My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DA VINCI
>
4627
>
2300 - Underground Storage Tank Program
>
PR0231074
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/9/2023 10:43:22 AM
Creation date
1/27/2022 8:37:15 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0231074
PE
2351
FACILITY_ID
FA0002541
FACILITY_NAME
7-ELEVEN INC #20632
STREET_NUMBER
4627
STREET_NAME
DA VINCI
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
11002003
CURRENT_STATUS
01
SITE_LOCATION
4627 DA VINCI DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
50
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A Q A n I Environmental Health Department <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Phone : Date : <br /> 7-ELEVEN INC #20632 ( 209 ) 952-3543 December 13 , 2022 <br /> Facility Address : CERS ID : <br /> 4627 DA VINCI DR, STOCKTON , CA 95207 10165883 <br /> Inspe„tion Contact: Title: Phope: <br /> N ; urs � nrie nv � rahrr�e► c� 1 �o o - � � tc S -yS �a <br /> Inspection Type: Program: <br /> ROUTINE INSPECTION - Operating Permit 2351 - UST FACILITY - 2481 COMPLIANT <br /> Consent For: Consent Given By: <br /> Inspection Photos Sam les Q $ I'iq Yl-! �l � A r(1 So Q Svove �" (7`Y\GL� E' r <br /> 'Service Technician Onsite: Fxp. Opts: Designated Operator: Exp . Date : <br /> d. C Ve. z3 Ser e jAe d s is <br /> ery ce Techni ian Manufacturer's Training : <br /> v I z vm I 2�- 1z3 a p l,U Z 1 <br /> CCR = Title 23 califorrfla Code of Regulations HSC = Health and Safely Code CFR = Code of Federal Regulations <br /> V = Violation R = Repeat violation COS = Corrected on site during inspection <br /> File Review <br /> 101 HSC 25284; CCR Failure to obtain a permit to operate from the EHD including but not limited to unpaid permit fees XV ❑ R o COS <br /> 2711 (d) <br /> 102 CCR 2711 Failure to submit a complete and accurate application for a permit to operate a UST ❑ V ❑ R ❑ COS <br /> 103 CCR 2635(f) , 2636(c) (2) Failure to submit the UST Certification of Installation/Modification ❑ V ❑ R ❑ COS <br /> 104 CCR 2632(d) (1 ) , Failure to submit a complete and accurate UST Monitoring Plan ❑ V ❑ R ❑ COS <br /> 2634(d) <br /> 105 CCR 2632(d) (2) , Failure to submit a complete and accurate UST Response Plan ❑ V ❑ R ❑ COS <br /> 2634(e) <br /> 106 CCR 2632(d) , 2641 (h) Failure to submit and maintain a current facility plot plan / site map ❑ V ❑ R ❑ COS <br /> 107 HSC 25292.2; CCR Failure to submit and maintain complete and current financial responsibility documents V ❑ R ❑ COS <br /> 2711 (a)(11 ) <br /> 108 CCR 2620(b) ; HSC Failure to implement or maintain a written agreement between the UST owner and operator ❑ V ❑ R ❑ COS <br /> 25284(a)(3) <br /> 109 CCR 2715(a) (1 )(B), Failure to submit "Designated Underground Storage Tank Operator Identification Form" within 30 days ❑ V ❑ R ❑ COS <br /> 2715(a)(3) <br /> 110 CCR 2715(a) (1 )(A), Failure to submit the "Underground Storage Tank Statement of Understanding and Compliance Form" ❑ V ❑ R ❑ COS <br /> 2715(a)(2) <br /> 111 CCR 2637, 2638(e) , Failed to notify the EHD 48 hours prior to conducting testing ❑ V ❑ R ❑ COS <br /> 2643(g) <br /> 112 CCR 2638 , 26410), Failure to have properly qualified service technician test leak detection equipment every 12 months ❑ V ❑ R ❑ COS <br /> 2715(f) <br /> 113 CCR 2637(a-d), 2712(b) Failure to conduct secondary containment testing ❑ V ❑ R ❑ COS <br /> (1 )(F) <br /> 114 CCR 2636(f)(3) , 2643(c) Failure to perform line integrity test every 12 months or within 30 days of repair of primary pipe ❑ V ❑ R ❑ COS <br /> (3) <br /> 115 CCR 2638(c) , 2638(d) Failure to submit "Monitoring System Certification Form" within 30 days of completion of the test ❑ V ❑ R ❑ COS <br /> 116 CCR 2637. 1 (d) , Failure to submit the "Spill Container Testing Report Form" within 30 days ❑ V ❑ R ❑ COS <br /> 2637. 1 (e) <br /> 117 CCR 2637(e) , 2637(f) Failed to submit "Secondary Containment Testing Report Form" within 30 days after the test ❑ V ❑ R ❑ COS <br /> 118 CCR 2637.2(d&e) , Failure to submit the "Overfill Prevention Equipment Inspection Report Form" within 30 days ❑ V ❑ R ❑ COS <br /> 2665(a&b) <br /> 119 CCR 2663, 2712(b)(6) Failure to comply with tank lining certification , testing, inspection , and record requirements ❑ V ❑ R ❑ COS <br /> 120 CCR 2631 , 2640. 11 Failure to submit and/or maintain documentation regarding compatibility for UST system components ❑ V ❑ R ❑ COS <br /> 2665, 2711 <br /> FA0002541 PR0231074 SCO01 12/13/2022 <br /> EHD 23-01 Rev. 9/20/2019 Page 1 of 4 Underground Storage Tank Program OIR <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www. sjcehd . com <br />
The URL can be used to link to this page
Your browser does not support the video tag.