Laserfiche WebLink
i <br /> OPau-j 'a <br /> Environmental Health Department <br /> _,. =7 SAW] OAQUIN <br /> COUNTY <br /> Munia Jasjit Kang , REHS , Director <br /> a Naidu, REHS Assistant Director <br /> Greatness grows here . Pp <br /> PROGRAM COORDINATORS <br /> Robert McClellon , REHS <br /> Jeff Carruesco , REHS , RDI <br /> Willy Ng , REHS <br /> Melissa Nissim , REHS <br /> Steven Shih , REHS <br /> February 15 , 2022 Michelle Henry, REHS <br /> Liddy McKenzie <br /> Gettler- Ryan , Inc . <br /> 6805 Sierra Ct . <br /> Dublin , CA 94568 <br /> Re : Ramos Oil — French Camp SR0084835 <br /> 10842 S . Harlan Rd . , French Camp , CA 95231 <br /> The San Joaquin County Environmental Health Department ( EHD ) has completed the review of the <br /> application for a 1 hour plan check service request to do the following on the underground storage tank <br /> ( UST) system at the above noted address : <br /> • Install an electronic leak detector on the diesel tank <br /> • Cold start the monitoring panel <br /> The plan check service request has been approved with the following conditions : <br /> 1 . Contact the local fire department and the San Joaquin Valley Air Pollution Control District for <br /> any applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work . All new addenda supersede the previous ones . <br /> 3 . Provide written notification to ustslgov . orq to arrange the following repairs and testing (a 48- <br /> hour notice is required ) . Please be aware that inspections for emergency work must be <br /> scheduled within five days of permit approval . <br /> a . Sensor functionality : Functionality of the monitoring system must be verified to ensure <br /> that monitoring has been restored to meet the requirements of Title 23 California Code <br /> of Regulations and the Health & Safety Code . A copy of the alarm history shall be <br /> printed prior to performing the " cold start" of the Veeder Root system and made <br /> available at the time of EHD inspection . <br /> b . Leak detector test : Leak detector must be tested to confirm that the device can detect a <br /> leak of 3 gallons per hour at 10 psi . <br /> 4 . Any individual performing the work of a service technician must meet the following <br /> qualifications : <br /> a . Possess or be employed by a person who possesses one of several permissible valid , <br /> current contractor' s licenses issued by the Contractors State License Board ( may be <br /> issued to the installation company) , or a Tank Tester' s license issued to the individual <br /> by the State Water Board <br /> b . Possess or work under the direct and personal supervision of an individual physically <br /> present at the work site who possesses a valid , current California UST Service <br /> Technician certificate issued by the International Code Council ( ICC) <br /> 1868 E . Hazelton Avenue Stockton , California 95205 T 209 468 -3420 F 209 464-0138 1 www . sjgov . org/ehd <br />