My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1240
>
2200 - Hazardous Waste Program
>
PR0540944
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:32 AM
Creation date
1/14/2022 3:56:57 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0540944
PE
2220
FACILITY_ID
FA0023431
FACILITY_NAME
SALLY BEAUTY SUPPLY #3634
STREET_NUMBER
1240
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
St
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
1240 W 11TH St
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
129
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FA0023431 PRO540944 SCO01 01/07/2019 <br />EHD 22-01 Rev. 09/22/16 Page 2 of 9 Small Quantity Hazardous Waste Generator OIR <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sictov.org/ehd <br />Small Quantity Hazardous Waste Generator Inspection Report <br />Facility Name: <br />SALLY BEAUTY SUPPLY <br />Facility Address: <br />1240 W ELEVENTH St, TRACY <br />Date: <br />January 07, 2019 <br />Treatment, Transport and Disposal <br />207 <br />HSC 25144.6(b) <br />Failure to properly manage reusable soiled textile materials <br />❑ V <br />❑ R <br />❑ COS <br />208 <br />HSC 25200.3.1(c) <br />Failure of laboratory to comply with hazardous waste treatment requirements <br />❑ V <br />❑ R <br />❑ COS <br />209 <br />CCR 66262.34(d)(2) <br />Failure to remove all hazardous waste from tanks, containers and containment upon facility closure <br />Preparedness and Prevention <br />❑ V <br />❑ R <br />❑ COS <br />301 <br />CCR 66262.34(d)(2) <br />Facility not maintained to minimize the release of a hazardous waste <br />❑ V <br />❑ R <br />❑ COS <br />302 <br />CCR 66262.34(d)(2) <br />Failed to maintain required emergency equipment <br />❑ V <br />❑ R <br />❑ COS <br />303 <br />CCR 66262.34(d)(2) <br />Failed to maintain all communication or alarm systems, spill control, or decontamination equipment <br />❑ V <br />❑ R <br />❑ COS <br />304 <br />CCR 66262.34(d)(2) <br />Failed to maintain adequate aisle space for unobstructed response to emergencies <br />❑ V <br />❑ R <br />❑ COS <br />Container Management <br />401 <br />CCR 66262.34(d)(2) <br />Failed to store hazardous waste in a container that is in good condition <br />❑ V <br />❑ R <br />❑ COS <br />402 <br />CCR 66262.34(d)(2) <br />Failed to store hazardous waste in a compatible container <br />❑ V <br />❑ R <br />❑ COS <br />403 <br />CCR 66262.34(d)(2) <br />Failed to keep hazardous waste containers closed except when adding or removing hazardous waste <br />❑ V <br />❑ R <br />❑ COS <br />404 <br />CCR 66262.34(d)(2) <br />Failed to inspect hazardous waste storage areas at least weekly <br />❑ V <br />❑ R <br />❑ COS <br />405 <br />CCR 66262.34(d)(2) <br />Failed to manage incompatible wastes in containers properly <br />❑ V <br />❑ R <br />❑ COS <br />406 <br />CCR 66261.7 <br />Contaminated container not marked with date emptied or managed within one year of being emptied <br />❑ V <br />❑ R <br />❑ COS <br />407 <br />CCR 66262.34(e)(1)(A) <br />Satellite accumulation container not located near point of generation or under control of operator <br />❑ V <br />❑ R <br />❑ COS <br />408 <br />CCR 66262.34(e)(2) <br />Satellite accumulation exceeded 55 gallons of HW (or one quart of acutely HW) per waste stream <br />Tank Management <br />❑ V <br />❑ R <br />❑ COS <br />501 <br />CCR 66262.34(4)(2) <br />No overfill prevention device on continuously fed hazardous waste tank <br />❑ V <br />❑ R <br />❑ COS <br />502 <br />CCR 66262.34(d)(2) <br />Tank system inspections of discharge systems, monitoring equipment, and tank levels not done daily <br />❑ V <br />❑ R <br />❑ COS <br />503 <br />CCR 66262.34(d)(2) <br />Tank system inspections of construction materials, fixtures, and surrounding areas not done weekly <br />❑ V <br />❑ R <br />❑ COS <br />504 <br />CCR 66262.34(d)(2) <br />Failed to maintain at least two feet of freeboard in uncovered tank with no secondary containment <br />❑ V <br />❑ R <br />❑ COS <br />505 <br />CCR 66262.34(f) <br />Failed to completely label stationary hazardous waste tanks <br />❑ V <br />❑ R <br />❑ COS <br />19 <br />Labeling and Storage <br />601 <br />CCR 66262.34(d) <br />Stored hazardous waste onsite greater than 180 days <br />❑ V <br />❑ R <br />❑ COS <br />602 <br />CCR 66262.34(e)(1)(B) <br />Stored satellite accumulated waste on site longer than one year or 180 days after fill date <br />❑ V <br />❑ R <br />❑ COS <br />603 <br />CCR 66262.34(e)(1)(C) <br />Failed to mark initial accumulation start date on satellite containers <br />❑ V <br />❑ R <br />❑ COS <br />604 <br />CCR 66262.34(e)(3) <br />Failed to mark satellite containers with date filled within three days <br />❑ V <br />❑ R <br />❑ COS <br />605 <br />CCR 66262.34(f) <br />Failed to completely label containers or portable tanks of hazardous waste <br />■ V <br />❑ R <br />❑ COS <br />606 <br />CCR 66266.81(a)(3) <br />Failed to meet lead acid battery storage requirements for hazardous waste management exemption <br />❑ V <br />❑ R <br />❑ COS <br />607 <br />CCR 66266.81(b) <br />Damaged lead acid batteries not properly managed and labeled <br />❑ V <br />❑ R <br />❑ COS <br />608 <br />CCR 66266.130 <br />Failed to properly manage used oil and fuel filters <br />❑ V <br />❑ R <br />❑ COS <br />609 <br />HSC 25143.2, 25143.9 <br />Failed to meet requirements for claimed excluded recyclable materials <br />❑ V <br />❑ R <br />❑ COS <br />610 <br />CCR 66262.34(b)(1) <br />Stored acutely or extremely hazardous waste onsite greater than 90 days <br />❑ V <br />❑ R <br />❑ COS <br />611 <br />HSC 25200.3.1(b) <br />Failure of laboratory to comply with hazardous waste accumulation area requirements <br />❑ V <br />❑ R <br />❑ COS <br />FA0023431 PRO540944 SCO01 01/07/2019 <br />EHD 22-01 Rev. 09/22/16 Page 2 of 9 Small Quantity Hazardous Waste Generator OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.