My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1612
>
2300 - Underground Storage Tank Program
>
PR0231127
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/27/2022 2:30:18 PM
Creation date
1/20/2022 9:06:42 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0231127
PE
2361
FACILITY_ID
FA0003611
FACILITY_NAME
PARKWOODS GAS & FOOD
STREET_NUMBER
1612
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95209
APN
07728002
CURRENT_STATUS
01
SITE_LOCATION
1612 W HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br /> Overfill Prevention Equipment Inspection Report <br /> fi. OVERFILL PREVENTION EQUIPMENT DETAILS <br /> Tank ID (one OPE per column) Diesel <br /> Are both vent and tank riser piping [I Yes r] Yes rl Yes ® Yes <br /> secondarily contained? [] No No ® No ® No <br /> OPE Model oPW <br /> What is the OPE response when El Shut off ® Shut off rl Shut off [M Shutoff <br /> activated? Flow Flow Flow Flow <br /> (Check all that apply.) El Restricts ®Restricts ® Restricts ® Restricts <br /> Flow Flow Flow Flow <br /> ® Audible Audible ® Audible ® Audible <br /> Alarm Alarm Alarm Alarm <br /> El Visual Visual ® Visual ® Visual <br /> Alarm Alarm Alarm Alarm <br /> Are flow restrictors installed on vent piping El Yes* El Yes* ® Yes* 07 Yes* <br /> that may interfere with the OPE operation? F No E] No No r] No <br /> At what level in the tank is the OPE set to <br /> 82.75 <br /> activate? Inches from bottom of tank <br /> What is the percent capacity of the tank at 93% <br /> which the OPE activates? <br /> Is the OPE in proper operating condition to M Yes ® Yes* Yes* Yes* <br /> respond when the stored substance [] No 0 No rl No 3 No <br /> reaches the designated regulatory level? <br /> 7. SUMMARY OF TESTING RESULTS <br /> OPE Inspection Results El Pass FF-1 Pass ® Pass ® Pass <br /> Fail Fail Fail ® Fail <br /> $. COMMENTS <br /> Describe all answers marked "No"or "Fail"and proposed remedy. <br /> List all monitoring equipment either replaced or repaired. <br /> Drop Tube Passed Inspection SR0084916 <br /> * Mark here if: <br /> 07 Flow restrictors interfere with overfill prevention and equipment repairs required. <br /> Additional copies of this page may be attached. <br /> Attach tank chart(s), measurements, calculations, and In-Tank Setup report(s) <br /> Page 2 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.