Laserfiche WebLink
oPau'N c'GZ SAN J O A Q U I N Environmental Health Department <br /> COUNTY Jasjit Kang , REHS , Director <br /> c ./.FOGreatness grows <br /> .. .. .- P here . Muniappa Naidu , REHS, Assistant Director <br /> qCRS <br /> PROGRAM COORDINATORS <br /> Robert McClellon , REHS <br /> Jeff Carruesco , REHS , RDI <br /> Willy Ng , REHS <br /> Melissa Nissim , REHS <br /> Steven Shih , REHS <br /> April 8 , 2022 Michelle Henry , REHS <br /> Carrie Miller <br /> Elite IV Contractors <br /> 2535 Wigwam Dr. <br /> Stockton , CA 95205 <br /> Re : Arch Arco AM PM SR0085021 <br /> 4855 S . Hwy 99 East Frontage Rd . , Stockton , CA 95212 <br /> The San Joaquin County Environmental Health Department ( EHD ) has completed the review of the <br /> application for a permit to replace on the underground storage tank ( UST) system at the above noted <br /> address . The San Joaquin County Environmental Health Department ( EHD ) has completed the review <br /> of the application for a permit to do the following on the underground storage tank ( UST) system at the <br /> above noted address : <br /> • Replace the 87 southwest spill container <br /> • Replace all four ( on all three tanks) drop tubes with shut- off valve (flapper) <br /> The permit has been approved with the following conditions : <br /> 1 . Contact the local fire department and the San Joaquin Valley Air Pollution Control District for <br /> any applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work . All new addenda supersede the previous ones . <br /> 3 . Provide written notification to ustt slgov . org to arrange the following inspection appointments <br /> ( a 48 - hour notice is required for inspection appointments ) . <br /> a . Spill bucket test : Verify minimum 5 -gallon capacity and pass a one hour hydrostatic test ( or <br /> equivalent) . Proper drainage must also be verified . <br /> b . Overfill prevention verification : Measurement of drop tubes to verify 95 % tank volume shut <br /> off. Verification of flapper functionality . Ensure that all pertinent tank charts and <br /> calculations are available for review at the time of inspection . <br /> c . Verification that ball float (s ) , if installed , do not interfere with the installed flapper valve . <br /> Please be aware that the facility cannot receive fuel in the 87 , 89 , or 91 tanks prior to the <br /> EHD inspection and approval . <br /> 4 . Any individual performing the work of a service technician must meet the following <br /> qualifications : <br /> a . Possess or be employed by a person who possesses one of several permissible valid , <br /> current contractor' s licenses issued by the Contractors State License Board ( may be issued <br /> to the installation company) , or a Tank Tester' s license issued to the individual by the State <br /> Water Board <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 T 209 468 - 3420 F 209 464 -0138 1 www . sjgov . org/ehd <br />