My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
707
>
2300 - Underground Storage Tank Program
>
PR0505151
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/15/2023 8:17:51 AM
Creation date
2/8/2022 8:37:04 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0505151
PE
2361
FACILITY_ID
FA0007815
FACILITY_NAME
QUICKI KLEEN CAR WASH
STREET_NUMBER
707
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
707 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br />Overfill Prevention Equipment Inspection Report <br />6. OVERFILL PREVENTION EQUIPMENT <br />DETAILS <br />Tank ID (one OPE per column) <br />s7 <br />91 <br />DIESEL <br />Are both vent and tank riser piping <br />secondarily contained? <br />❑Yes <br />❑✓ No <br />❑Yes <br />❑✓ <br />No <br />❑Yes <br />❑✓ <br />No <br />❑Yes <br />❑ <br />No <br />OPE Model <br />oPw <br />oPw <br />oPw <br />What is the OPE response when activated? <br />(Check all that apply.) <br />❑✓ Shut off <br />Flow <br />❑Restricts <br />Flow <br />❑ Audible <br />Alarm <br />❑ Visual <br />Alarm <br />❑✓ <br />❑Restricts <br />❑Audible <br />❑Visual <br />Shut off <br />Flow <br />Flow <br />Alarm <br />Alarm <br />� <br />❑Restricts <br />❑Audible <br />❑Visual <br />Shut off <br />Flow <br />Flow <br />Alarm <br />Alarm <br />❑Shut <br />❑Restricts <br />❑Audible <br />❑Visual <br />off <br />Flow <br />Flow <br />Alarm <br />Alarm <br />Are flow restrictors installed on vent piping <br />that may interfere with the OPE operation? <br />❑Yes* <br />❑✓ No <br />❑Yes"" <br />p <br />No <br />❑Yes* <br />❑✓ <br />No <br />❑Yes* <br />❑ <br />No <br />At what level in the tank is the OPE set to <br />activate? (Inches from bottom of tank) <br />106.rJ <br />101 <br />103 <br />What is the percent capacity of the tank at <br />which the OPE activates? <br />93.8 <br />898 <br />91.3 <br />Is the OPE in proper operating condition to <br />respond when the stored substance <br />reaches the designated regulatory level? <br />❑✓ Yes <br />❑ No <br />p <br />❑ <br />Yes <br />No <br />❑✓ <br />❑ <br />Yes <br />No <br />❑Yes <br />❑ <br />No <br />7. SUMMARY OF TESTING RESULTS <br />OPE Inspection Results <br />❑✓ Pass <br />❑Fail <br />❑✓ <br />❑Fail <br />Pass <br />❑✓ <br />❑Fail <br />Pass <br />❑Pass <br />❑Fail <br />8. COMMENTS <br />Describe all results marked "Fail" and each proposed remedy. <br />* Mark here if: <br />❑ Flow restrictors interfere with overfill prevention and equipment repairs <br />required. <br />4dditional copies of this page maybe attached. <br />Attach tank chart(s), measurements, calculations, and In -Tank Setup reports) <br />Page 2 of 2 <br />