My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
153
>
2300 - Underground Storage Tank Program
>
PR0231389
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:37 AM
Creation date
1/27/2022 8:40:42 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0231389
PE
2361
FACILITY_ID
FA0003709
FACILITY_NAME
BILLJAR VALERO
STREET_NUMBER
153
Direction
E
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23336607
CURRENT_STATUS
01
SITE_LOCATION
153 E ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
102
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> RECEIVED BY EHD VIA EMAIL: <br /> 2/23/2022 <br /> UNDERGROUND STORAGE TANK <br /> SECONDARY CONTAINMENT TESTING REPORT FORM(Page 1 of 6) <br /> Type of Action ❑Installation Test ❑Repair Test ❑Six Month Test 36 Month Test <br /> I. FACILITY INFORMATION <br /> CERS ID Date of Secondary Containment Test <br /> 10181331 9/17/2020 <br /> Business Name(Same as Facility Name or DBA-Doing Business As) <br /> Bili ar Valero <br /> Business Site Address City ZIP Code <br /> 153 East 11 th Street Tracy 95376 <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Test(Print as shown on the ICC Certification) Phone# <br /> Benjamin Duncan (707) 621-0378 <br /> Contractor/Tank Tester L cense# ICC Certification# ICC Cenrfication Expiration Date <br /> Tank Tester License#90-1120 5246802-UT 3/21/2021 <br /> III. SUMMARY OF SECONDARY CONTAINMENT TESTING RESULTS <br /> TANK ID:(By tank number,stored product,etc) A T-1-87-siphon B T-2-87-Master C T-3-91 D <br /> Tank Containment <br /> Tightness Test Result O Pass ❑Fail ❑NA O Pass ❑Fail ❑NA B Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> Product Piping Containment <br /> Tightness Test Result E Pass ❑Fail ❑NA O Pass ❑Fail ❑NA O Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> Communication Test Result ❑Pass ❑Fail O NA ❑Pass ❑Fail E NA ❑Pass ❑Fail B NA ❑Pass ❑Fad ❑NA <br /> Remote Fig Piping Containment <br /> Tightness Test Result ❑Pass ❑Fail E NA ❑Pass ❑Fad O NA ❑Pass ❑Fail B NA ❑Pass ❑Fail ❑NA <br /> Communication Test Result ❑Pass ❑Fail B NA ❑Pass ❑Fail B NA ❑Pass ❑Fail E NA ❑Pass ❑Fail ❑NA <br /> Vent Piping Containment <br /> Tightness Test Result ❑Pass ❑Fail E NA ❑Pass ❑Fail E NA ❑Pass ❑Fail E NA ❑Pass ❑Fail ❑NA <br /> Communication Test Result ❑Pass ❑Fail E NA ❑Pass ❑Fail E NA ❑Pass ❑Fail E NA ❑Pass ❑Fal ❑NA <br /> Vapor Recovery Piping Containment <br /> Tightness Test Result ❑Pass ❑Fail B NA ❑Pass ❑Fail B NA ❑Pass ❑Fail E NA ❑Pass ❑Fal ❑NA <br /> Communication Test Result ❑Pass ❑Fail E NA ❑Pass ❑Fail E NA ❑Pass ❑Fail E NA ❑Pass ❑Fail ❑NA <br /> Turbine/Product Piping Sump <br /> Tightness Test Result E Pass ❑Fail ❑NA E Pass ❑Fad ❑NA B Pass ❑Fal ❑NA ❑Pass ❑Fail ❑NA <br /> Fill Riser Sump <br /> Tightness Test Result ❑Pass ❑Fad B NA ❑Pass ❑Fail E NA ❑Pass ❑Fail B NA ❑Pass ❑Fad ❑NA <br /> VENT/TRANSITION SUMP ID: a b C d <br /> Tightness Test R.esuft ❑Pass ❑Fail E NA ❑Pass ❑Fail E NA ❑Pass ❑Fail E NA ❑Pass ❑Fail ❑NA <br /> UDC ID: 1 182 2 384 3 5&6 4 <br /> Tightness Test Result B Pass ❑Fail ❑NA B Pass ❑Fail ❑NA E Pass ❑Fal ❑NA ❑Pass ❑Fal ❑NA <br /> UDC ID: 5 6 7 8 <br /> Tightness Test Result ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> UDC ID: 9 10 11 12 <br /> Tightness Test Result ❑Pass ❑Fad ❑NA ❑Pass ❑Fad ❑NA I ❑Pass ❑Fad ❑NA ❑Pass ❑Fad ❑NA <br /> All items marked"Fail"or-NA"must be explained in their respective"COMMENTS"section. <br /> IV. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS TESTING <br /> I hereby certify that the secondary containment was tested in accordance with California Code of Regulations,Title 23,Division <br /> 3,Chapter 16,Section 2637 and all the information contained herein Is accurate. <br /> UST Service Technician Signature `/E�4 ✓'�!/tts�cd>►t-� <br /> CERS•Callorna ErMrmnerital Reporting System ID=Ide�,UST=Urxk rground Storage Tank ICC=Irtternaticnal Code Council.NA=Not Applicable.UDC=Under- <br /> Drsperw C twiner! <br />
The URL can be used to link to this page
Your browser does not support the video tag.