My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
REMOVAL_2016
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
8476
>
2300 - Underground Storage Tank Program
>
PR0541462
>
REMOVAL_2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/20/2022 10:02:31 AM
Creation date
1/20/2022 9:50:34 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
REMOVAL
FileName_PostFix
2016
RECORD_ID
PR0541462
PE
2361
FACILITY_ID
FA0023769
FACILITY_NAME
FAMILY RESIDENCE OF RODNEY D & LINDA D GAEDE
STREET_NUMBER
8476
Direction
E
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
CURRENT_STATUS
02
SITE_LOCATION
8476 E KETTLEMAN LN
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
99
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAMPLING PROTOCOL FOR ROUTINE TANK REMOVALS <br />The following represents minimum sampling criterion required for closure compliance. Soil samples collected shall be representative of <br />native soils beneath the tank's invert (tank's bottom) at a collection depth not to exceed 2 - 4 feet. If contamination is documented <br />during closure, an Unauthorized Release Notification must be completed and submitted within five (5) working days pursuant to <br />California Health & Safety Code, Section 25295 Samples cannot be combined into a composite sample for analysis in the field <br />or the lab. Each sample must have a set of corresponding analytical results. <br />WATER NOT PRESENT IN THE TANK PIT <br />TANK <br /># <br />TANK SIZE <br />(Gallons) <br />MINIMUM NUMBER <br />of SOIL SAMPLES <br />LOCATION OF SOIL SAMPLES <br />MINIMUM NUMBER of <br />WATER SAMPLES <br />1,000 <br />1 per Tank <br />( *Fill )OR Pump End of Tank UST only, 4 ft. long) <br />2 from wall next to tank <br />1,000-10,000 <br />2 perTank <br />1 at each End of Tank <br />3 <br />> 10,000 <br />3 or More <br />per Tank <br />Ends and Middle OR generally <br />spaced along the length of the Tank <br />PIPING AND STOCKPILE <br />r <br />TANK SIZE <br />(Gallons) <br />MINIMUM NUMBER of <br />SOIL SAMPLES <br />PIPING SOIL SAMPLES 1 Sample every 20 lineal feet No piping. Hand pump o <br />MINIMUM NUMBER of <br />WATER SAMPLES <br />TANK & PIPING STOCKPILE SAMPLES 2 Samples every 50 cubic yards *(Stockpile +/- 3 C'Y <br />WATER IS PRESENT IN TANK PIT <br />TANK <br /># <br />TANK SIZE <br />(Gallons) <br />MINIMUM NUMBER of <br />SOIL SAMPLES <br />LOCATION of SOIL <br />SAMPLES <br />MINIMUM NUMBER of <br />WATER SAMPLES <br />1 1,000 <br />3 perTank <br />Center and Ends OR Sides of Tank <br />2 from wall next to tank <br />1,000 - 10,000 <br />5 perTank <br />< 10,000 <br />3 <br />ends at soil/groundwater <br />1 <br />Ends and Middle and generally spaced <br />along the length of the Tank <br />Single Tank <br />interface & 1 below tank <br />4 from wall next to tank <br />> 10,000 OR <br />ends at soil/groundwater <br />1 <br />Tank Cluster <br />5 or more <br />interface & 1 below each <br />tank <br />SLAB PRESENT IN THE TANK PIT <br />Soil samples shall be obtained beneath the slab within native soils. Penetration through the obstruction will be required in order to <br />collect the samples. (Physical removal of the obstruction will allow sampling according to the above conditions.) <br />TANK <br /># <br />TANK SIZE <br />(Gallons) <br />MINIMUM NUMBER <br />of SOIL SAMPLES <br />LOCATION of SOIL SAMPLES <br />1 1,000 <br />3 perTank <br />Center and Ends OR Sides of Tank <br />1,000 - 10,000 <br />5 perTank <br />Center and Ends OR Sides of Tank <br />> 10,000 <br />5 OR More per Tank <br />Ends and Middle and generally spaced <br />along the length of the Tank <br />Tri -Regional Recommendations <br />Appendix A <br />EH 23 046 (Revised 7/26/2016) <br />Lop of UST) <br />