Laserfiche WebLink
S A N J 0 A Q I I I Irl Environmental Health Department <br /> CCUN r <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Allspecs Muffler&Brakes 1 1004 S CHEROKEE LN, LODI January 31, 2022 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 113 HSC 25160.2(b)(3) Failed to keep copies of consolidated manifesting receipts for three years. <br /> OBSERVATION: The facility could not provide all of the consolidated manifest receipts for hazardous waste <br /> transported from the site in the past three years. The missing receipts include: <br /> -04/19/2019 for used oil <br /> -11/14/2019 for used oil <br /> -11/14/2019 for used antifreeze <br /> -11/4/2020 for used oil <br /> -11/4/2020 for used antifreeze <br /> REGULATION GUIDANCE: The generator shall retain each consolidated manifest receipt for at least three years. <br /> This period of retention is extended automatically during the course of any unresolved enforcement action regarding <br /> the regulated activity or as requested by the department or a certified unified program agency. <br /> CORRECTIVE ACTION: Locate a copy of the receipts listed above. Maintain the records on-site for three years <br /> from the date of shipping and provide a copy to the San Joaquin County Environmental Health Department(EHD). <br /> If the receipts cannot be found, provide a statement to the EHD that future receipts will be maintained on-site for <br /> three years. <br /> This is a repeat violation, Class Il. <br /> 303 CCR 66262.34(d)(2) Failed to maintain all communication or alarm systems, spill control, or decontamination <br /> equipment. <br /> OBSERVATION:A fire extinguisher at the east wall of the shop was observed with the gauge outside of the green <br /> section. <br /> REGULATION GUIDANCE:All facility communications or alarm systems,fire protection equipment, spill control <br /> equipment, and decontamination equipment,where required, shall be tested and maintained as necessary to assure <br /> its proper operation in time of emergency. <br /> CORRECTIVE ACTION: Bring the fire extinguisher into proper working order by repair, replacement or testing. <br /> Provide a corrective action statement to the San Joaquin County Environmental Health Department within 30 days. <br /> This is a Class II violation. <br /> FA0015428 PR0542616 SCO01 01/31/2022 <br /> EHD 22-01 Rev.12/06/2021 Page 4 of 6 Small Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />