GOND 'AC-4' (ROOF) RECEPS 1000 2011 1 2 1 2011 800 RECEPS EMERGENCY SYSTEM,FOR SOLID CIRCLE WITHIN FIXTURE REFERENCE APPROPRIATE OR ROOF LEVEL THAT DIRECTLY SUPPORT THE COMPONENT IS REQUIRED TO BE <br /> CATEGORY"A"CIRCUIT RELATED SYMBOL. RESTRAINED IN A MANNER APPROVED BY DSA. <br /> 2555 3 1 4 2555 !, 11 ,I RECEPS 1200 2011 3 4 2011 800 RECEPS <br /> H STRIP TYPE LED LIGHTING FIXTURE,LETTER INDICATES TYPE,SMALL LETTER THE FOLLOWING MECHANICAL AND ELECTRICAL COMPONENTS SHALL BE POSITIVELY ATTACHED <br /> 2665 " 5 1 6 " 2665 " " RECEPS 1200 20/1 5 6 20/1 800 RECEPS INDICATES FIXTURE SWITCH CONTROL,NUMBER INDICATES CIRCUIT,FOR SOLID TO THE STRUCTURE BUT NEED NOT DEMONSTRATE DESIGN COMPLIANCE WITH THE <br /> CIRCLE ATTACHED TO FIXTURE REFERENCE APPROPRIATE CATEGORY"A"CIRCUIT REFERENCES NOTED ABOVE. THESE COMPONENTS SHALL HAVE FLEXIBLE CONNECTIONS <br /> (E)AIR COND 'AC-2' (ROOF) 2665 30/3 7 8 3013 1 2655 (E) AIR COND 'AC-5' (ROOF) RECEPS 1000 20/1 7 8 20/1 1000 RECEPS RELATED SYMBOL. PROVIDED BETWEEN THE COMPONENT AND ASSOCIATED DUCTWORK,PIPING,AND CONDUIT. <br /> FLEXIBLE CONNECTIONS MUST ALLOW MOVEMENT IN BOTH TRANSVERSE AND LONGITUDINAL <br /> 2565 9 10 11 2655 RECEPS 1000 2011 9 10 2011 1000 RECEPS 0 LED LIGHTING FIXTURE. LETTER INDICATES TYPE,SMALL LETTER INDICATES SWITCH DIRECTIONS: <br /> CONTROL,NUMBER INDICATES CIRCUIT,FOR SOLID CIRCLE REFERENCE APPROPRIATE <br /> " 2665 " 11 12 " 2665 " " II RECEPS 1000 2011 11 12 2011 1000 RECEPS CATEGORY"A"CIRCUIT RELATED SYMBOL. 1. COMPONENTS WEIGHING LESS THAN 400 POUNDS AND HAVE A CENTER OF MASS <br /> (E)AIR COND 'AC-3 (ROOF) 2665 30/3 13 14 3013 �- SPARE SPARE -- 2011 13 14 20/1 1000 RECEPS 6 DESIGNATES FIXTURE ON EMERGENCY POWER.RE:LIGHTING PLAN NOTES AND LOCATED 4 <br /> DIRECTLY FEET OR LESS ABOVE THE <br /> THE COMPONENT. <br /> � ADJACENT FLOOR OR ROOF LEVEL THAT <br /> f i FIXTURE SCHEDULE NOTES FOR ADDITIONAL INFORMATION. 2. COMPONENTS WEIGHING LESS THAN 20 POUNDS,OR IN THE CASE OF DISTRIBUTED <br /> 2665 15 16 -- SPARE SPARE -- 2011 15 16 2011 1000 RECEPS SYSTEMS,LESS THAN 5 POUND PER FOOT,WHICH ARE SUSPENDED FROM A ROOF OR z <br /> It <br /> It <br /> 2665 It <br /> 17 18 " -- SPARE SPARE -- 2011 17 18 2011 600 RECEPS HO WALL OR BRACKET MOUNTED FIXTURE OR DEVICE. FLOOR OR HUNG FROM A WALL. <br /> SPACE ONLY — 19 20 2011 RECEPS--ROOF SPARE -- 2011 19 20 1000 OVENlel EXIT LIGHT FIXTURE. LETTER INDICATES TYPE,NUMBER INDICATES CIRCUIT,NUMBER THE ANCHORAGE OF ALL MECHANICAL,ELECTRICAL AND PLUMBING COMPONENTS SHALL BE 0 <br /> 1 f AND LOCATION OF SHADED TRIANGLE SECTIONS INDICATES NUMBER OF EXIT SIGN SUBJECT TO THE APPROVAL OF THE DESIGN PROFESSIONAL IN GENERAL RESPONSIBLE LL_ <br /> SPACE ONLY — -- 21 22 2011 -- SPARE SPARE -- 2011 21 22 1000 FACES AND DIRECTION OF EACH FACE.PROVIDE CHEVRON DIRECTIONAL INDICATORS CHARGE OR STRUCTURAL ENGINEER DELEGATED RESPONSIBILITY AND ACCEPTANCE BY DSA. J <br /> SPACE ONLY — -- 23 24 20/1 -- SPARE -- -- AS SHOWN ON DRAWINGS. THE PROJECT ANCHORED IN ACCORDANCE EILL WITH AIFY THAT ALL BOVE REQUIREMENTS. <br /> AND EQUIPMENT HAVE BEEN <br /> SPARE 2011 23 24 20/1 SPARE V <br /> CONTROL: <br /> SPACE ONLY - -- 25 26 -- -- SPACE ONLY SPARE -- 2011 25 26 2011 -- SPARE <br /> SPACE ONLY - 27 28 -- SPACE ONLY $ SWITCH. SMALL LETTER INDICATES FIXTURES CONTROLLED,"P"INDICATES PILOT LIGHT, ELECTRICAL D I S T R I B U T I 0 N z <br /> �� SPARE I -- 2011 27 2$ 2011 -- SPARE "WP"INDICATES WEATHERPROOF,"K"INDICATES KEY OPERATED,"MO"INDICATES SPOT n/ <br /> SPACE ONLY — -- 29 30 -- -- SPACE ONLY MOMENTARY CONTACT,"2"INDICATES DPDT,"3"INDICATES 3-WAY,"4"INDICATES 4-WAY, LL <br /> SPARE -- 2011 29 30 2x11 -- SPARE "M"INDICATES MANUAL MOTOR STARTER,CIRCUIT DESIGNATION NEXT TO SWITCH LU <br /> KVA FOR PHASE A 13.3 111 AMPERES SPACE ONLY -- -- 31 32 -- -- SPACE ONLY INDICATES BRANCH CIRCUIT NUMBER. SYSTEM BRACING NOTE _ <br /> B WALL BOX DIMMER SWITCH. "MARK"INDICATES WATTAGE IF OTHER THAN 600,"3D" <br /> KVA FOR PHASE B 13-3 111 AMPERES SPACE ONLY -- -- 33 34 -- -- SPACE ONLY $ INDICATES 3-WAY DIMMER. LL <br /> PIPING,DUCTWORK,AND ELECTRICAL DISTRIBUTION SYSTEMS SHALL BE BRACED TO COMPLY <br /> KVA FOR PHASE C 13.3 111 AMPERES SPACE ONLY -- -- 35 36 -- -- SPACE ONLY $$ MULTI-LEVEL SWITCH.CIRCUIT DESIGNATION NEXT TO SWITCH INDICATES BRANCH WITH THE FORCES AND DISPLACEMENTS PRESCRIBED IN ASCE 7-16 SECTION 13.3 AS DEFINED IN CN 0 <br /> CIRCUIT NUMBER. ASCE 7-16 SECTION 13.6.5, 13.6.6, 13.6.7,13.6.8;AND 2019 CBC,SECTION 1617A.1.24,1617A.1.25,AND W z <br /> TOTAL KVA 40.0 SUBFEED PANEL 'C' 13325 22513* 37 3$ 100/3 1082 SUBFEED PANEL 'S' $T DIGITAL TIME SWITCH 1617A.1.26. <br /> 41 !1 If II 11 fl it II <br /> 13325 39 40 987 ® PHOTOELECTRIC CONTROL. THE METHOD OF SHOWING BRACING AND ATTACHMENTS TO THE STRUCTURE FOR THE IDENTIFIED Q J <br /> 11 It 11 11 II tl 11 It ? DISTRIBUTION SYSTEM ARE AS NOTED BELOW. WHEN BRACING AND ATTACHMENTS ARE BASED <br /> 13325 41 42 879 EMERGENCY POWER OFF(EPO)PUSHBUTTON. ON A PRE-APPROVED INSTALLATION GUIDE(E.G.,OSHPD OPM FOR 2013 CBC OR LATER),COPIES = 0 <br /> KVA FOR PHASE A20.2 16$ AMPERES O PUSH BUTTON. OF THE BRACING SYSTEM INSTALLATION GUIDE OR MANUAL SHALL BE AVAILABLE ON THE JOBSITE O <br /> PRIOR TO START OF AND DURING THE HANGING AND BRACING OF DISTRIBUTION SYSTEMS. THE <br /> KVA FOR PHASE B 20.3 169 AMPERES WALL MOUNT OCCUPANCY SENSOR.. STRUCTURAL ENGINEER OF RECORD SHALL VERIFY ADEQUACY OF THE STRUCTURE TO SUPPORT <br /> C) z U)THE HANGER AND BRACE LOADS. Z <br /> KVA FOR PHASE C 1$.$ 157 AMPERES DUAL TECHNOLOGY CEILING MOUNTED OCCUPANCY SENSOR. <br /> MECHANICAL PIPING(MP),MECHANICAL DUCTS(MD),PLUMBING PIPING(PP),ELECTRICAL O U) 0 <br /> TOTAL KVA 59.3 AOR CEILING MOUNTED RESTROOM OCCUPANCY SENSOR. DISTRIBUTION SYSTEMS(E): LU <br /> C CEILING MOUNTED CORRIDOR OCCUPANCY SENSOR. MP MD PP E OPTION 1: DETAILED ON THE APPROVED DRAWINGS WITH J C.0U <br /> [ } MOUNT AS SUBFEED BREAKER PROJECT SPECIFIC NOTES AND DETAILS. V G U = o O <br /> HB CEILING MOUNTED HIGH CEILING OCCUPANCY SENSOR. El El ❑ ® O O w 6' z <br /> MP MD PP E OPTION 2: SHALL COMPLY WITH THE APPLICABLE OSHPD I- Q U O <br /> PRE-APPROVAL(OPM-0295-13). (n U) <br /> WALL MOUNTED THERMOSTAT z U <br /> ❑ ❑ ❑ ❑ Q 0 <br /> 4 WALL MOUNTED CARBON DIOXIDE SENSOR p UO z <br /> ti cj OU <br /> POWER OUTLETS: <br /> 20A-125V DUPLEX RECEPTACLE."GF"INDICATES GROUND FAULT CIRCUIT INTERRUPTER <br /> 3-5"CO TO PGE RECEPTACLE. KI PP:Public Schools <br /> PADMOUNTED TRANSFORMER SERVICE:800 AMPERES 1 $6 20A-125V DUPLEX RECEPTACLE.OCCUPANCY CONTROLLED RECEPTACLE <br /> AT 120/208 VOLTS 3�4W J NORTHERN CALIFORNIA <br /> EST AIC=18 KA 36 20A-125V FOURPLEX RECEPTACLE. <br /> UNDERGROUND PULL AND <br /> 20A-125V FOURPLEX RECEPTACLE.OCCUPANCY CONTROLLED RECEPTACLE <br /> M METER SECTION <br /> SPECIAL PURPOSE SINGLE POWER RECEPTACLE. RATED AS INDICATED(IF NO RATING <br /> INDICATED,RECEPTACLE RATING SHALL MATCH BRANCH CIRCUIT OVERCURRENT <br /> MAIN&DISTRIBUTION SECTION PROTECTIVE DEVICE SIZE AND SHALL MEET REQUIREMENTS OF EQUIPMENT BEING <br /> CONNECTED),"C"INDICATES CLOCK OUTLET. <br /> 800/3 SERVICE <br /> MAIN BREAKER � 20A-125V FLUSH FLOOR DUPLEX RECEPTACLE. 20A WHEN INDICATED OR IF BRANCH Al <br /> CIRCUIT SERVES ONLY SINGLE DUPLEX. PROVIDE CARPET FLANGE WHERE <br /> '� APPLICABLE. <br /> 20A-125V DUPLEX TAMPER RESISTANT RECEPTACLE WITH(2)USB CHARGING PORTS. <br /> CH <br /> NEUTRAL <br /> 800 A BUS SAME AS DUPLEX RECEPTACLE EXCEPT ISOLATED GROUND TYPE RECEPTACLE. Pl P2 P3 P4 P5 P6 <br /> • <br /> SAME AS FOURPLEX RECEPTACLE EXCEPT ISOLATED GROUND TYPE RECEPTACLE. <br /> AC INDICATES RECEPTACLE SHALL BE MOUNTED ABOVE COUNTER TOP.REFER TO N <br /> 400/3 100/2 100/2 100/2 100/2 100/2 100/2 100/2 BUSSED ARCHITECT FOR EXACT HEIGHT ABOVE COUNTER. <br /> A-B B-C A-C A-B B-C A-C A-B SPACE <br /> LC 1—X CIRCUIT DESIGNATION NEXT TO RECEPTACLE DEVICES INDICATES BRANCH CIRCUIT <br /> NUMBER.RE:PANEL SCHEDULES FOR INFORMATION. PLAN TRUE <br /> KEY PLAN NORTH NORTH <br /> WP "WP"INDICATES WEATHER PROOF DEVICE. <br /> #3/0 CU TELEPHONE/DATA: <br /> WALL TELEPHONE OUTLET. "P"INDICATES PAY TYPE,"W"INDICATES WALL MOUNTED <br /> PHONE. PROVIDE NEMA 5-15R OUTLET FOR EACH TTY,TDD OR OTHER SCREEN OR Q,�,OFESS/O/V <br /> CARD-ACCESS TELEPHONE. E <br /> BOND NON-ELECTRICAL <br /> METALLIC PIPING AND EXPOSED ® FLUSH FLOOR TELEPHONE OUTLET WITH CARPET FLANGE WHERE APPLICABLE. Co <br /> STRUCTURAL METAL TO THE GROUND 8 SURFACE FLOOR TELEPHONE OUTLET. "T"INDICATES TWO OUTLETS IN ONE BOX. 0. 113 2 cn <br /> ELECTRODE PER C.E.C.250.104 PROVIDE CARPET FLANGE WHERE APPLICABLE. * Exp.12-31-21 <br /> a TWO PORT WALL COMMUNICATIONS OR DATA OUTLET. REFER TO SERIES SHEETS <br /> FOR EXACT BOX/CONDUIT REQUIREMENTS. FC T R <br /> ® FLUSH FLOOR COMMUNICATIONS OR DATA OUTLET. REFER TOTS'SERIES SHEETS FOR 9�F OF CALF', <br /> EXACT BOX/CONDUIT REQUIREMENTS. PROVIDE CARPET FLANGE WHERE APPLICABLE. <br /> ® SURFACE FLOOR COMMUNICATIONS OR DATA OUTLET. REFER TOTS'SERIES SHEETS <br /> FOR EXACT BOX/CONDUIT REQUIREMENTS. PROVIDE CARPET FLANGE FLANGE WHERE <br /> v <br /> THREE%4'X 10' APPLICABLE. <br /> CLIENT <br /> (KIPP:PUBLIC SCHOOLS NORTHERN CALIFORNIA <br /> COPPERCLAD STEEL GROUND RODS EQUIPMENT: <br /> SPACE 6'APART,MINIMUM PROJECT NUMBER <br /> LU N +42" A NOTATION INDICATING THE MOUNTING HEIGHT OF A DEVICE AS MEASURED FROM P2102201 AR <br /> H FINISHED FLOOR OR GRADE TO CENTER LINE OF DEVICE. <br /> ,�� DATE: 07/01/2021 <br /> LU 4t 4t 4t 4t 4t 4t � / MOTOR. <br /> YC C C C C C C DRAWN BY: SL CHECKED BY: LWM <br /> CD <br /> i o v v v v v v v [:]J DISCONNECT SWITCH. FRAME SIZE/FUSE SIZE/POLES AS INDICATED, "NF"INDICATES <br /> NON-FUSIBLE. NEMA 1 ENCLOSURE UNLESS OTHERWISE NOTED. PROVIDE FUSED REVISIONS <br /> U BUSWAY PLUG WHEN SWITCH IS INDICATED ON BUSWAY.ALL DISCONNECT SWITCHES # DESCRIPTION DATE <br /> _� <br /> 0 SHALL BE 30/NF/3 UNLESS OTHERWISE NOTED. <br /> Q E] SINGLE CIRCUIT BREAKER IN INDIVIDUAL ENCLOSURE. <br /> U <br /> ® MAGNETIC MOTOR CONTROLLER. NUMBER INDICATES NEMA SIZE.STARTER NEMA SIZE <br /> m SHALL BE"NEMA 1"UNLESS OTHERWISE NOTED. <br /> co COMBINATION DISCONNECT SWITCH/MOTOR CONTROLLER. <br /> 00 <br /> i CONTACTOR <br /> p <br /> °>° CONSTRUCTION DOCUMENTS <br /> 0 <br /> 0 <br /> ELECTRICAL <br /> N <br /> 0 <br /> SHEET INDEX, <br /> N � <br /> N LO <br /> LEGEND & NOTES <br /> j a a ❑ P1 P2 P3 P4 P5 P6 P7 <br /> Uco <br /> V <br /> 0 o O RELOCATABLE BLDGS <br /> `�" ONE LINE DIAGRAM <br /> a N 1 <br /> N SCALE: NO SCALE <br />