My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SIKORSKY
>
5000
>
2800 - Aboveground Petroleum Storage Program
>
PR0541901
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/10/2022 7:59:47 AM
Creation date
1/11/2022 10:50:34 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0541901
PE
2832
FACILITY_ID
FA0016555
FACILITY_NAME
ATLANTIC AVIATION
STREET_NUMBER
5000
STREET_NAME
SIKORSKY
STREET_TYPE
St
City
STOCKTON
Zip
95206
APN
17726034
CURRENT_STATUS
01
SITE_LOCATION
5000 Sikorsky St
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S A N J 0 A Q I I I Irl Environmental Health Department <br /> CCUNT <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> ATLANTIC AVIATION 5000 Sikorsky St, STOCKTON January 10, 2022 <br /> SPCC Plan Requirements for Onshore Facilities(excluding production facilities) <br /> 720 CFR 112.8(d)(1) Failed to take corrective action on buried piping when exposed for any reason ❑V ❑R ❑COS <br /> 721 CFR 112.8(d)(1) Failed to provide corrosion protection for buried piping ❑V ❑R ❑COS <br /> 722 CFR 112.8(d)(2) Failed to cap/blank-flange connection at transfer point and mark its origin if not in service ❑V ❑R ❑COS <br /> 723 CFR 112.8(d)(3) Failed to design pipe supports to minimize abrasion/corrosion and to allow for expansion/contraction ❑V ❑R ❑COS <br /> 724 CFR 112.8(d)(4) Failed to regularly inspect aboveground valves,piping,and appurtenances ❑V ❑R ❑COS <br /> 725 CFR 112.8(d)(4) Failed to conduct integrity and leak testing on buried piping any time it is worked on ❑V ❑R ❑COS <br /> 726 CFR 112.8(d)(5) Failed to adequately warn vehicles entering facility to protect piping and other transfer operations ❑V ❑R ❑COS <br /> 727 CFR 112.7(a)(1), Plan failed to adequately describe overfill prevention methods for each container ❑V ❑R ❑COS <br /> 112.8(c)(8) <br /> Other Violations <br /> 4010 See below Unlisted Administration/Documentation violation ❑V ❑R ❑COS <br /> 4020 See below Unlisted Training violation ❑V ❑R ❑COS <br /> 4030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 4040 See below Unlisted Release/Leaks/Spills violation ❑V ❑R ❑COS <br /> 4050 See below Unlisted Abandonment/Illegal Disposal/Unauthorized Treatment violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 610 CFR 112.7(a)(3vi), 112.7(a4)Plan failed to adequately detail information and procedures for reporting a discharge. <br /> OBSERVATION: The Spill Prevention, Control, and Countermeasure(SPCC) Plan does not adequately discuss <br /> procedures for reporting a discharge.A facility response coordinator was not included in the list of emergency <br /> contacts.The phone number for EHD was incorrect. <br /> REGULATION GUIDANCE: The SPCC plan shall include: (vi)Contact list and phone numbers for the facility <br /> response coordinator, National Response Center, cleanup contractors with whom you have an agreement for <br /> response, and all appropriate Federal, State, and local agencies who must be contacted in case of a discharge as <br /> described in § 112.1(b). <br /> (4)Unless you have submitted a response plan under§ 112.20, provide information and procedures in your Plan to <br /> enable a person reporting a discharge as described in § 112.1(b)to relate information on the exact address or <br /> location and phone number of the facility;the date and time of the discharge,the type of material discharged; <br /> estimates of the total quantity discharged; estimates of the quantity discharged as described in§ 112.1(b);the <br /> source of the discharge; a description of all affected media;the cause of the discharge; any damages or injuries <br /> caused by the discharge; actions being used to stop, remove, and mitigate the effects of the discharge;whether an <br /> evacuation may be needed; and, the names of individuals and/or organizations who have also been contacted. <br /> CORRECTIVE ACTION: This was corrected on site. <br /> This is a minor violation. <br /> FA0016555 PR0541901 SCO01 01/10/2022 <br /> EHD 28-01 Rev.12/06/2021 Page 4 of 6 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.