Laserfiche WebLink
i <br /> Ip <br /> a SPANNER LIGHTS <br /> J SEAL (TYP.) <br /> CD <br /> I U_ DISPENSER ttC <br /> N� Q A tl') <br /> U N¢ BUILDING WALLEn <br /> n <br /> I <br /> PVC COATED RIGiD CONDUIT j <br /> ❑ ❑ ❑ PVC CONDUIT LO <br /> tt') <br /> PVC TO METAL CONDUIT N <br /> COUPLER (TYP.) <br /> J J <br /> N PVC COATED RIGID STEEL <br /> CONDUIT <br /> CONDUIT ENTRY TO DISPENSER co <br /> PER DISPENSER MANUFACTURER. O � <br /> SEAL PER N.E.C. CU * <br /> NOTES: DISPENSER SUMP <br /> CLASS 1 , 1. THREADED PVC COATED RiGID METAL CONDUIT SHALL BE USED FOR THE S <br /> LAST 2 FEET OF UNDERGROUND RUN TO EMERGENCE PER N.E.C. 514. cn <br /> DIVISION 2 2. UNDERGROUND PVC CONDUIT SHALL BE USED ONLY AS ALLOWED BY N.E.C. 514-8, O <br /> LOCATION EXCEPTION NO, 2 AND APPLICABLE LOCAL CODES. VERIFY SUITABILITY WITH ALL <br /> APPROPRIATE AGENCIES. PVC CONDUIT SHALL BE SCHEDULE 40 OR HEAVIER WITH <br /> B <br /> ALL PORTIONS BURIED A MINIMUM 2 FEET BELOW GRADE. <br /> CLASS 1 , CONDUIT STUB -- UP <br /> DIVISION 1 <br /> LOCATION F_g SCALE: NTS <br /> I � a <br /> DISP. <br /> PZ=208.5' C <br /> C DISP. <br /> C o 0 <br /> A <br /> 'j O TANK FILL 1 _ PLAN <br /> A C I I p CLASS 1 , <br /> CLASS 1 , pK DIVISION 1 <br /> Cr <br /> n bm <br /> DIVISION 2 o Q a ° 0 000 <br /> LOCATION O <br /> 'P ' N 0 ¢ JUNCTION BOX (TYP.) <br /> o J © LOCATE PER MANUFACTURER'S <br /> nEM M <br /> o J SPECIFICATIONS <br /> l� <br /> C ° ewsna o-sra+z I <br /> i <br /> i <br /> E UNION CROUSE HINDS <br /> TURBINE SUMP I ELEVATION CAT. #UNY OR EQUAL (TYP) <br /> 13 <br /> SEAL FITTING, CROUSE—HINDS <br /> CLASS 1 , <br /> DIVISION 1 GAT. #EY5 OR EQUAL (TYP) <br /> � � <br /> CONDUIT ENTRY TO DISPENSER <br /> PER DISPENSER MANUFACTURER. <br /> (TYP. ALL) N.E.G. <br /> !`COTES: SEAL PER <br /> o IjEE <br /> ?I 04 <br /> VERIFY MANUFACTURER'S DISPENSER DIMENSIONS, MODEL, AND JUNCTION BOX <br /> O E ID O I Q II LOCATIONS PRIOR TO STUBBING CONDUITS. <br /> !I CLASS 1 , DIVISION 1 0 I VERIFY ORIENTATION OF DISPENSERS PRIOR TO STUBBING CONDUITS. <br /> AT DISPENSER SUMPS <br /> 1 <br /> AND INSIDE DISPENSER <br /> DISPENSER CONDUIT <br /> (TYP. AT ALL DISPENSER II F—$ SCALE: NTS <br /> LOCATIONS) N.E.C. HAZARDOUS AREA NOTES <br /> DI A TYPICAL N.E.G. ARTICLE 514 CLASS 1 LOCATION (UNDERGROUND TANK - FILL OPENING) <br /> q O EXTENT OF CLASS 1, GROUP D, DIVISION 1 LOCATION: <br /> } or 2Anpit, <br /> box.d locor atiace on.below grade level, any part of which is within the Division 1 <br /> EXTENT OF CLASS 1, GROUP D. DIVISION 2 LOCATION: <br /> L _ _ _ _ _ _ — T - Up to 18 inches above grade level within a horizontal radius of 10 feetfram a loose <br /> fill connection and within a horizontal radius of 5 feet from a tight fill connection. <br /> I OTYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (UNDERGROUND TANK - VENT-DISCHARGING UPWARD) <br /> EXTENT Within 3CfeetS1.of open end nd sof lvenit, extending In all directions. <br /> EXTENT OF CLASS 1, GROUP 0, DIVISION 2 LOCATION: <br /> Space between 3 feet and 5 feet of open and of vent, extending in all directions. <br /> OTYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (REMOTE PUMP - OUTDOOR) <br /> C EXTENT OF CLASS 1, GROUP D, DI1ASION 1 LOCATION: <br /> Any pit, box, or space below grade level If any part is within a horizontal distance <br /> of 10 feet from any edge of pump. <br /> EXTENT OF CLASS 1, GROUP 0, DIVISION 2 LOCATION: <br /> Within 3 feet of any edge of pump, extending in all directions, Also up to 18 Inches <br /> above grade level within 10 feet horizontally from any edge of pump. <br /> TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (DISPENSING DEVICE - PITS) <br /> © EXTENT OF CLASS 1, GROUP D, DIVISION 1 LOCATION: <br /> Any pit, box, or space below grade level, any part of which is within the Division 1 <br /> or 2 classified location. <br /> TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (DISPENSING DEVICE - DISPENSER) Z <br /> E EXTENT OF CLASS 1, GROUP D, DIVISION 1 LOCATION: W <br /> Space classification inside the dispenser enclosure is covered in ANSI/UL 87, <br /> "Power Operated Dispensing Devices for Petroleum Products." <br /> OTYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (DISPENSING DEVICE - DISPENSER) W <br /> EXTENT OF CLASS 1, GROUP D, DIVISION 2 LOCATION: <br /> Within 18 inches horizontally in all directions extending to grade from (1) the w <br /> dispenser enclosure or (2) that portion of the dispenser enclosure containing <br /> TYPICAL CLASS 1 D I VI I S I O N 1 1 liquid handling components. Space classification inside the dispenser enclosure J J <br /> 0—is covered In ANSI/UL 87, "Power Operated Dispensing Devices for Petroleum <br /> Products." W <br /> 11 <br /> AND 2 H AZA R D O U S AREA PLAN o 10 20 40 so G TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (DISPENSING DEVICE - OUTDOOR) U LL L'i Q <br /> SCALE: 1"=20' Q EXTENT OF CLASS 1, GROUP D, DIVISION 2 LOCATION: <br /> Up to 18 inches above grade level within 20 feet horizontally of any edge of enclosure. <br /> SCALE: 1 It= 20 , r W CD � <br /> NOTES ~ U) �o 0 <br /> CONCRETE U w p W (Y <br /> OR ASPHALT 1. ALL CONDUITS TO EXISTING TANKS ARE EXISTING. RECONNECT EXISTING CONDUITS TO NEW DISPENSERS. 1 <br /> COVER AT GRADE U �-- <br /> U4D8 QROIIM CONUff 800 DLU LTJ o Q 0000 J <br /> DRAWN BY:. <br /> REVIEWED BY: <br /> CONDUIT CONDUCTOR CONDUIT ROUTING REMARKS DATE: 04.12.2022 <br /> NUMBER SIZE TYPE NO. SIZE TYPE FROMTO JOB NO: 21100042.2 <br /> 24 MIN. BACKFILL MATERIAL: (D 1" PVC 6 BELDEN #8760 TLS 350 ANNULAR SPACE MONITORING <br /> / MONITOR PANEL MONITOR J-BOX <br /> PEA GRAVEL (TYP.) O 3/4" PVC 2 BELDEN #8750 ANNULAR SPACE TANK FILL SUMP MONITORING <br /> BELOW CONCRETE OR MONITOR J-Box <br /> ASPHALT GRADE COVER, ANNULAR SPACE TANK TURBINE MONITORING <br /> 1" PVC 4 BELDEN #8760 MONITOR J--BOX SUMP <br /> TOP 01 <br /> CONDUIT o - - - . . �' 2+G #12 RUN < 100' <br /> `:/ 3/4" RMC +G 10 THIN CIPS PUMP MOTOR <br /> MIN. RUN > 100' <br /> O 3/4" PVC 3 BELDEN #8760 ANNULAR SPACE VENT RISER MONITORING <br /> MONfTOR J-BOX <br /> 3„ MIN. 1„ <br /> MIN. <br /> NOTE: <br /> 1. BACK FILL AND COMPACTION FOR ALL. CONDUIT TRENCHES TO MEET, STATE, CITY, <br /> COUNTY AND LOCAL REQUIREMENTS. SHEET <br /> 2. BACKFILL AND COMPACTION FOR SERVICE LATERAL CONDUIT TRENCH TO MEET <br /> LOCAL ELECTRIC UTILITY COMPANY REQUIREMENTS. IF SOIL IS NOT ROCK FREE, <br /> ADD 4" TO DEPTH OF SERVICE LATERAL CONDUIT TRENCH. Ewl <br /> 3 ENCH DETAILS <br /> F-9 SCALE: NTS <br />