Laserfiche WebLink
ABBREVIATIONS ARCHITECTURAL SYMBOL LEGEND PROJECT CONTACTS GENERAL NOTES INDEX OF SHEETS .. <br /> _ LEGEND: X- SHEET ISSUED <br /> A/C AIR CONDITIONING _ MAILING STARBUCKS COFFEE COMPANY 1. THE DRAWINGS AND PROJECT MANUAL TOGETHER CONSTITUTE THE R- SHEET ISSUED FOR REFERENCE AND COORDINATION ONLY _ <br /> ACT ACOUSTICAL CEILING TILE ADDRESS: 2401 UTAH AVENUE SOUTH CONTRACT DOCUMENTS FOR CONSTRUCTION. ALL GENERAL SEE TITLEBLOCK FOR REVISION ISSUE DATE(S) �r <br /> ADJ ADJUSTABLE 0 2 4 8 MS STOP: S-SD10 REQUIREMENTS ARE TO BE MET AND ALL MATERIALS, FINISHES AND <br /> AFF ABOVE FINISHED FLOOR N00009 SEATTLE, WASHINGTON 98134 SYSTEMS ARE TO BE INSTALLED AND PERFORM PER SPECIFICATIONS SHEET SHEET TITLE <br /> AMP AMPERE Scale:x=x (206)318-1575 UNLESS OTHERWISE NOTED. <br /> ARCH ARCHITECT <br /> NORTH GRAPHIC DATUM EXTERIOR INTERIOR DESIGN JASSICA RAMOS 2. GENERAL CONTRACTOR SHALL VISIT THE SITE, REVIEW THE BUILDING GENERAL <br /> BOH BACK OF HOUSE ARROW SCALE POINT ELEVATION ELEVATION MANAGER: STARBUCKS COFFEE COMPANY SHELL DRAWINGS AS SUBMITTED BY THE LANDLORD OR STARBUCKS 0001 GENERAL INFORMATION <br /> CALL-OUT CALL-OUT 60 SPEAR ST., 7TH FLOOR AND BECOME THOROUGHLY FAMILIAR WITH THE SITE CONDITIONS 0002 LIFE SAFETY ACCCESSIBILITY PLAN <br /> CAB CABINET SAN FRANCISCO, CA 94105 PRIOR TO CONSTRUCTION. 0003 OCCUPANCY LOAD DIAGRAM <br /> CL CENTER LINE P: (415) 361.3540 0004 ACCESSIBILITY NOTES ©2020 STARBUCKS COFFEE COMPANY <br /> CLG CEILING _ _ E: JRAMOS@STARBUCKS.COM 3. GENERAL CONTRACTOR SHALL CONSULT WITH STARBUCKS <br /> G005 ACCESSIBILITY NOTES STARBUCKS <br /> CM STARBUCKS X'XX" CONSTRUCTION MANAGER TO RESOLVE ANY CHANGES, OMISSIONS <br /> CONSTRUCTION JASON VOYER <br /> CONSTRUCTION MANAGER --- --- XX XXXX AFF � OR PLAN DISCREPANCIES PRIOR TO CONSTRUCTION. <br /> CTR CENTER MANAGER: STARBUCKS COFFEE COMPANY ARCHITECTURAL <br /> 60 SPEAR ST., 7TH FLOOR 2401 UTAH AVENUE SOUTH <br /> COUNTYST <br /> CX COMMISSIONING SECTION DETAIL SHEET ABOVE FINISH FINISH FACE TO REVISION SAN FRANCISCO, CA 94105 4. ALL WORK SHALL STATE AND FEDERAL CODES AND ORDINANCES. <br /> IN STRICT COMPLIANCE WITH A001 ARCHITECTURAL SITE PLAN SEATTLE, WASHINGTON 98134 <br /> CXA COMMISSIONING AGENT CALL-OUT CALL-OUT NOTE FLOOR FINISH FACE CLOUD P: (415) 537-7204 LOCAL, , . A001.2 ARCHITECTURAL SITE PLAN <br /> CALLOUT HEIGHT TAG DIMENSION E: JVOYER@STARBUCKS.COM A101 BUILDING FLOOR PLAN (206) 318-1575 <br /> DEG DEGREE 5. GENERAL CONTRACTOR SHALL VERIFY THE LOCATION OF ALL <br /> DET DETAIL LANDLORD: MICHAEL SINGELYN UTILITIES. A102 BUILDING FLOOR PENETRATION PLAN THESE DRAWINGS AND THE PROJECT MANUAL <br /> DIA DIAMETER MLMMA INC., A TEXAS LLC A201 BUILDING EXTERIOR ELEVATIONS ARE CONFIDENTIAL AND SHALL REMAIN THE <br /> DIM DIMENSION 9517 ALDWICH DR. 6. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS, INCLUDING A202 BUILDING EXTERIOR ELEVATIONS SOLE PROPERTY OF STARBUCKS <br /> DM STARBUCKSDALLS, TX 75238 CLEARANCES REQUIRED BY OTHER TRADES AND NOTIFY STARBUCKS A502 DRIVE THRU &SITE DETAILS CORPORATION, WHICH IS THE OWNER OF THE <br /> DESIGN MANAGER X PXXX-ES XXXX DXXXXX WXXXXX P: (310)480-8509 CONSTRUCTION MANAGER OF ANY DISCREPANCIES PRIOR TO COPYRIGHT IN THIS WORK. THEY SHALL NOT <br /> DN DOWN E: MJSINGELYN@SBCGLOBAL.NET PROCEEDING WITH THE WORK. ALL DIMENSIONS ARE TO THE FACE A503 DRIVE & SITE DETAILS BE REPRODUCED (IN WHOLE OR IN PART), <br /> REVISION PAINT DESIGN ID DOOR WINDOW OF THE FINISHED SURFACE UNLESS NOTED OTHERWISE. ALL A601 WINDOWW AND DOOR SCHEDULES & DETAILS SHARED WITH THIRD PARTIES OR USED IN ANY <br /> EA EACH TAG TAG TAG TAG TAG ARCHITECT CHRIS LEE DIMENSIONS TO BE TAKEN FROM DESIGNATED DATUM POINT. DO NOT MANNER ON OTHER PROJECTS OR <br /> EL ELEVATION OF RECORD: MCG ARCHITECTURE SCALE DRAWINGS. INTERIORS EXTENSIONS TO THIS PROJECT WITHOUT THE <br /> EQ EQUAL 15635 ALTON PKWY, SUITE 100 1101 FF& E PLAN PRIOR WRITTEN CONSENT OF STARBUCKS <br /> EXIST EXISTING IRVINE, CA 92618 7. GENERAL CONTRACTOR SHALL PATCH AND REPAIR ALL EXISTING CORPORATION. THESE DRAWINGS AND <br /> EXT EXTERIOR P: (949) 553-1117 WALLS, FLOORS, CEILINGS, OR OTHER SURFACES IDENTIFIED TO 1102 CASEWORK PLAN SPECIFICATIONS ARE INTENDED TO EXPRESS <br /> F: (949)474-7056 REMAIN THAT MAY BECOME DAMAGED DURING THE COURSE OF THE 1102.1 ENLARGED CASEWORK PLAN DESIGN INTENT FOR A PROTOTYPICAL <br /> FF&E FURNITURE, AERIAL MAP E: CLEE@MCGARCHITECTURE.COM WORK. 1103 REFLECTED CEILING PLAN STARBUCKS STORE (WHICH IS SUBJECT TO <br /> FIXTURE, AND EQUIPMENT MEP GREGORY SCHNACKEL 1104 RCP LIGHTING DIMENSION PLAN CHANGE AT ANYTIME)AND DO NOT REFLECT <br /> i"'�u''�a�l'�5 • `� 4'�""","'"'"'" <br /> FLR FLOOR 4 ,,U :0 8. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR OBTAINING 1105 INTERIOR FINISH PLAN ACTUAL SITE CONDITIONS. NEITHER PARTY <br /> FOH FRONT OF HOUSE a + - r �, CONSULTANT SCHNACKEL ENGINEERS PERMITS FOR FIRE PROTECTION, PLUMBING, MECHANICAL, AND SHALL HAVE ANY OBLIGATION NOR LIABILITY TO <br /> FOIC FURNISHED BY OWNER, 1201 INTERIOR FINISH ELEVATIONS &SCHED. <br /> . . ® ,� - ,�� OF RECORD: 1585 KAPI'OLANI BLVD. ELECTRICAL SYSTEMS PRIOR TO INSTALLATION OF SUCH SYSTEMS. THE OTHER (EXCEPT STATED ABOVE) UNTIL A <br /> INSTALLED BY CONTRACTOR HONOLULU, HI 96814 1202 INTERIOR FINISH ELEVATIONS &SCHED. <br /> t f ,� P: (808)892-3660 9. GENERAL CONTRACTOR SHALL RETAIN ONE SET OF PERMIT PLANS 1203 INTERIOR FINISH ELEVATIONS &SCHED. <br /> FO10 FURNISHED BY OWNER WRITTEN AGREEMENT <br /> PARTIES. EXECUTED BY <br /> INSTALLED BY OWNER sj �G D: (808) 829-3665 ON-SITE TO DOCUMENT ALL CHANGES MADE DURING CONSTRUCTION. 1401 RESTROOM PLAN & ELEVATIONS <br /> + E: GSCHNACKEL@SCHNACKEL_COM <br /> FT FOOT/FEET � �W ■* � 4 � � THE RECORD DRAWINGS SHALL BE ISSUED TO THE OWNER AT 1501 FLOOR FINISH DETAILS STARBUCKS TEMPLATE VERSION: 12020-01-31.1 <br /> i ` <br /> PROJECT CLOSE-OUT AS DESCRIBED IN THE GENERAL 1502 CONSTRUCTION DETAILS <br /> G GROUND ; REQUIREMENTS OF THE PROJECT MANUAL. <br /> 1503 WALL FINISH DETAILS ARCHITECT OF RECORD <br /> GC GENERAL CONTRACTOR ■ <br /> GWB GYPSUM WALLBOARD * : 10. GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING 1504 CASEWORK DETAILS <br /> i <br /> # '+ DELIVERY OF MATERIALS FROM STARBUCKS CONTRACTED THIRD 1504.1 CASEWORK DETAILS > o <br /> HC HOLLOW CORE r PARTY LOGISTICS DISTRIBUTION SERVICES AND VENDOR DIRECT 1505 CEILING DETAILSW <br /> HDW HARDWARE • # !! SHIPMENTS. SEE THE PROJECT MANUAL FOR ADDITIONAL 1601 CASEWORK AND FF&E SCHEDULES <br /> HM HOLLOW METAL INFORMATION. 1602 INTERIOR FINISHES SCHEDULES <br /> HORIZ HORIZONTAL b <br /> HR HOUR o w 11. RESPONSIBILITY FOR SUPPLY AND DELIVERY OF MATERIALS AND <br /> ,r r ELECTRICAL mcg architecure <br /> HT HEIGHT EQUIPMENT IS IDENTIFIED IN THE DRAWING SCHEDULE SHEETS <br /> HVAC HEATING, VENTILATING ' UNDER THE COLUMN LABELED "RESPONSIBILITY". E-0001 ELECTRICAL SPECIFICATIONS 15635 Alton Parkway, Suite 100, Irvine,CA 92618 <br /> AND AIR CONDITIONING -0002 ELECTRICAL SPECIFICATIONS P: 949.553.1117 F: 949.474.7056 <br /> p S 12. FOR THE PURPOSE OF THE DOCUMENTS, TO "INSTALL", SHALL MEAN E-0003 ELECTRICAL SPECIFICATIONS <br /> I.D. INSIDE DIAMETER ` ` TO PROVIDE ALL FASTENERS, MISCELLANEOUS HARDWARE, <br /> + �' 1 BLOCKING, ELECTRICAL CONNECTIONS, PLUMBING CONNECTIONS E-0004 ELECTRICAL NOTES, DETAILS, LEGENDS ARCHITECT STAMP <br /> LEED LEADERSHIP IN ENERGY a AND OTHER ITEMS REQUIRED FOR A COMPLETE AND OPERATIONAL E-1100 ELECTRICAL SITE PLAN ED A <br /> AND ENVIRONMENTAL DESIGN } � � INSTALLATION, UNLESS OTHERWISE NOTED. E-1101 POWER AND SYSTEMS PLAN GE WIN c'S'i <br /> LL LANDLORD t ' E-1102 ENLARGED ENGINE POWER&SYSTEM PLAN C <br /> LV LOW VOLTAGE ' 13. ALL ITEM SUBSTITUTIONS MUST BE APPROVED BY THE STARBUCKS LIGHTING PLAN n <br /> ` � 1 E-1103 _ � <br /> CONSTRUCTION MANAGER. E-1104 LUTRON CONTROL DIAGRAMS <br /> MAX MAXIMUM - 1839 • <br /> MEP "MECHANICAL, ELECTRICAL _ E-1105 LUTRON CONTROL DIAGRAMS <br /> AND PLUMBING" E-1106 LUTRON CONTROL DIAGRAMS �` Q <br /> MFR MANUFACTURER E-6001 PANEL SCHEDULES &ONE LINE DIAGRAM <br /> MIN MINIMUM g �� �' ` SCOPE OF WORK SITE INFORMATION E-7001 T24 ENERGY CALCULATIONS FCALIFD <br /> NIC NOT IN CONTRACT - <br /> NL NIGHT LIGHT NEW STORES. CODE AUTHORITIES: MECHANICAL <br /> NTS NOT TO SCALE * y M-0001 HVAC SCHEDULES AND SPECIFICATIONS <br /> ''- '` TENANT IMPROVEMENT OF LANDLORD DELIVERED SHELL FORA <br /> OC ON CENTER STARBUCKS COFFEE COMPANY. <br /> BUILDING CODE: 2019 CALIFORNIA BUILDING CODE M-0002 HVAC SPECIFICATIONS <br /> "`� " <br /> M-0003 HVAC SPECIFICATIONS <br /> O.D. OUTSIDE DIAMETER WORK SHALL INCLUDE INTERIOR PARTITIONS, INTERIOR FINISHES, PLUMBING CODE: 2019 CALIFORNIA PLUMBING CODE M-1101 MECHANICAL PLAN <br /> PLC PLACE VICINITY PLAN EQUIPMENT, LIGHTING, HVAC, AND RELATED. MECHANICAL CODE: 2019 CALIFORNIA MECHANICAL CODE M-1102 HVAC DETAILS <br /> 1_7 <br /> R RADIUS NO SITE WORK INCLUDED. <br /> ELECTRICAL CODE: 2019 CALIFORNIA ELECTRICAL CODE PLUMBING <br /> E REF REFERENCE <br /> P-0001 PLUMBING SPECIFICATIONS <br /> REQ`D REQUIRED . <br /> ENERGY CODE: 2019 CALIFORNIA ENERGY CODE P-0002 PLUMBING SPECIFICATIONS <br /> REV REVISION P-0003 PLUMBING SPECIFICATIONS <br /> RND ROUND FIRE CODE: 2019 CALIFORNIA FIRE CODE <br /> P-0004 PLUMBING SPECIFICATIONS <br /> SB STARBUCKS HEALTH CODE: CALIFORNIA RETAIL FOOD CODE P-1000 PLUMBING SCHEDULES = ffwnn <br /> N SC SOLID CORE P-1101 PLUMBING SUPPLY PLAN V <br /> UI SF SQUARE FEET ACCESSIBILITY CODE: 2019 CALIFORNIA BUILDING CODE &ADA P-1102 PLUMBING WASTE&VENT PLAN 06 Q <br /> O SHT SHEET <br /> O SIM SIMILAR ZONING: P-1103 PLUMBING DETAILS <br /> 06 SPEC SPECIFICATION P-1104 PLUMBING DETAILS Z <br /> SQ SQUARE PARCEL NUMBER: 086-070-46 P-1105 1 PLUMBING RISER DIAGRAMS J W 0 Q <br /> 75 P-2000 T24 ENERGY CALCULATIONS LUQ LL <br /> TEMP TEMPORARY A,. PERMITTED TYPE OF USE: RETAIL SALES AND SERVICE <br /> TYP TYPICAL <br /> IJP ElghtMil.Rd EightMIIPR SPRINKLED: N z Q (:Y) <br /> UC UNDER COUNTER cy) 0 <br /> m UNO UNLESS NOTED OTHERWISE I'i LEASABLE AREA: X W W CO <br /> X VERT VERTICAL II CONSTRUCTION TYPE: V-BO 00 00 O <br /> m VIF VERIFY IN FIELDCC <br /> U) PROPOSED USE: RETAIL SALES AND SERVICES d 0- O <br /> G <br /> O li <br /> O <br /> O <br /> RESPONSIBILITY DEFERRED SUBMITTALS: X STORE #: 65246 <br /> LEGEND —d 'agper� PROJECT #: 88584-001 <br /> ApEi.111y <br /> � <br /> s 7°� ,�o San Joaquin County ISSUE DATE: 50% CD 1-29-21 <br /> GC GENERAL CONTRACTORa z. y Environmental Health Department <br /> Q: DESIGN MANAGER: J. RAMOS <br /> U LL LANDLORD � � .� <br /> N- < 1868 E. Hazelton Ave. <br /> SB STARBUCKS - - Morada Stockton, CA 95205 PRODUCTION DESIGNER: <br /> + CHECKED BY: SKIM <br /> E WH STARBUCKS WAREHOUSE ( )3PL r' <br /> VD STARBUCKS VENDOR DIRECT (209) 468-3420 <br /> Y kA APPROVED WITH CONDITIONS Revision Schedule <br /> ) Rev Date By Description <br /> L Morada u; .o <br /> Q For conditions, please see approval letter dated: 3-19-21 <br /> ste l�anie �a�rr�ez <br /> Approved by: Date: Mar 19, 2021 <br /> 73 <br /> Q SHEET TITLE: <br /> N GENERAL INFORMATION <br /> N <br /> O <br /> SCALE: AS SHOWN <br /> No SHEET NUMBER: <br /> N <br /> N <br /> 001 <br /> N <br />