My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COLONY
>
1553
>
2300 - Underground Storage Tank Program
>
PR0516526
>
INSTALL_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/5/2023 11:41:58 AM
Creation date
2/10/2022 9:06:58 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2022
RECORD_ID
PR0516526
PE
2351
FACILITY_ID
FA0012659
FACILITY_NAME
LOVES COUNTRY STORES OF CALIFORNIA #223
STREET_NUMBER
1553
STREET_NAME
COLONY
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
24534024
CURRENT_STATUS
01
SITE_LOCATION
1553 COLONY RD
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
356
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UL/ ULC Listed Red Thread® IIA Piping System <br /> RED THREAD IIA PIPING RED THREAD IIA <br /> RED THREAD IIA Primary Piping Secondary Containment Piping <br /> Nom . Pipe Size Part Number Pipe Length Nom . Pipe Size Part Number Pipe Length <br /> ( In .) mm (ft •) ( In .) mm (ft•) <br /> 2 50 011020-069 - 1 15 3 80 011030-0694 15 <br /> 2 50 011020-069-2 22-25 3 80 011030-069-5 22-25 <br /> 2 50 011020-069 -3 26 -30 3 80 011030-069-6 26-30 <br /> 3 1 80 011030-069 - 1 15 4 100 011040-077-5 15 <br /> 3 80 011030 -069-2 22-25 4 100 011040-069-5 22-25 <br /> 3 80 011030-069 -3 26 -30 4 100 011040-077-6 26-30 <br /> 4 100 011040-071 - 1 15 6 150 011060- 120-5 15 <br /> 4 100 011040-069-2 22-25 6 150 011060- 1204 22-25 <br /> 4 100 011040-071 -3 26-30 6 150 011060- 120-6 26-30 <br /> DIMENSIONAL DATA <br /> Nominal External Pressure <br /> Nominal Wall Max. Rating <br /> Nominal Nominal Thickness Nominal Pressure/ Mill Test (psig/MPa <br /> Pipe I . D . O . D . Weight Temperature Pressure <br /> Size ( In .l ( In ./mm ) (In ./mm ) ( In /mm ) ( Ibs .lftAg -m ) Max. Rating (psig /MPa) <br /> mm) Thickness 75° F/240C 150° F/660C <br /> ( In ./mm) <br /> 2 2 . 235 2 . 375 1 . 070 0 . 5 250 psig @ 150 ° F 375 85 80 <br /> 50 57 61 1 . 78 0 . 74 1 . 72 MPa @ 66 ° C 2 . 59 . 57 . 55 <br /> 3 3 .360 3 . 500 .070 0 . 7 175 psig @ 150 ° F 300 36 34 <br /> 80 85 90 2054 1 . 04 1 . 21 MPa @ 66 ° C 1 2007 . 25 . 23 <br /> 4 4 . 360 4 . 560 . 085 1 . 2 125 psig @ 150 ° F 265 34 30 <br /> 100 111 116 2 . 16 1 . 79 0 . 86 MPa @ 66 ° C 1 . 83 . 23 . 21 <br /> PROPERTY RED THREAD IIA Pipe Bending Radius, Minimum <br /> psi @ 75° F MPa @ 24° C psi @ 150° F MPa @ 66°C Nominal <br /> Axial Tensile (ASTM D2105) Pipe Size 2" 3" 4" 6" <br /> Ultimate Stress 10, 300 71 . 0 81200 56 . 5 (inches) <br /> Design Stress 2 , 575 17 . 8 21050 14 . 1 Ft. 75 110 140 204 <br /> Modulus of Elasticity 1 .82 x 106 12548 1 .42 x 106 9791 <br /> 'm1'21 . 3 I 33 .5 142 .7 162 .21 <br /> Axial Compression (ASTM D695) (1 ) All values except pressure-temperature <br /> Ultimate Stress 33 ,300 230 . 0 25 , 600 177 .0 maximum rating are nominal values. Tolerances <br /> Design Stress 81300 57 . 2 61400 44 . 1 or maximum/minimum limits can be obtained <br /> Modulus of Elasticity 1 . 26 x 106 8687 . 89 x 106 6136 from Smith Fibercast. <br /> (2) All sizes can accept full vacuum pressures <br /> Beam Bending (SFPTM ) at maximum temperature ratings . <br /> Ultimate Stress 23 , 000 159 . 0 19 , 200 132 . 0 (3) Ultimate and allowable design stresses are <br /> Design Stress(4) 29900 20 . 0 21400 16 . 5 based on minimum reinforced wall thickness. <br /> Modulus of Elasticity 2 . 18 x 106 15031 1 .70 x 106 11721 D2996 manufactured in compliance with ASTM <br /> (Long Term per ASTM D2925) (4) Design bending stress is 1 /8 of ultimate to <br /> Hydrostatic Burst (ASTM D1599 ) account for combined stress (i .e. bending and <br /> pressure). <br /> Ultimate Hoop (5) Design stress is based on long term cyclic <br /> Tensile Stress 34 , 000 1 234 39 , 200 271 fatigue data using ASTM D2992 test method . <br /> Hydrostatic Design (ASTM D2992) 2"-3" 2" & 3" 2" & 3" 2" & 3" However, all testing is not complete at time of <br /> Procedure 9 ,410(5) 64 . 9(5) 71400(7) 51 (8) printing . <br /> (6) For RED THREAD IIA pipe the hydrostatic <br /> Cyclic 150 x 106 4"-6" 4"-6" 4"-6" 4"-6" cyclic design stress was determined at 1500 and <br /> Cycles 13 , 040(6) 89 . 9(6 ) 10 ,450 72 . 1 200° F, per ASTM D2992 Procedure A. Based <br /> on this data, the extrapolated value at 75°F is <br /> Coefficient of Linear 0 .88 x 10-5 in ./in ./° F 13,030 psi . <br /> Thermal Expansion (SFPTM ) 1 . 58 x 10-5mm/mm/° C (7) For RED THREAD IIA pipe the hydrostatic <br /> Specific Gravity 1 ,8 cyclic design stress was determined at 750 and <br /> 200° F, per ASTM D2992 Procedure A. Based <br /> Flow Factor on this data, the extrapolated value at 150° F is <br /> Hazen-Williams Coefficient 150 7,400 psi . <br /> 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.