Laserfiche WebLink
Chevron Monitoring Certification Checklist <br /> Store Number: 201383 Address: 1960 W.11TH STREET @ CORRAL HOLLOW TRACY,CA 95376 <br /> Date:1/20/2022 Technician: Jesus Saldivar Company:TANKNOLOGY INC. <br /> Step Instruction T2 T1 T3 <br /> Product REGULAR SUPREME Diesel <br /> Tank Type Fiberglass Fiberglass Fiberglass <br /> (DW FRP,DW Steel,SW FRP) <br /> 1 Annular Riser Height(measured) 62.00 in. 62.00 in. 62.00 in. <br /> Tank Diameter:(from tank chart, <br /> 2 92.00 in. 92.00 in. 92.00 in. <br /> forexample:118.375",117.75';111';92",etc.) <br /> 3 For FRP tanks,1/2 circumference of the tank 144.44 in. 144.44 in. 144.44 in. <br /> (0.5 X3.14 X tank diam.)OR(q.57 x step 2) <br /> Required annular sensor length: <br /> 4 FRP=Riser+1/2 Circumference=step 1+step 3 206.44 in. 206.44 in. 206.44 in. <br /> Steel=Riser+diameter=step 1+step 2 <br /> Mark&label the required sensor length on <br /> 5 sensor cord.Label should be under the cap& Yes Yes Yes <br /> serve to prevent the cord being pulled too short. <br /> Is tank annular sensor in the correct position? <br /> Yes Yes Yes <br /> 6 FRPTanks:with the marked required length <br /> lining up with the top of the annular riser? Yes Yes Yes <br /> Steel Tanks:sensor touching bottom with slack <br /> above the marked required sensor length? <br /> Are the DW pipe boots pulled back in tank sumps? <br /> 8 (YIN or N/A,note if can't be verified because Yes Yes Yes <br /> clamshell pointing down) <br /> Are tank sump sensors back in their holders and <br /> 9 in the correct position? Yes Yes Yes <br /> (YIN or N/A document with photo) <br /> 7 Approximate gallons of product dispensed for <br /> purging,etc.and returned to tank <br /> Has the Veeder Root Battery been replaced&dated prior to failsafe? Replaced in Last 30 Days <br /> (if battery backup failed,label and leave failed battery on top of console,note in comments and advise your OM) <br /> Has Veeder Root Programming before&after testing been printed&verified? Yes <br /> (especially tank manifolding setup-see Note 2) <br /> Has Veeder Root Programming before&after been attached to the Work Order? Yes <br /> Have all sensor model numbers been verified against the Veeder Root cord label? Yes <br /> Make a note if sensor label missing or illegible,&approx.cord length for-208/-209 with missing labels <br /> Additional Comments: <br /> 409 ANNULARS SENSORS ON THIS SITE. <br /> Note 1: Certain Veeder Root Software versions will automatically revert to the default tank manifold settings anytime the programming is changed,such as when sensors are <br /> temporarily X'ed out,etc. <br />