My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
10878
>
2300 - Underground Storage Tank Program
>
PR0231598
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:20 PM
Creation date
2/3/2022 3:57:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0231598
PE
2361
FACILITY_ID
FA0001146
FACILITY_NAME
MORADA CHEVRON FAST N EASY #60*
STREET_NUMBER
10878
Direction
N
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95212
APN
08607002
CURRENT_STATUS
01
SITE_LOCATION
10878 N HWY 99
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\lsauers1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
134
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br /> SAN-6-JOAQUIN <br /> I.rC O U T Time In: <br /> Time Out: <br /> r <br /> r'�JFOSX:, Careotness grows here. <br /> Underground Storage Tank Program Service Request Inspection Report <br /> Name of Facility: MORADA CHEVRON FAST N EASY#60* Date: 03/17/2022 <br /> Address: 10878 N HWY 99 , STOCKTON 95212 <br /> Requestor: MATT THOMAS, CGRS INC Telephone: (916)991-1100 <br /> Program Element: 2308-UST RETROFIT Request#: SR0084153 <br /> Inspection Type: 298-UST RETROFIT REPAIR INSPECTION <br /> Onsite Service Technician: Garrett Warren ICC Service Tech/Installer Exp. Date: 08/24/2022 <br /> Manufacturer training: <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> NOTES <br /> Per the technician,the following work was done for both 91 tanks. He stated no work was done to the 87 or diesel tanks. The <br /> diesel tank is the center of a 3-compartment split tank,with 91 tanks on either end <br /> -Replaced both 91 STP sumps,with Bravo penetrations <br /> -Resealed around the edges of all bungs in both 91 STP sumps(repaired 91/diesel/91 tank outer wall/secondary containment) <br /> -Replaced all flex piping within both 91 STP sumps <br /> -Replaced several feet of fiberglass product,vent, and vapor piping,to allow the sumps to be installed (NOV Red Thread IIA) <br /> -Replaced 91 STP sump sensors(Veeder-Root 208) <br /> -Replaced 91 leak detectors(VMI 99-LD2000) <br /> ***The approved permit did not include the product piping replacement, sensor replacement, or leak detector replacement. <br /> Submit an updated scope of work, parts list, and installation certifications for this work.*** <br /> Witnessed the following while on site: <br /> -Primary piping soap test and pressure test of both 91 product lines. Passed. <br /> -Secondary piping soap test and pressure test of both 91 product lines. Passed. <br /> -Verified 91 product piping slope. Verified pipe setbacks and burial depth. No issues were observed with the new piping. <br /> -Verified backfill. <br /> -Vacuum testing of the 91/diesel/91 split tank secondary containment. Passed. <br /> Still needed: <br /> -Secondary containment testing of both 91 STP sumps. Incon testing was planned, but could not be completed due to issues <br /> found by the tester. <br /> -Leak detector testing <br /> -Sensor functionality testing <br /> NOTE:A six month retest of both 91 STP sumps and both 91 product pipes is due September 2022. Provide 48 hours <br /> notification to the EHD when this test is scheduled. <br /> This facility is NOT approved to operate. <br /> The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br /> Safety Code.If a reinspection is required,fees will be assessed at the current hourly rate. <br /> Received by: Name and Title: Emailed to CGRS, Inc., <br /> EH Specialist: STACY RIVERA Phone: <br /> FA0001146 SR0084153 SC298 03/17/2022 <br /> EHD 23-01 Rev.06/30/15 Page 1 of 1 Underground Storage Tank Program Service Request Inspection Report <br />
The URL can be used to link to this page
Your browser does not support the video tag.