Laserfiche WebLink
S0 JOA U 1 Environmental Health Department <br /> Hazardous Materials Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> B&C PAINTING SOLUTIONS INC 107 VAL DERVIN PKWY, STOCKTON January 27, 2022 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 5 HSC 25505(a)(1) Failed to electronically submit hazardous materials inventory for all reportable materials on site. <br /> OBSERVATION: 90 gallons of propane and 220 gallons of flammable paint waste were found on site that have not <br /> been reported to CERS. Sodium Hydroxide Solution, Paint Striper,Thiner Solvent, and solvent Blend 1602 are <br /> below reporting thresholds and can be discarded in the chemical inventory. <br /> REGULATION GUIDANCE:Any material that meets or exceeds the reportable quantity shall be reported in the <br /> facility's business plan. <br /> CORRECTIVE ACTIONS: Immediately log into the California Environmental Reporting System (CERS)at <br /> http://cers.calepa.ca.gov/, add the materials to the hazardous material inventory, and submit to the EHD for <br /> approval. <br /> This violation has been corrected on site. <br /> This is a repeat violation, Class II. <br /> 6 HSC 25505(a)(2) Failed to electronically submit a site map with all required content. <br /> OBSERVATION: The site map is incomplete. The site map is missing locations of the emergency response <br /> equipment(fire extinguishers , eye wash, and first aid kit), loading area, emergency shut offs for power and natural <br /> gas. <br /> REGULATION GUIDANCE:A site map shall contain a north orientation, loading areas, internal roads, adjacent <br /> streets, storm and sewer drains, access and exit points, emergency shutoffs, evacuation staging areas, hazardous <br /> material handling and storage areas, and emergency response equipment. <br /> If a site map element is not applicable for your facility then list it on the map and label as"NA". <br /> CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS)at <br /> http://cers.calepa.ca.gov/, upload the correct or updated information, and submit to the EHD for approval. <br /> This is a repeat violation, Class II. <br /> FA0007083 PR0521213 SCO01 01/27/2022 <br /> EHD 19-01 Rev.9/16/2020 Page 2 of 4 Hazardous Materials Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />