My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DA VINCI
>
4627
>
2300 - Underground Storage Tank Program
>
PR0231074
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/9/2023 10:43:22 AM
Creation date
1/27/2022 8:37:15 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0231074
PE
2351
FACILITY_ID
FA0002541
FACILITY_NAME
7-ELEVEN INC #20632
STREET_NUMBER
4627
STREET_NAME
DA VINCI
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
11002003
CURRENT_STATUS
01
SITE_LOCATION
4627 DA VINCI DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
50
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S A N J O A Q U I N Environmental Health Department <br /> u ;v 1 <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name : Facility Address: Date : <br /> 7-ELEVEN INC #20632 4627 DA VINCI DR , STOCKTON December 13 , 2022 <br /> r UST System Observations <br /> 312 HSC 25290.2(d) Monitoring system incapable of detecting entry into secondary containment (Jul 2003-Jun 2004) o V ❑ R o COS <br /> 313 HSC 25290. 1 (d) Monitoring system incapable of detecting entry into secondary containment (post-Jul 2004) ❑ V o R ❑ COS <br /> 314 CCR 2631 (g), 2632(c) Failure to continuously monitor interstitial space with audible-visual alarm system (pre-Jul 2004) ❑ V o R in COS <br /> (2) <br /> 315 HSC 25290. 1 (e) Failure to maintain interstitial space to detect leaks before release to environment (post-Jul 2004) o V ❑ R o COS <br /> 316 CCR 2636 , 2643(c)(1 ) , Failure to install a line leak detector o V o R o COS <br /> 2666(f) <br /> 317 CCR 2636(f)(2) Failure of the line leak detector to detect a 3 . 0 gph leak at 10 psi and restrict or shut off flow o V o R ❑ COS <br /> 318 CCR 2635, 2637. 1 , Failed to meet spill container requirements o V ❑ R o COS <br /> 2665, 2712 <br /> 319 CCR 2635, 2637.22 Failure to comply with overfill prevention equipment requirements ❑ V o R o COS <br /> 2665, 2712 <br /> 320 CCR 2635(c)(1 ) Overfill prevention was overridden o V o R o COS <br /> 321 HSC 25299(a)(9) Leak detection equipment disabled or tampered with o V o R o COS <br /> 322 CCR 2717. 1 (g) Removed, defaced, altered , or otherwise tampered with red tag o V o R o COS <br /> 323 CCR 2717. 1 (f); HSC Deposited or allowed deposit of petroleum or a hazardous substance into a red tagged UST o V o R o COS <br /> 25292. 3(c) <br /> 324 HSC 25292. 3(c)(1 ) (C) Allowed dispensing from a UST that has a red tag affixed to the fill pipe o V o R o COS <br /> 325 CCR 2635, 2636(b) , Failure to comply with the cathodic protection system requirements o V ❑ R o COS <br /> 2662j2712 <br /> 326 CCR 2631 (b&d) , Primary and/or secondary containment not constructed in accordance with the established standards o V ❑ R o COS <br /> 2666(b&e) <br /> 327 CCR 2638(a), 26410) Leak detection equipment not installed/calibrated/operated/maintained per manufacturer instructions ❑ V ❑ R ❑ COS <br /> 328 CCR 2630, 2632, 2643, Equipment or methods used to monitor the UST system are not certified by an independent third-party o V o R o COS <br /> 2644. 1 <br /> 329 CCR 2631 , 1 , 2660(m) UST system not compatible with the substance stored o V in R o COS <br /> 330 CCR 2636(f) , 2666(c) , Failure of emergency generator line leak detector to restrict or shut off flow or trigger an alarm o V o R o COS <br /> 2666(f) <br /> 331 HSC 25281 .6(a) Failure of unburied below-grade emergency generator system to meet exemption conditions ❑ V o R o COS <br /> 332 HSC 25283. 5(a) Failure of unburied below-grade UST system to meet exemption conditions o V ❑ R o COS <br /> 333 CCR 2666(b)(2) Failure to upgrade single-walled pipe to double-walled interstitially monitored pipe when repaired ❑ V o R o COS <br /> 334 CCR 2670(b)(e) (0, Failure to comply with temporary closure requirements o V o R o COS <br /> 2671 <br /> 335 HSC 25298(c) ; CCR Failure to comply with all permanent closure requirements ❑ V o R ❑ COS <br /> 2670, 2672 <br /> 336 CCR 2638(f), 2641 Q) Failure to affix a tag/sticker on each monitoring equipment certified, repaired, or replaced ❑ V ❑ R ❑ COS <br /> Single-Walled Non -Pressurized Piping <br /> 401 CCR 2636(a) (3) , Safe suction piping failed to meet slope, check valve location, or inspection requirements ❑ V o R o COS <br /> 2641 (b) <br /> 402 CCR 2643(d) Failure to conduct monitoring and maintain records for single-walled conventional suction (pre-1984) o V o R ❑ COS <br /> 403 CCR 2643(d) , 2661 (f) Failure to conduct 0. 1 gph integrity test for single-walled conventional suction systems (pre-1984) o V o R o COS <br /> 404 CCR 2643(e) , 2661 (f) Failure to conduct 0. 1 gph test on single-walled gravity piping biennially or post repair (pre-1984) o V o R o COS <br /> FA0002541 PR0231074 SCO01 12/13/2022 <br /> EHD 23-01 Rev. 9/20/2019 Page 3 of 4 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton , California 95205 1 T 209 468-3420 F 209 464-0138 1 www. sjcehd . com <br />
The URL can be used to link to this page
Your browser does not support the video tag.