UL/ ULC Listed Red Thread® IIA Piping System <br /> MENOMONIE <br /> Lowest Total Cost Ownershipt <br /> Benefits of [Material Cost + Installation Cost] - System Life <br /> 1 Maintenance cost and replacement cost not required with RED THREAD IIA piping system . <br /> Fiberglass Piping Thirty Year Outstanding Corrosion <br /> in Underground ` ' W— a r r a n t y * Resistance — RED THREAD IIA <br /> With over 40 piping systems resist internal and <br /> Fuel Applications 4 years proven external corrosion from hazardous <br /> _ performance in soils , fuels and other corrosive <br /> TIME TESTED the marketplace , fluids . <br /> Underwriter ' s <br /> • 304earWarranty Laboratories , Inc . Quality Assurance — FGS <br /> and Underwriter ' s Laboratories Smith Fibercast quality assurance <br /> • Installed since 1964 Canada ( UL / ULC ) Listed RED procedures meet or exceed the <br /> THREAD IIA pipe , fittings and test requirements of UL/ULC . <br /> adhesive carry a 30 -year warranty. <br /> • Never been removed due The product is warranted to be Permeability — RED THREAD <br /> to fuel incompatibility free from defects in material and IIA permeability resistance <br /> workmanship—and against internal greatly exceeds UL allowable <br /> • Total immersion testing and external corrosion—when used permeability. <br /> in fuels for underground transportation of <br /> fuels . 2004 UL 971 : <br /> Primary - 1 gm/m2/day <br /> • Case History G7301 Leak Prevention — Sump (0 . 053 gal/ 100 ft . of 2" pipe , <br /> entry/termination fittings provide 30 days ) <br /> positive seal at the sump to help Secondary - 4 gm/m2/day <br /> ( 0 . 213 gal/ 100 ft . of 2pipe , <br /> LOWEST TOTAL COST prevent leaking of underground " <br /> OF OWNERSHIP fuel in or out of the sump . This 30 days ) <br /> fitting also helps provide Class 1995 UL 971 : <br /> • No reinstall costs due I ( leak prevention ) protection Primary 111 4 gm /m2/day <br /> to fuel incompatibility which complies with California ' s ( 0 . 213 gal / 100 ft . of 2 " pipe , <br /> requirement for continuous 30 days ) <br /> interstitial monitoring of the piping Secondary - 24 gm/m2/day <br /> • Homogenous system : no ( 1 . 278 gal/100 ft . of 2" pipe , <br /> liner, no bladder systems secondary containment . 30 days ) <br /> • Exceptional Flow <br /> ATRUE PIPE INAPIPE Characteristics - Two - inch <br /> RED THREAD IIA pipe has the <br /> • Interstitial space largest I . D . (2 . 235" ) in the fueling ' <br /> communication industry—allowing you to sell twice <br /> the fuel per foot than any 11 /2 " <br /> • Leak prevention , not flexible product on the market . <br /> leak detection Three - inch RED THREAD IIA <br /> fiberglass pipe has a nominal 3 . 36 Old vs New "o Pipe in the foreground was <br /> installed in 1973 and removed 27 years <br /> • INSTALL IT, BURY IT, I . D . ; four-inch pipe has a 4 . 36 " I . D . later when the station closed. <br /> FORGET IT! <br /> ' Please review FGS Smith Fibercast's written warranty to determine the terms and conditions . <br /> 2 <br />