My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0081494_SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FRENCH CAMP
>
25
>
2600 - Land Use Program
>
SR0081494_SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/10/2022 9:04:11 AM
Creation date
2/10/2022 9:02:08 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SR0081494
PE
2602
FACILITY_NAME
FRENCH CAMP TRUCK TERMINAL
STREET_NUMBER
25
Direction
E
STREET_NAME
FRENCH CAMP
STREET_TYPE
RD
City
FRENCH CAMP
Zip
95336
APN
19307014
ENTERED_DATE
12/6/2019 12:00:00 AM
SITE_LOCATION
25 E FRENCH CAMP RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\tsok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PERCOLATION TEST RESULTS WITH CORRESPONDING SOIL TYPE, <br />PERCOLATION RATE AND APPLICATION RATE IN GALLONS / FT2 / DAY <br />36 INCH DEEP PERC TEST BORING 83.3 min/inch / 0.123 gallons/ft2 /day <br />SANDY CLAY LOAM <br />96 INCH DEEP PERC TEST BORING 4.8 min/inch / 1.200 gallons/ft2 /day <br />LOAMY SAND <br />I-NLS§ 3.3, SSS§ 5.3, 5.4. Table 1 below summarizes the analyzed soil physical and chemical <br />characteristics from the retrieved soil sample: <br />TABLE 1 <br />SOIL PROFILE CHARACTERISTICS AND <br />ANALYTICAL TEST RESULTS <br />SAMPLE I.D. DEPTH <br />, <br />SOIL TEXTURE <br />CLASSIFICATION <br />SOIL NITRATE- <br />NITROGEN CONTENT <br />pH AND <br />CATION EXCHANGE CAPACITY <br />In meq/100g <br />3 FT DEPTH Sandy Clay Loam <br />(CL, SC) <br />4 ppm NO,-N 8.6 20.0 meq/100g <br />8 FT DEPTH Loamy Sand <br />(ML, SM) <br />12 ppm NO,-N 8.3 7.9 meq/100g <br />C. PERCOLATION TEST RESULTS <br />SSS§ 6.2. The aforementioned percolation test borings were completed in the location depicted on <br />the attached Site Plan to assess the permeability of the disposal area soils. <br />SSS§ 6.3. After drilling the shallow test boring, the sidewalls were scored with a pry-bar to open <br />potentially smeared sidewalls. The deep 8 ft boring was not scored due to the soil structure. Two <br />inches of fine gravel was placed at the bottom and three-inch dia. perforated PVC pipe was inserted <br />in each test boring. After drilling, the test borings were pre-saturated with 12 inches of water, 24 hrs <br />prior to the start of testing. Maximum soil saturation conditions were achieved to determine the <br />saturated permeability of the two different soil structures encountered. <br />SSS§ 6.4, 6.5. On October 11, 2019, percolation testing commenced at 0730 hrs. No standing <br />water was observed after the 24-hr soak period in either boring. Consequently, EHD Perc Test <br />Procedure #2 was conducted whereby testing was done over a four-hour period with readings taken <br />every 30 minutes. <br />A summary of the perc test results with corresponding application rates in gallons of effluent <br />accepted per square foot of soil per day are illustrated in Table 2. The corresponding application rate <br />was obtained from Page 24 of the OWTS Policy - Water Quality Control Policy for Siting. Design, <br />Operation, and Maintenance of Onsite Wastewater Treatment Systems. <br />TABLE 2 <br />3 <br />Chesney Consulting
The URL can be used to link to this page