My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ESCALON
>
1329
>
2300 - Underground Storage Tank Program
>
PR0231487
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/15/2023 8:21:50 AM
Creation date
1/31/2022 8:47:22 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0231487
PE
2351
FACILITY_ID
FA0000293
FACILITY_NAME
Pershing Holdings, Inc. DBA Esclon Arco
STREET_NUMBER
1329
STREET_NAME
ESCALON
STREET_TYPE
Ave
City
Escalon
Zip
95320
APN
22510003
CURRENT_STATUS
01
SITE_LOCATION
1329 Escalon Ave
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
67
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
c'AN.JOAOLIN <br /> Environmental Health Department <br />(„i)LiNT Y <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Pershing Holdings, Inc. DBA Esclon Arco <br />Facility Address: <br />1329 Escalon Ave, Escalon <br />Date: <br />February 17, 2022 <br />File Review <br />121 HSC 25299(a)(8), <br />25299(b)(7) <br />False statements, representation, or certification made on an application, record, or other document D V R _ COS <br />122 CCR 2712(f) Failure to implement corrections and submit written response within 30 days of receiving the report i i V iR COS <br />On Site Records <br />201 HSC 25293 Failure to maintain UST records to enable the UPA to determine whether the UST is in compliance D V oR oCOS <br />202 CCR 2712(i) Failure to retain a paper or electronic copy of the permit to operate at the facility oV o R o COS <br />203 CCR 2712(b)(1-2) Failure to maintain monitoring records for 36 months and maintenance records for 60 months oV oR a COS <br />204 CCR 2712(b)(6) Failure to maintain records of repairs, lining, and upgrades on site, for the life of the UST oV oR o COS <br />205 CCR 2712(i) Failure to have current UST Monitoring Plan readily accessible at the facility oV oR oCOS <br />206 CCR 2712(i), 2634(e) Failure to have a current UST Response Plan available on site oV oR oCOS <br />207 CCR 2716(f) Failure to maintain designated operator inspection reports and all attachments on site for 36 months oV oR oCOS <br />208 CCR 2716(a-e) Failure to comply with the designated operator inspection requirements V oR aCOS <br />209 CCR 2715(c)(3), <br />2715(c)(4) <br />Failure to maintain a copy of the "Facility Employee Training Certificate" on-site DV oR oCOS <br />210 CCR 2715(c) Failure to provide initial training, train every 12 months, and have a trained employee present oV oR oCOS <br />211 CCR 2715(c)(2) Failure to have or implement a training program approved by the UPA, at an unstaffed facility oV oR oCOS <br />212 CCR 2651; HSC 25294 Failure to record any unauthorized release from primary containment oV oR o COS <br />213 CCR 2650(e), 2652 Failure to notify and submit report of reportable unauthorized release or record release DV oR o COS <br />214 CCR 2712 Failure to comply with UST operating permit conditions oV oR o COS <br />215 CCR 2715 Designated operator, service tech, or installer did not possess current certifications oV oR o COS <br />216 I-1SC 25281.5(b)(2) Failure to meet inspection requirements for marina unburied fuel piping mV oR oCOS <br />217 HSC 25281.5(b)(3) Failure to meet inspection requirements for emergency generator unburied fuel piping DV R HCOS <br />UST System Observations <br />301 HSC 25292.1(a) Failure to operate UST system to prevent unauthorized releases including leaks, spills and overfills o V oR o DOS <br />302 CCR 2630(d), 2641(a) Leak detection equipment not installed/maintained/located to detect leaks at earliest opportunity oV oR oCOS <br />303 CCR 2630(d), 2641(a) Failure to maintain piping to allow liquid to flow into sump (i.e. failure to remove test boots) oV oR o COS <br />304 CCR 2631(a): HSC <br />25290.1(c) <br />Failure to construct, operate, and maintain primary containment as product-tight oV oR o COS <br />305 HSC 25290.1, 25290.2, <br />25291 <br />Failed to maintain secondary containment (e.g. failure of secondary containment testing) oV oR oCOS <br />306 HSC 25291(e) Failure to remove, analyze, and properly dispose of water in secondary containment (pre-Jul 2003) oV oR o COS <br />307 HSC 25290.1(c3), <br />25290.2(c3) <br />Failure to keep water out of the secondary containment system (post-Jul 2003) oV oR o COS <br />308 CCR 2632(c), 2634(d), <br />2636(f) <br />Failure of the leak detection equipment to have an audible and visual alarm oV oR oCOS <br />309 CCR 2666(b)(2), <br />26360)(1) <br />Failure to have continuous monitoring that activates audible-visual alarm or stops flow at dispenser oV oR o COS <br />310 CCR 2636(f)(4) Failure to meet monitoring requirements in lieu of being tightness tested every 12 months oV oR o COS <br />311 HSC 25291(b) Monitoring system incapable of detecting leak into secondary containment (pre-Jul 2003) oV oR a COS <br />FA0000293 PR0231487 SC001 02/17/2022 <br />EHD 23-01 Rev. 12/06/2021 <br />Page 2 of 4 <br /> Underground Storage Tank Program OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 I T 209 468-3420 I F 209 464-0138 I www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.