Laserfiche WebLink
°• Environmental Health Department <br /> �. �J r� SHAWN <br /> t 7Y - L. <br /> Y <br /> ttlir_ ' COUNTY— <br /> Greol less grows he: . . <br /> Underground Storage Tank Program Service Request Inspection Report <br /> Name of Facility: BILLJAR VALERO Date: 11/09/2022 <br /> Address: 153 E ELEVENTH ST, TRACY 95376 <br /> Requestor: AFFORDA TEST,AFFORDA TEST Telephone: (209)744-0112 <br /> Program Element: 2308-UST RETROFIT Request#: SR0085956 <br /> Inspection Type: 298-UST RETROFIT REPAIR INSPECTION <br /> Onsite Service Technician: Edward Stearns ICC Service Tech/Installer Exp. Date: 11/05/2024 <br /> Manufacturer training: FF, 11/08/22 <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> NOTES <br /> On site for inspection: <br /> -Verified drop tubes set at 95%tank volume shut off for 87 main, 87 siphon and 91 tanks <br /> -Verified flapper functionality for 87 main, 87 siphon and 91 tanks <br /> -Verified calculations and tank charts for 87 main, 87 siphon and 91 tanks <br /> -Ball floats absence or location above the flapper could not be verified during the inspection. <br /> Facility is approved to receive fuel in the 87 main, 87 siphon and 91 tanks. <br /> This service request is still considered open until the absence of ball floats are verified or verification that ball floats are located <br /> above the flapper. <br /> If it is found that ball floats are installed and located at or below the flapper,the tanks would not have functional overfill. No fuel <br /> should be deposited into a tank that does not have a functional overfill. <br /> Please schedule an appointment to verify ball floats are not installed or are located above the flapper. Submit inspection <br /> requests in writing to UST@sjgov.org with 48-hour advanced notice. <br /> Ensure Overfill Prevention Equipment test results are submitted to EHD within 30 days to UST@sjgov.org <br /> Ensure CERS overfill prevention method has been updated to reflect new overfill prevention installed today. <br /> To minimize person to person contact EHD is choosing to write the name of person receiving the report instead of having them <br /> sign. Starting September 1, 2018, all in-office CERS help will be provided at the EHD hourly rate($156). To schedule an <br /> appointment, please call (209)468-3420. <br /> The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br /> Safety Code.If a reinspection is required,fees will be assessed at the current hourly rate. <br /> Received by: Name and Title: Emailed to Amandeep Kaur, Environm <br /> EH Specialist: CAROL PRESTO Phone: (209)616-3061 <br /> FA0003709 SR0085956 SC298 11/09/2022 <br /> EHD 23-01 Rev.07/05/2022 Page 1 of 1 Underground Storage Tank Program Service Request Inspection Report <br />