Laserfiche WebLink
<br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjcehd.com <br /> <br />Environmental Health Department <br /> Linda Turkatte, REHS, Director <br /> Kasey Foley, REHS, Assistant Director <br /> PROGRAM COORDINATORS <br /> Robert McClellon, REHS <br /> Jeff Carruesco, REHS, RDI <br /> Michael Kith, REHS <br />Willy Ng, REHS <br /> Muniappa Naidu, REHS <br /> <br /> <br /> <br /> <br /> <br />03/22/2019 <br /> <br />Julie Delucchi <br />1002 S. Jack Tone Rd. <br />Stockton, CA 95215 <br /> <br /> <br />RE: Well Pump Inspection <br />Well Location: 1002 S. Jack Tone Rd. Stockton, CA Permit #: WP0039413 Inspection Date: 03/22/2019 <br /> <br />The Environmental Health Department recently conducted a water well pump inspection at the above address <br />and found the following issues at the time of the inspection. In order to protect the ground water supply and <br />your water source from potential degradation, please take the associated corrective actions. <br /> <br />☒ Lack of Concrete Pedestal around Wellhead. <br /> (SJC Water Well Standards, Section 4.10. – Surface Seal) Corrective Action: Install a new concrete platform around the wellhead that extends 2 ft. in all <br />direction from the well head. <br />☐ Lack of or Inadequate Sanitary Seal at Wellhead. <br /> (SJC Ord. Code, Title 9, Section 9-1115.5. – Well Regulations) Corrective Action: Install a sanitary seal between casing and well cover plate/seal all gaps and <br />openings. <br />☐ Lack of or Inadequate Sampling Tap. <br /> (SJC Water well Standards, Section 4.13. – Sampling Tap) Corrective Action: Install a non-threaded sampling tap between the wellhead and the check valve <br />or within three (3) feet of the well head. <br />☐ Lack of or Inadequate Backflow Prevention. <br /> (SJC Water Well Standards, Section 4.14. – Backflow Prevention) Corrective Action: Install an approved protective device to prevent backflow and/or back <br />siphonage into a well. <br />☐ Sounding Tube or Air Vent not Sealed. <br /> (SJC Water Well Standards, Section 4.13. – Sounding Tube/Air Vent Pipe) Corrective Action: Sounding Tube or Fill Pipe-Install a watertight, threaded cap at the upper end <br />of the pipe. Air Vent-extend pipe 12 inches above with end inverted in a <br />downward direction and covered with 16-mesh screening. <br />☐ Excessive Vegetation or debris around Wellhead. <br /> (SJC Ord. Code, Section 9-1115.4. – Dangerous/Nuisance) Corrective Action: Remove and maintain debris and vegetation away from well area. <br /> <br /> <br />If you have any questions, contact: Aaron Gooderham, Environmental Health Assistant (209) 468-3442. <br />Please call when work is complete for reinspection. <br /> <br /> <br /> <br />Michael Kith, REHS <br />Program Coordinator