Laserfiche WebLink
W <br /> ENERALN TE <br /> W <br /> W <br /> pwi <br /> 0 1. REFER TO G0.31 FOR SIGNAGE INFORMATION INCLUDING TYPE,SIZE AND INSTALLATION <br /> 0 HEIGHTS. <br /> 06 <br /> a <br /> ARCHITECT PBK-WLC,Inc. <br /> CODE ANALYSIS - BLDG "Al " SACRAMENTO PBK-WLC.com <br /> z 2520 Venture Oaks Way,Suite 440 <br /> Sacramento,CA 95833 <br /> 1. GOVERNING CODE: 2019 CALIFORNIA BUILDING CODE(CBC) 916-682-9494 P <br /> m <br /> 0 2. OCCUPANCYTYPE: A-3,B,S-1,E <br /> ry (CBC 302) <br /> 0 3. CONSTRUCTION TYPE: TYPE VB WITH AUTOMATIC FIRE SPRINKLER SYSTEM <br /> (CBC 602&TABLE 601) <br /> 4. BASIC ALLOWABLE HEIGHT& OCCUPANCY ALLOWABLE ALLOWABLE ALLOWABLE <br /> BUILDING AREA: GROUP BLDG AREA S1 #OF STORIES BLDG HEIGHT <br /> (CBC TABLES 504.3,504.4,506.2) GROUP A-3 24,000 SF 1 60'-0" <br /> GROUP B 38,000 SF 1 60'-0" <br /> GROUP S-1 9,000 SF 1 40'-0" <br /> �------------------------------------------ GROUP E 9,500 SF 1 40'-0" <br /> I I <br /> I I <br /> I I <br /> I I 5. ACTUAL BUILDING DATA: OCCUPANCY ACTUAL ACTUAL#OF ACTUAL BLDG <br /> I I GROUP BLDG AREA STORIES HEIGHT <br /> I I GROUP A-3 1,701 SF 1 18'-0" <br /> I I GROUP B 1,782 SF 1 18'-0" <br /> I I GROUP S-1 519 SF 1 18'-0" <br /> J L-------------- <br /> --------------------------------------------------------------------------------------------------------- -------------------------------------------------------------- <br /> r- T-------------- r---------------------------------, _r - GROUP E 848 SF 1 18'-0" <br /> I I I I <br /> I <br /> TOTAL: 4,850 SF <br /> I II I I I <br /> I I I I I I <br /> O i 0 i O i J� low 6. NONSEPARATED SPACES: MOST RESTRICTIVE:GROUP A-3 <br /> I I I IEL STORAGE (CBC 508.3) If=0.75 <br /> L------------------J L------------------J Aa=24,000+(8,000 x 0.75)=30,000 <br /> 4,850 SF<30,000 SF <br /> 1014.04 7 F <br /> 7. FIRE RESISTANCE STRUCTURAL FRAME: 0 HOURS <br /> S1 <br /> ^ REQUIREMENTS:771 BEARING WALLS-EXTERIOR: 0 HOURS <br /> 10 4.0 I (CBC TABLE 601) BEARING WALLS-INTERIOR: 0 HOURS <br /> I CONI E E C ROOM RN IP SO FIE I <br /> 58 3'-0 05 F B10 S 50 10 14.04 i - <br /> 2 >0 S1 I NON-BEARING WALLS& FIRE RATING BASED ON <br /> 0 - - - - - - i PARTITIONS-EXTERIOR: FIRE SEPARATION DISTANCE: <br /> 1014.04 ----'------ TI N I (CBC TABLE 602) X<5' 1 HOURS <br /> 48"x30" 10 1 14.(6 <br /> 5'5_X510' 1 HOURS Q <br /> S1 11 176 F S 1 i 10'<_X<30' 0 HOURS <br /> P N TE O FI E y R A E FIC I Z <br /> 1 1 _ 1° I 10!_X530 0 HOURS <br /> j1 0 ---- B 1510 14.04 I �� n/ <br /> 87 F 1 1 4 7 F 10'4.04- 101 0 S1 i ACTUAL SEPARATION DIST: 5520-0 0 HOURS <br /> 60"x60" S 1 S1 4 6o"x60" 1 i NON-BEARING WALLS& 0 HOURS <br /> ------------- - LL <br /> I o I <br /> I 48'x48"' ;48"x48" ��_ _ I PARTITIONS-INTERIOR: <br /> 1a 1 .E. i FLOOR CONSTRUCTION: 0 HOURS J <br /> 1 4. 4 <br /> I Q , -r _23'-0° �g I ROOF CONSTRUCTION: 0 HOURS <br /> 1 = W 0 1 ❑ <br /> 1 <br /> - M v I SHAFT ENCLOSURES: 0 HOURS <br /> 14.0 <br /> 1 431 1 - - - - <br /> 1 1 S1 4 1 4.)3 i (CBC 713) 7 <br /> I x I Z <br /> I I <br /> i/ ____________________ � PROJECTIONS: 0 HOURS-MAY BE OF ANY <br /> NN <br /> LU _ _ I i (CBC 705.2) APPROVED MATERIALS <br /> -.-- EXTERIOR OPENINGS: UNPROTECTED,SPRINKLERED w <br /> " rolLEr � , , . , 1 1 1014.04 <br /> 10 14.1 S 1 S1 I (CBC TABLE 705.8) NO AREA LIMIT <br /> 104 <br /> a o' - - - e - „ 0 1 .0 F IC E i (20'<_X<25') <br /> MI I OE <br /> -------- I 5 s 6 ' �- - - - - - - <br /> I � -------�-' B 50 � 1 7- <br /> 1- <br /> I <br /> S 15 <br /> I 1 60" 8'x48" <br /> 51 s ° I CORRIDORS: 0 HOURS <br /> I i (CBC TABLE 1020.1) N 7O <br /> I L- - - -- - -- -- I W z <br /> 1014.05-/ \ \ 1 1s'0" i 8. OCCUPANT LOAD: SHOWN ON PLAN <br /> <M> i (CBC TABLE 1004.5) J <br /> --------------- <br /> II 9. TOTAL EGRESS WIDTH SHOWN ON PLAN <br /> I I REQUIRED: = 0 <br /> CY <br /> (CBC 1005.1) a 0 <br /> 44 <br /> 10 14.04 i 10. COMMON PATH OF TWO EXITS OR EXIT ACCESS DOORWAYS FROM A SPACE SHALL <br /> ' - i EGRESS CBC TABLEAVE6.2.1) B5 PROVIDED WHERE THE COMMON PATH OF TRAVEL EXCEEDS Z <br /> 0'x 1014.04 10 4. 4 ( U z <br /> ' O S'I- ----q, 1 <br /> ----------1--- --- <br /> 48'x48' - - 0 cn 0 Z <br /> I I I � W <br /> + 10 14LIFE SAFETY SYMBOLS LEGEND v J U o <br /> .04 I o <br /> S25 S1 LLJ <br /> 48"x48" 60"x60" ----- <br /> 0 m O � p <br /> HALLWAYL -------- STORAGE I RoomnaROOM NUMBER <br /> 105 10 14.04 112 I 101 LOAD FACTOR Q U <br /> �^^ <br /> ' L______________ S1 48"x48" i60"x60'- - - - s_as1sF00 <br /> 48'x48.. i 1245aF° ROOM AREA VJ Q Z <br /> . . <br /> 1 I NUMBER OF OCCUPANTS a O <br /> I 0„x60"i � J---- <br /> a <br /> o C) rn <br /> Z <br /> COMMON PATH OF EGRESS TRAVEL DISTANCE/ OF- O <br /> EXIT ACCESS TRAVEL DISTANCE ti U <br /> p� <br /> 1014.04 -- 10 14.04-\i' <br /> S1 <br /> I - - - - -- - -- I 49+ EXIT ACCESS(#OF OCCUPANTS) REQUIRED WIDTH OF EXIT COMPONENTS: <br /> I I 0.2"PER OCCUPANT <br /> EXIT(#OF OCCUPANTS) <br /> ❑ 170 MAX OCCUPANTS FOR SINGLE DOOR, pp;Pu bl is School <br /> 49 340 MAX FOR PAIR U.O.N. <br /> I I <br /> I I <br /> 1014.04 ; F.E. 4ORTHERN CALIFORNI <br /> I S1 I FIRE EXTINGUISHER <br /> I I <br /> TA <br /> I I <br /> o N� <br /> F.E.C. F.E.C. <br /> 11 <br /> I - 1 4 0" I <br /> FIRE EXTINGUISHER CABINET <br /> B 15 <br /> I RECESSED SEMI-RECESSED SURFACE MOUNTED <br /> 1 127 F <br /> I � I <br /> I I <br /> f 1044.03 4co Q OCCUPANCY LEGEND Al <br /> S-1 STORAGE A-3-ASSEMBLY <br /> 1 1014.04 <br /> s1 P1 P2 P3 P4 P5 P6 <br /> ISERVERN E EDUCATION B - BUSINESS <br /> I 16 I N <br /> I B 00 , I (1 J) <br /> 1014.04- <br /> 0 14.04 I 2 7 F I <br /> I -------- ----------, z (N) 1014.04 I <br /> S '� � S1 i PLAN TRUE <br /> S1 1014.04 60'x60' <br /> 14. 5 KEYNOTES KEY PLAN NORTH NORTH <br /> � 1 48"x48"; ' f� <br /> I I <br /> 1014.04 i 1014.04 ROOM IDENTIFICATION SIGN <br /> S12 _ _ _ 2s'�° - - - a5 1014.05 RESTROOM SIGN <br /> 1014.04 I 1014.06 TACTILE EXIT SIGN <br /> S1 i <br /> 1014.08 ASSITIVE LISTENING SIGN <br /> 1014.09 OCCUPANT LOAD SIGN V <br /> ® <br /> 1014.13 RESTROOM DOOR SIGNAGE <br /> ER HEATER STORAGE 1044.03 FIRE EXTINGUISHER CABINET, FULLY-RECESSED <br /> 13 <br /> 1 S-1 300 1044.04 FIRE EXTINGUISHER CABINET,SURFACE-MOUNTED * L 2 <br /> 37 SF 10 44.05 KITCHEN FE TYPE K PER C.F.0 906.4&904.12.5.2,SURFACE MOUNTED <br /> 1 � 10-31-21 Q <br /> RENEWAL DATE <br /> I I <br /> SIGNAGE LEGEND 9�FOF CAS-`�°�� <br /> I I <br /> IimI <br /> L-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------J <S-l > ROOM IDENTIFICATION SIGN-SEE 7/G0.31 <br /> S2 RESTROOM SIGN-SEE 13/G0.31 <br /> S15 RESTROOM DOOR SIGNAGE-SEE 15/G0.31 CLIENT <br /> KIPP:PUBLIC SCHOOLS NORTHERN CALIFORNIA <br /> S18 OCCUPANCY SIGN SEE 19/G0.31 PROJECT NUMBER <br /> S19 ASSISTIVE LISTENING SIGN-SEE 20/G0.31 P2102201 AR <br /> S20 EXIT ROUTE SIGN-SEE 6/G0.31 DATE 07/02/2021 <br /> O S21 EXIT SIGN-SEE 6/G0.31 DRAWN BY: DR CHKED BY: CK <br /> O <br /> 00 REVISIONS <br /> a) # DESCRIPTION DATE <br /> a <br /> I <br /> N <br /> al <br /> N <br /> A <br /> co <br /> U CONSTRUCTION DOCUMENTS <br /> a <br /> Y <br /> <I <br /> Q BUILDING DATA & <br /> r <br /> 0 <br /> NCODE REVIEW <br /> CD Q <br /> N M <br /> 0- <br /> CU <br /> (U ~ <br /> U O N <br /> O � <br /> N o <br /> �I N 1 BUILDING "A1 " <br /> 0 ti SCALE: 1/4"= 1'-0" 1 0 , 20 <br />