My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PELTIER
>
4740
>
2800 - Aboveground Petroleum Storage Program
>
PR0515786
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/13/2022 10:25:34 AM
Creation date
1/13/2022 10:21:23 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0515786
PE
2832
FACILITY_ID
FA0010337
FACILITY_NAME
PAUL E VAZ TRUCKING INC
STREET_NUMBER
4740
Direction
E
STREET_NAME
PELTIER
STREET_TYPE
RD
City
ACAMPO
Zip
95220
APN
01704021
CURRENT_STATUS
01
SITE_LOCATION
4740 E PELTIER RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S A N J 0 A Q I I I Irl Environmental Health Department <br /> CCUN r <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> PAUL E VAZ TRUCKING INC 4740 E PELTIER RD,ACAMPO December 27, 2021 <br /> SPCC Plan Requirements for Onshore Facilities(excluding production facilities) <br /> 718 CFR 112.8(c)(10) Failed to promptly correct visible discharges and/or remove accumulations of oil in diked areas ■V ❑R ❑COS <br /> 719 CFR 112.8(c)(11) Failed to locate properly or provide sufficient secondary containment for mobile/portable containers ■V ❑R ❑COS <br /> 720 CFR 112.8(d)(1) Failed to take corrective action on buried piping when exposed for any reason ❑V ❑R ❑COS <br /> 721 CFR 112.8(d)(1) Failed to provide corrosion protection for buried piping ❑V ❑R ❑COS <br /> 722 CFR 112.8(d)(2) Failed to cap/blank-flange connection at transfer point and mark its origin if not in service ❑V ❑R ❑COS <br /> 723 CFR 112.8(d)(3) Failed to design pipe supports to minimize abrasion/corrosion and to allow for expansion/contraction ❑V ❑R ❑COS <br /> 724 CFR 112.8(d)(4) Failed to regularly inspect aboveground valves,piping,and appurtenances ❑V ❑R ❑COS <br /> 725 CFR 112.8(d)(4) Failed to conduct integrity and leak testing on buried piping any time it is worked on ❑V ❑R ❑COS <br /> 726 CFR 112.8(d)(5) Failed to adequately warn vehicles entering facility to protect piping and other transfer operations ❑V ❑R ❑COS <br /> 727 CFR 112.7(a)(1), Plan failed to adequately describe overfill prevention methods for each container ❑V ❑R ❑COS <br /> 112.8(c)(8) <br /> Other Violations <br /> 4010 See below Unlisted Administration/Documentation violation ❑V ❑R ❑COS <br /> 4020 See below Unlisted Training violation ❑V ❑R ❑COS <br /> 4030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 4040 See below Unlisted Release/Leaks/Spills violation ❑V ❑R ❑COS <br /> 4050 See below Unlisted Abandonment/Illegal Disposal/Unauthorized Treatment violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 112 CFR 112.20(e) Failure to complete and maintain a Substantial Harm Criteria certification. <br /> OBSERVATION: The facility failed to complete and maintain (at the facility)the Substantial Harm Criteria <br /> certification form. <br /> REGULATION GUIDANCE: (e) If the owner or operator of a facility determines pursuant to paragraph (a)(2)of this <br /> section that the facility could not, because of its location, reasonably be expected to cause substantial harm to the <br /> environment by discharging oil into or on the navigable waters or adjoining shorelines,the owner or operator shall <br /> complete and maintain at the facility the certification form contained in appendix C to this part and, in the event an <br /> alternative formula that is comparable to one contained in appendix C to this part is used to evaluate the criterion in <br /> paragraph (f)(1)(ii)(B)or(f)(1)(ii)(C)of this section,the owner or operator shall attach documentation to the <br /> certification form that demonstrates the reliability and analytical soundness of the comparable formula and shall <br /> notify the Regional Administrator in writing that an alternative formula was used. <br /> CORRECTIVE ACTION: Complete and maintain, at the facility,the Substantial Harm Criteria certification form. <br /> Submit proof of correction to the EHD. <br /> This is a Class II violation. <br /> FA0010337 PR0515786 SCO01 12/27/2021 <br /> EHD 28-01 Rev.12/06/2021 Page 4 of 14 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.