Laserfiche WebLink
HIGH PRODUCT R 2:PREMIUM <br /> % MAX 95.0TYPE: <br /> LIQUID SENSOR SETUP <br /> (GALLONS) 3800 _ _ _ _ _ _ _ _ _ _ _ � • STANDARD <br /> NORMALLY CLOSED <br /> • OVERFILL LIMIT ` L 1 :REG STP <br /> MAX '30.0 . TRI-STATE (SINGLE FLOAT) TANK #: 2 <br /> (GALLONS) .3600 CATEGORY :, STP SUMP <br /> DELIVERY LIMIT 4k LIQUID SENSOR ALMS <br /> % MAX 10.0 L 2:PREMIUM STP L 2:FUEL ALARM <br /> (GALLONS) 400 TRI-STATE (SINGLE FLOAT) L 2:SENSOR OUT ALARM <br /> LOW PRODUCT <br /> CATEGORY : STP SUMP L 2:SHORT ALARM <br /> VOLUME 500 ISD SITE ALARMS <br /> L 3:DIESEL STP ISD GROSS PRES FAIL <br /> LEAK ALARM LIMIT: 99 TRI-STATE (SINGLE FLOAT) ISD DEGRD PRES FAIL <br /> SUDDEN LOSS LIMIT: 99 CATEGORY : STP SUMP ISD VAPOR LEAK FAIL <br /> TANK TILT 0.00 ISD VP PRES FAIL <br /> PROBE OFFSET 0.00 ISD VP STATUS FAIL <br /> L 4:REG ANNULAR ISD SETUP FAIL <br /> TRI-STATE (SINGLE FLOAT) ISD SENSOR OUT FAIL <br /> SIPHON MANIFOLDED TANKS CATEGORY : ANNULAR SPACE <br /> T#: NONE ISD HOSE ALARMS <br /> LINE MANIFOLItD TANKS ALL:GROSS COLLECT FAIL <br /> T#: NONE ALL:DEGRD COLLECT FAIL <br /> L 5:PREM-DIESEL ANNULAR ALL:FLOW COLLECT FAIL <br /> LEAK MIN PERIODIC: 0% 'TRI-STATE (SINGLE FLOAT) PMC ALARMS <br /> 0 CATEGORY ANNULAR SPACE VP EMISSIONS FAIL <br /> PERIODIC TEST TYPE VP PRESSURE FAIL <br /> STANDARD VP DUTY CYCLE FAIL <br /> PMC SETUP FAIL <br /> PERIODIC TEST FAIL <br /> ALARM DISABLED R 3:DIESEL <br /> TYPE: <br /> GROSS TEST FAIL STANDARD <br /> ALARM DISABLED NORMALLY CLOSED <br /> PER TEST AVERAGING: OFF TANK. #: 3 <br /> TANK TEST NOTIFY: OFF <br /> OUTPUT RELAY SETUP LIQUID SENSOR ALMS <br /> TNK TST SIPHON BREAKOFF _ _ - - - - - _ - - - - L 3:FUEL ALARM <br /> -L 3:SENSOk OUT ALARM <br /> DELIVERY DELAY 1 MIN R 1 :REG L 3:SHORT ALARM <br /> PUMP THRESHOLD 10.00% TYPE: <br /> STANDARD <br /> NORMALLY CLOSED <br /> TANK #: 1 <br /> LIQUID SENSOR ALMS <br /> L 1 :FUEL ALARM <br /> L 1 :SENSOR OUT ALARM <br /> L 1 :SHORT ALARM RECONCILIATION SETUP <br /> ISD SITE ALARMS - - - - - - - - - -- - - <br /> LEAK TEST METHOD ISD GROSS PRES FAIL <br /> ISD DEGRD PRES FAIL <br /> TEST ON DATE : ALL TANK EDIM 1 : G <br /> APR 26, '2020 ISD VAPOR LEAK FAIL AUTOMATIC DAILY CLOSING <br /> START TIME : DISABLED" ISD VP PRES FAIL TIME: 2:00 AM <br /> TEST RATE :0.20 GAL/HR ISD VP STATUS FAIL <br /> DURATION 2 HOURS ISD SETUP FAIL AUTO SHIFT #1 CLOSING <br /> ISD SENSOR OUT FAIL TIME: DISABLED <br /> TST EARLY STOP:DISABLED ?SD HOSE ALARMS <br /> ALL:GROSS COLLECT FAIL AUTO SHIFT #2 CLOSING Y <br /> LEAK TEST REPORT FORMAT ALL:DEGRD COLLECT FAIL TIME: DISABLED <br /> NORMAL ALL:FLOW COLLECT FAIL <br /> AUTO SHIFT #3 CLOSING <br /> PlC ALARMS TIME: DISABLED <br /> +P EMISSIONS FAIL <br /> VP PRESSURE FAIL AUTO SHIFT #4 CLOSING <br /> VP DUTY CYCLE FAIL TIME: 7:00 AM <br /> PMC SETUP FAIL <br />