Laserfiche WebLink
Site: l of w clo� FVim" <br /> �S Appendix B Date: <br /> 71 SO Overfill Valve in Tank Shut off Level Worksheet Tank ID Tester DW <br /> Important: This is meant to be supplemental worksheet and not a substitute to following the installation <br /> manual instructions. All length measurements are in inches. Please contact the Authority Having Jurisdic- <br /> tion (AHJ) and review local,state,and national codes to determine the regulatory requirements governing <br /> shut-off capacity in your region,as well as take into account other considerations such as extreme tank tilt. <br /> Take the following measurements with the valve in- <br /> stalled in the tank: <br /> Distance from the 71 SO inlet tube flange to the cast <br /> lug in the 71 SO body(see figures),upper tube length. <br /> Note: the Upper Tube Length must be at least 16"to in- <br /> clude the protective bend in the tube. <br /> r <br /> Distance from the 71 SO inlet tube flange to the top and <br /> hnttom of lower tube,valve length. 101, <br /> AV)=�� 125 (D' <br /> ►ZS <br /> a Upper y <br /> (U) - ��� Tube <br /> Distance from the 71 SO inlet tube flange to the bottom <br /> tank. Note: If a tank bottom protector is present it <br /> ' add this thickness to dimension <br /> 611 &61TF),rnodels add 0.6") (W)Valve <br /> (B) _ - 225 ' L Length, <br /> bottom of <br /> From the tank calibration chart provided by tank manu- cut <br /> facturer find the dipstick number(Y) which corresponds <br /> to the 100%volume. (B) <br /> (Y) _ <br /> To Tank1411 <br /> t <br /> (Y) <br /> 1. To determine shut-off percentage: Tank <br /> Subtract upper tube length (D)from distance to tank (U)Valve Chart <br /> bottom (B) Length, 100% <br /> (X) _(B) -(D)-2" _ t b ,!Z rU top of cut Volume <br /> k <br /> Dipstick <br /> Using the tank calibration chart provided by the tank <br /> manufacturer determine the tank capacity at the cal- <br /> culated (X)dimension and the 100%volume (Y) tank <br /> (X) tank capacity in gallons= <br /> (Y)tank capacity in gallons= <br /> (X) capacity/(Y)capacity x100= D 1`' <br /> Note: The overfill valve must be installed per AHJ require- <br /> ments and all applicable local,state,and national codes. If <br /> the overfill valve is set above the allowable shut-off percent- <br /> age the overfill valve must be removed and replaced. For <br /> reference 40 CFR part 280 Subpart B Section 280.20 overfill <br /> valves should be set to a maximum of 95%. <br /> 21 <br />